From Teltonika Telematics Wiki
Mobile network
Mobile data settings
Auto APN
| Parameter ID |
Parameter Type |
Default value |
Value range |
Value |
Parameter name |
| Min |
Max |
| 2025 |
Uint8 |
0 |
0 |
1 |
0 – Disable |
Auto APN |
| 1 – Enable |
SIM 1 Settings
| Parameter ID |
Parameter Type |
Default value |
Value range |
Value |
Parameter name |
| Min |
Max |
| 2000 |
Uint8 |
1 |
0 |
1 |
0 – Disable |
SIM 1 |
| 1 – Enable |
| 2001 |
Char |
"" |
0 |
32 |
String |
APN |
| 2002 |
Char |
"" |
0 |
32 |
String |
APN username |
| 2003 |
Char |
"" |
0 |
32 |
String |
APN password |
| 2090 |
Uint8 |
1 |
1 |
3 |
1 – IPv4 |
PDP Context Type |
| 2 – IPv6 |
| 3 – IPv4v6 |
| 2016 |
Uint8 |
0 |
0 |
2 |
0 – Disable |
GPRS authentication |
| 1 – Normal (PAP) |
| 2 – Secured (CHAP) |
Server Settings
Primary server settings
| Parameter ID |
Parameter Type |
Default value |
Value range |
Value |
Parameter name |
| Min |
Max |
| 2004 |
Char |
"" |
0 |
55 |
String |
Domain |
| 2005 |
Uint16 |
0 |
0 |
65535 |
Number |
Port |
| 2006 |
Uint8 |
0 |
0 |
3 |
0 – TCP |
Data protocol |
| 1 – UDP |
Secondary server settings
| Parameter ID |
Parameter Type |
Default value |
Value range |
Value |
Parameter name |
| Min |
Max |
| 2010 |
Uint8 |
0 |
0 |
2 |
0 – Disable |
Secondary server mode |
| 1 – Duplicate |
| 2 – Backup |
| 2007 |
Char |
"" |
0 |
55 |
String |
Domain |
| 2008 |
Uint16 |
0 |
0 |
65535 |
Number |
Port |
| 2009 |
Uint8 |
0 |
0 |
3 |
0 – TCP |
Data protocol |
| 1 – UDP |
Server communication settings
| Parameter ID |
Parameter Type |
Default value |
Value range |
Value |
Parameter name |
| Min |
Max |
| 1000 |
Uint32 |
300 |
30 |
259200 |
Seconds |
Open link timeout |
| 1001 |
Uint16 |
30 |
5 |
300 |
Seconds |
Response timeout |
| 1003 |
Uint16 |
0 |
0 |
300 |
Seconds |
Keep-alive |
| 1009 |
Uint8 |
0 |
0 |
1 |
0 – Disable |
Permanent link |
| 1 – Enable |
Network settings
| Parameter ID |
Parameter Type |
Default value |
Value range |
Value |
Parameter name |
| Min |
Max |
| 2100 |
Uint8 |
0 |
0 |
1 |
0 – Auto |
Network mode |
| 1 – 2G |
| 2 – 4G |
FOTA WEB settings
| Parameter ID |
Parameter Type |
Default value |
Value range |
Value |
Parameter name |
| Min |
Max |
| 13003 |
Uint8 |
1 |
0 |
1 |
0 - Disable |
FOTA WEB Settings |
| 1 – Enable |
| 13000 |
Char |
service.fota.teltonika.lt |
0 |
55 |
String |
Server domain |
| 13001 |
Uint16 |
5005 |
0 |
65535 |
Number |
Server port |
| 13005 |
Char |
ping.fota.teltonika.lt |
0 |
55 |
String |
Ping domain |
| 13004 |
Uint16 |
5055 |
0 |
65535 |
Number |
Ping port |
Network operators settings
| Parameter ID |
Parameter Type |
Default value |
Value range |
Value |
Parameter name |
| Min |
Max |
| 5000-5049 |
Uint32 |
0 |
0 |
999999 |
Number |
SIM 1 roaming network operators list |
| 5500-5549 |
Uint32 |
0 |
0 |
999999 |
Number |
SIM 1 blacklist network operators list |
| 5550-5599 |
Uint32 |
0 |
0 |
999999 |
Number |
SIM 1 forbidden network operators list |
| 2018 |
Uint8 |
0 |
0 |
1 |
0 – Disable |
Ban list control |
| 1 – Enable |
System parameters
GNSS settings
| Parameter ID |
Parameter Type |
Default value |
Value range |
Value |
Parameter name |
| Min |
Max |
| 121 |
Uint8 |
10 |
1 |
15 |
1 – GPS |
GNSS source |
| 3 – GPS, GLONASS |
| 5 – GPS, Galileo |
| 9 – GPS and BeiDou |
| 15 – GPS, GLONASS, Galileo and BeiDou |
Power saving settings
| Parameter ID |
Parameter Type |
Default value |
Value range |
Value |
Parameter name |
| Min |
Max |
| 102 |
Uint8 |
0 |
0 |
5 |
0 – Disable |
Power saving mode |
| 3 – Online sleep |
| 5 – Power off sleep |
Time synchronization settings
| Parameter ID |
Parameter Type |
Default value |
Value range |
Value |
Parameter name |
| Min |
Max |
| 901 |
Uint8 |
3 |
0 |
24 |
Hours |
NTP resync |
| 902 |
Char |
"pool.ntp.org" |
0 |
55 |
String |
NTP server 1 |
| 903 |
Char |
"time.google.com" |
0 |
55 |
String |
NTP server 2 |
Battery settings
Power Bank Support
| Parameter ID |
Parameter Type |
Default value |
Value range |
Value |
Parameter name |
| Min |
Max |
| 110 |
Uint8 |
0 |
0 |
1 |
0 – OFF |
Power Bank Support |
| 1 –ON |
Location settings
| Parameter ID |
Parameter Type |
Default value |
Value range |
Value |
Parameter name |
| Min |
Max |
| 128 |
Uint8 |
0 |
0 |
1 |
0 – GNSS |
Location source |
| 1 – LBS |
LED indication
| Parameter ID |
Parameter Type |
Default value |
Value range |
Value |
Parameter name |
| Min |
Max |
| 108 |
Uint8 |
1 |
0 |
1 |
0 – Disable |
LED Indication |
| 1 – Enable |
Time zone settings
| Parameter ID |
Parameter Type |
Default value |
Value range |
Value |
Parameter name |
| Min |
Max |
| 11839 |
Uint8 |
0 |
-720 |
840 |
-720 – GMT-12:00 |
Time zone |
| -690 – GMT-11:30 |
| -660 – GMT-11:00 |
| -630 – GMT-10:30 |
| -600 – GMT-10:00 |
| -570 – GMT-09:30 |
| -540 – GMT-09:00 |
| -510 – GMT-08:30 |
| -480 – GMT-08:00 |
| -450 – GMT-07:30 |
| -420 – GMT-07:00 |
| -390 – GMT-06:30 |
| -360 – GMT-06:00 |
| -330 – GMT-05:30 |
| -300 – GMT-05:00 |
| -270 – GMT-04:30 |
| -240 – GMT-04:00 |
| -210 – GMT-03:30 |
| -180 – GMT-03:00 |
| -150 – GMT-02:30 |
| -120 – GMT-02:00 |
| -90 – GMT-01:30 |
| -60 – GMT-01:00 |
| -30 – GMT-00:30 |
| 0 – GMT+00:00 |
| 30 – GMT+00:30 |
| 60 – GMT+01:00 |
| 90 – GMT+01:30 |
| 120 – GMT+02:00 |
| 150 – GMT+02:30 |
| 180 – GMT+03:00 |
| 210 – GMT+03:30 |
| 240 – GMT+04:00 |
| 270 – GMT+04:30 |
| 300 – GMT+05:00 |
| 330 – GMT+05:30 |
| 360 – GMT+06:00 |
| 390 – GMT+06:30 |
| 420 – GMT+07:00 |
| 450 – GMT+07:30 |
| 480 – GMT+08:00 |
| 510 – GMT+08:30 |
| 540 – GMT+09:00 |
| 570 – GMT+09:30 |
| 600 – GMT+10:00 |
| 630 – GMT+10:30 |
| 660 – GMT+11:00 |
| 690 – GMT+11:30 |
| 720 – GMT+12:00 |
| 750 – GMT+12:30 |
| 780 – GMT+13:00 |
| 810 – GMT+13:30 |
| 840 – GMT+14:00 |
Button settings
Button parameter list can be found here.
Tracking settings
Records settings
| Parameter ID |
Parameter Type |
Default value |
Value range |
Value |
Parameter name |
| Min |
Max |
| 107 |
Uint8 |
2 |
0 |
2 |
0 – After position fix |
Saving sending mode |
| 1 – Always |
| 2 – After time sync |
| 1010 |
Uint8 |
120 |
0 |
86400 |
|
GNSS position fix search timeout (s)
|
|
|
| 1002 |
Uint8 |
0 |
0 |
1 |
0 – Newest |
Sort by |
| 1 – Oldest |
| 1004 |
Uint8 |
1 |
0 |
1 |
0 – TCP/IP |
Server confirmation method |
| 1 – AVL |
| 113 |
Uint8 |
1 |
1 |
1 |
1 – Codec 8 Extended |
Data Protocol |
Asset tracking modes
Asset tracking modes can be found here.
Records schedule
| Parameter ID |
Parameter Type |
Default value |
Value range |
Value |
Parameter name |
| Min |
Max |
| 35100-35105 |
Char |
"" |
0 |
23:59 |
String |
Sunday (Time 1 - Time 6) |
| 35200-35205 |
Char |
"" |
0 |
23:59 |
String |
Monday (Time 1 - Time 6) |
| 35300-35305 |
Char |
"" |
0 |
23:59 |
String |
Tuesday (Time 1 - Time 6) |
| 35400-35405 |
Char |
"" |
0 |
23:59 |
String |
Wednesday (Time 1 - Time 6) |
| 35500-35505 |
Char |
"" |
0 |
23:59 |
String |
Thursday (Time 1 - Time 6) |
| 35600-35605 |
Char |
"" |
0 |
23:59 |
String |
Friday (Time 1 - Time 6) |
| 35700-35705 |
Char |
"" |
0 |
23:59 |
String |
Saturday (Time 1 - Time 6) |
Features
Other features
Static navigation
| Parameter ID |
Parameter Type |
Default value |
Value range |
Value |
Parameter name |
| Min |
Max |
| 106 |
Uint8 |
1 |
0 |
1 |
0 – Disable |
Static navigation |
| 1 – Enable |
SMS / Call settings
SMS Security
| Parameter ID |
Parameter Type |
Default value |
Value range |
Value |
Parameter name |
| Min |
Max |
| 3004 |
Char |
"" |
0 |
5 |
String |
Password |
Input / output (I/O)