Power Consumption configuration descriptions

From Teltonika Telematics Wiki

12V Normal mode

Configuration:

  • Movement Source: Ignition
  • Battery charge: After Ignition ON.
  • Sleep setting: Disabled
  • Ignition source: DIN1 or power voltage low level ignition must be turned off (low)
  • GPRS Context: Disabled
  • Fota WEB settings: Disabled
  • Min Period: 3600
  • Min Saved Records: 1
  • Send Period: 3600
  • Disable all features.
  • Disable Bluetooth.
  • I/O:Default


12V save/send every 1s 2G

Configuration:

  • Movement Source: Ignition
  • Battery charge: After Ignition ON.
  • Sleep setting: Disable
  • Ignition source: DIN1 or power voltage low level ignition must be turned off(low)
  • GPRS Context:Enable
  • Fota WEB settings: Disable
  • Min Period: 1
  • Min Saved Records: 1
  • Send Period: 1
  • Disable all features.
  • Disable bluetooth.
  • I/O:Default


12V save/send every 1s 4G

Configuration:

  • Movement Source: Ignition
  • Battery charge: After Ignition ON.
  • Sleep setting: Disable
  • Ignition source: DIN1 or power voltage low level ignition must be turned off(low)
  • GPRS Context:Enable
  • Fota WEB settings: Disable
  • Min Period: 1
  • Min Saved Records: 1
  • Send Period: 1
  • Disable all features.
  • Disable bluetooth.
  • I/O:Default


12V save/send every 30s 4G

Configuration:

  • Movement Source: Ignition
  • Battery charge: After Ignition ON.
  • Sleep setting: Disable
  • Ignition source: DIN1 or power voltage low level ignition must be turned off(low)
  • GPRS Context:Enable
  • Fota WEB settings: Disable
  • Min Period: 30
  • Min Saved Records: 1
  • Send Period: 30
  • Disable all features.
  • Disable bluetooth.
  • I/O:Default


4V Normal mode

4V save/send every 1s 2G

4V save/send every 1s 4G

4V save/send every 30s 4G