Template:FMB Device Family Trip/Odometer Parameter list

Trip scenario parameters

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11800 Uint8 0 0 3 0 – Disable Scenario settings
1 – Low priority
2 – High priority
3 – Panic priority
11801 Uint8 1 0 1 0 – Disable Eventual records
1 – Enable
11802 Uint8 0 0 1 0 – Continuous Mode
1 – Between records
11803 Uint8 5 0 255 km/h Start speed
11804 Uint16 60 0 65535 Seconds Ignition off timeout
7031 Uint8 0 0 10 Phone number Send SMS to
8031 String "Trip" 0 160 Text Sms text

Advanced trip scenario parameters


Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
700 Uint16 100 0 65535 0 – Disable Eco score allowed events
11805 Uint8 0 0 1 0 – Disable Remember iButton
1 – Enable

Odometer parameters


Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11806 Uint8 0 0 2 0 – GNSS Calculation source
1 – OBD
2 – LVCAN
11807 Uint32 0 0 4294967 Kilometer Odometer Value