Jump to content

TEST-X

From Teltonika Telematics Wiki
PARAMETER NAME PARAMETER ID (RELATED AVL ID) DESCRIPTION VALUES
Auto geofence 1017500 Disables, or enables and sets priority for record generation. 0' = Disable Disable scenario.

1 = Low priority Device makes an additional record with indication of event cause.

2 = High priority Device makes an additional record with high priority flag and immediately sends an event packet to the server by GPRS.
Generate event 20001 Defines when the event will be generated 0 = On exit

1 = On enter
2 = On both

Activation timeout (s) 20002 Sets the duration in seconds for two conditions:

1. In Wait State: how long the vehicle must be stationary with a GNSS fix before the geofence is armed.
2. In Active State: how long the vehicle must be moving without a GNSS fix to trigger an alarm.

Minimum value = 0
Maximum value = 65535
Radius (m) 20003 Sets the radius of the circular geofence in meters, measured from the vehicle's position when armed. inimum value = 0
Maximum value = 1000000
Deactivate by 20004 Selects the source that will deactivate an armed geofence and return the system to the Wait State. 0 - Power Voltage: Deactivates if external voltage exceeds a predefined threshold.

1 = Digital Input 1: Deactivates if DIN1 becomes active.
2 = Digital Input 2: Deactivates if DIN2 becomes active.
3 = Digital Input 3: Deactivates if DIN3 becomes active.
4 = iButton: Deactivates if an authorized iButton is presented.