Jump to content

TEST-T

From Teltonika Telematics Wiki
PARAMETER NAME PARAMETER ID (RELATED AVL ID) DESCRIPTION VALUES
Scenario Settings 11200
(251)
Sets the scenario priority level.

0 = Disable Disable scenario.
1 = Low priority Device makes an additional record with indication of event cause.
2 = High priority Device makes an additional record with high priority flag and immediately sends an event packet to the server by GPRS.
3 = Panic priority Triggers the same actions as high priority, but if GPRS fails, the device sends an AVL packet via SMS (if enabled in SMS settings).

Eventual Records 11203 Toggle appending scenario status to eventual records. 0 = Disable When enabled, scenario status will be appended only to eventual records.
1 = EnableWhen disabled, scenario status will be appended in each AVL record.
Delay To Enter Idle (s) 11205 Delay before entering the excessive idling state. Defines how long a vehicle with Ignition ON (configured in System>Ignition settings) should not move to enter the excessive idling state. Minimum value = 0
Maximum value = 3600
Delay To Exit Idle (s) 11206 Delay before exiting the excessive idling state. Defines how long a vehicle should be moving with Ignition ON (configured in System>Ignition settings) to exit the excessive idling state. Minimum value = 0
Maximum value = 3600
Output Control 11024 Configures the digital output to be activated when this scenario is entered. 0 = None DOUTs are disabled in this scenario.

1 = DOUT1 DOUT1 is enabled in this scenario.
2 = DOUT2 DOUT2 is enabled in this scenario.
3 = DOUT3 DOUT3 is enabled in this scenario.

DOUT ON Duration (ms) 11201 Duration for which the selected DOUT signal is ON when the device enters this scenario. Value in milliseconds.

Works together with "DOUT OFF Duration" (for most parameters) - after one duration elapses, the other starts, until the scenario is exited.

Minimum value = 100
Maximum value = 5000
DOUT OFF Duration (ms) 11202 Duration for which the selected DOUT signal is OFF when the device enters this scenario. Value in milliseconds.

Works together with "DOUT ON Duration" - after one duration elapses, the other starts, until the scenario is exited.

Minimum value = 0
Maximum value = 5000
Buzzer 11209 Toggles use of buzzer for event indication.

This parameter is available only for devices with integrated buzzer. In such cases, it replaces the “Output control” and related parameters.

0 = None Buzzer is disabled for this scenario.
1 = Buzzer Buzzer is enabled for this scenario.
Send SMS to 7037 Sets the GSM number of SMS event recipient. Number selected from “GSM Predefined Numbers” list in menu “SMS / Call Settings”.
SMS Text 8037 Sets the SMS text that will be sent to SMS recipient when the event is triggered. Maximum text length = 160 symbols