Jump to content

TEST-DM

From Teltonika Telematics Wiki

Parameter list (short)

PARAMETER ID NAME VALUE/UNITS DESCRIPTION
empty empty empty empty
900007 Speed limit km/h
Min=0
Max=1000
Default="0"
Speed threshold which determines when to generate speeding start/stop events.
900009 Activation timing 1=Outside
2=Inside
3=Outside and inside
Select Activation timing when the event will be triggered.
Control mode - Persistent:
  • Outside activation timing, selected DOUT will start being controlled while the device is outside of the geozone and will stop being controlled while the device is inside of the geozone. If the device is outside of multiple geozones, selected DOUT will continue being controlled until the device enters one of the geozones.
  • Inside activation timing, selected DOUT will start being controlled while the device is inside the geozone and will stop being controlled while the device is outside of the geozone. If Output control according to speed limit is set, selected DOUT will start being controlled while the device is exceeding the speed limit inside the geozone. If the device is inside multiple geozones, selected DOUT will continue being controlled until the device is outside of all geozones (or stops exceeding the speed limit, if configured).

Control mode - Event:

  • Outside activation timing, selected DOUT will be triggered once you exit the configured geozone.
  • Inside activation timing, selected DOUT will be triggered once you enter the configured geozone.
  • With Outside and Inside activation timing, both described logics will be applied.

Parameter list (full)

PARAMETER ID NAME VALUE/UNITS DESCRIPTION TYPE MIN MAX DEFAULT
empty empty empty empty empty empty empty empty
900007 Speed limit km/h Speed threshold which determines when to generate speeding start/stop events. Uint16 0 1000 0
DOUT1= 899901
DOUT2=899911
DOUT3=899921
Output control according to speed limit 1=Outside
2=Inside
3=Outside and inside
Select Activation timing when the event will be triggered.
Control mode - Persistent:
  • Outside activation timing, selected DOUT will start being controlled while the device is outside of the geozone and will stop being controlled while the device is inside of the geozone. If the device is outside of multiple geozones, selected DOUT will continue being controlled until the device enters one of the geozones.
  • Inside activation timing, selected DOUT will start being controlled while the device is inside the geozone and will stop being controlled while the device is outside of the geozone. If Output control according to speed limit is set, selected DOUT will start being controlled while the device is exceeding the speed limit inside the geozone. If the device is inside multiple geozones, selected DOUT will continue being controlled until the device is outside of all geozones (or stops exceeding the speed limit, if configured).

Control mode - Event:

  • Outside activation timing, selected DOUT will be triggered once you exit the configured geozone.
  • Inside activation timing, selected DOUT will be triggered once you enter the configured geozone.
  • With Outside and Inside activation timing, both described logics will be applied.
Uint16 -123456789 123456789 123456789