PARAMETER ID NAME DESCRIPTION UNITS/VALUES TYPE MIN MAX DEFAULT
11816 Private mode deactivation triggers Private mode deactivation triggers. When a trigger is activated it deactivates the private mode. Implemented using bit mask so that multiple choices could be selected. 0 - no trigger;
1 - Towing detected;
2 - Unplug detected;
3 - Towing or Unplug detected;
4 - Crash detected;
5 - Towing or Crash detected;
6 - Unplug or Crash detected;
7 - Towing, Unplug or Crash detected;
8 - Autogeofence triggered;
9 - Towing or Autogeofence triggered;
10 - Unplug or Autogeofence triggered;
11 - Towing, Unplug or Autogeofence triggered;
12 - Crash or Autogeofence triggered;
13 - Towing, Crash or Autogeofence triggered;
14 - Unplug, Crash or Autogeofence triggered;
15 - Towing, Unplug, Crash or Autogeofence triggered
Uint16 0 15 15
900007 Speed limit Speed threshold which determines when to generate speeding start/stop events. km/h Uint16 0 1000 0
1024900 Network jamming detection The feature detects GSM jamming, initiates actions using an output, and helps to prevent vehicle theft when jamming devices are used. A low signal level is not equal to GSM jamming, the device recognizes these events. 0 = Disable;
1 = Low priority;
2 = High priority
Uint8 0 2 0
899901 (DOUT1)
899911 (DOUT2)
899921 (DOUT3)
Activation timing Select Activation timing when the event will be triggered.
Control mode - Persistent:
  • Outside activation timing, selected DOUT will start being controlled while the device is outside of the geozone and will stop being controlled while the device is inside of the geozone. If the device is outside of multiple geozones, selected DOUT will continue being controlled until the device enters one of the geozones.
  • Inside activation timing, selected DOUT will start being controlled while the device is inside the geozone and will stop being controlled while the device is outside of the geozone. If Output control according to speed limit is set, selected DOUT will start being controlled while the device is exceeding the speed limit inside the geozone. If the device is inside multiple geozones, selected DOUT will continue being controlled until the device is outside of all geozones (or stops exceeding the speed limit, if configured).

Control mode - Event:

  • Outside activation timing, selected DOUT will be triggered once you exit the configured geozone.
  • Inside activation timing, selected DOUT will be triggered once you enter the configured geozone.
1=Outside
2=Inside
Uint8 1 2 1

AVL ID list

Rules:

  • Avoid inline formatting
  • For DESCRIPTION, if there are multiple items - separate them by <br>
  • Do not leave cells empty - write "-" if there is no value
AVL ID NAME BYTES TYPE MIN MAX MULTIPLIER UNITS DESCRIPTION
16 Total Odometer 4 Unsigned 0 2147483647 - m Virtual odometer value
69 GNSS Status 1 Unsigned 0 3 - - 0 - GNSS OFF;
1 - GNSS ON with fix;
2 - GNSS ON without fix;
3 - GNSS sleep
181 GNSS PDOP 2 Unsigned 0 500 - m GNSS position dilution of precision. Normal PDOP is below 3 – the lower the number, the more accurate reported location is.
13377 Neighbouring Cell 2 RSSI 1 Unsigned 0 63 - dB Signal strength of Cell #2. Included in records as Permanent I/O when LBS mode is configured as "Location Source".
157 Manual Geofence Speeding event 1 Unsigned 0 1 - - 0 - Speeding stop event;
1 - Speeding start event

Pinout

Rules:

  • Avoid inline formatting, except for COLOR
    • Example of multicolor formatting <td style="color:lightgray;">'''White'''<span style="color:green">'''Green'''</span></td>
      • user the same color name for "color", except use "color:lightgray" for white
PIN COLOR NAME DESCRIPTION
1 Red VCC Power supply (+8-32V V DC) (+)
2 Gray DOUT3 Digital output channel 3
3 White DIN3/AIN3 Digital input channel 3 / Analog input channel 3
4 WhiteGreen DIN4/AIN4/DGS Digital input channel 4 / Analog input channel 4 / Ground sense
5 Yellow DIN1/AIN1 Digital input 1 / Analog input 1
6 WhiteBlue INPUT6 TX EXT (LVCAN – TX)
7 Black GND Ground (-)
8 WhiteOrange DOUT1 Digital output channel 1
9 Purple DOUT2 Digital output channel 2
10 Blue 1WIRE POWER +3.8 V output for 1-Wire devices
11 Green DIN2/AIN2/1WIRE DATA Digital input channel 2 / Analog input 2 / Data for 1-Wire devices
12 WhiteYellow INPUT5 RX EXT (LVCAN – RX)

PCN

Rules:

  • Avoid inline formatting
ITEM iNFORMATION
Change details
Change type Firmware update
Description Key improvements from last production firmware are listed in errata: [[{{{model}}} Firmware Changelog]]
Previous firmware version 0.26.2
New firmware version 2.1.1
Change reason {{{model}}} base firmware version update
Product release date 2025 June
Affected products
Model {{{model}}}
Affected order codes All order codes
Order code change New firmware version
Impact
Risk assessment During the transition period, clients might receive devices manufactured with the previous firmware version.

LED Behavior

Rules:

  • Avoid inline formatting
  • Do not leave cells empty - write "-" if there is no value
STATUS LED (WHITE) NAVIGATION LED (BLUE)
ONDevice is working, GPRS session not activeGNSS is working, position fix not acquired
BLINK every 1 secondDevice is working, GPRS session active -
SHORT BLINK every 1 second -GNSS is working, position fix acquired
OFFDevice is not workingGNSS is powered off (device not working or in sleep mode)

Electrical Specifications

Rules:

  • Avoid inline formatting
  • Leave cells without any data empty (as opposed to other tables)
SPECIFICATION MIN MAX UNITS
Supply
Supply Voltage 10 97 V
Supply Protection Voltage (Absolute Maximum Ratings, Reverse/Forward Polarity) -100 100 V
Inputs
Analog Input 1 Voltage 0 100 V
Analog Input 1 Current (At 100V Input) 0.7 mA
Digital Input 1 Voltage (DIN state 0->1) 2.5 100 V
Digital Input 1 Current (At 100V Input) 0.7 mA
Outputs
Digital Output 1 Voltage 0 100 V
Digital Output 1 Current 0 500 mA
Digital Output 1 Overcurrent Threshold 800 mA
Digital Output 2 Voltage 0 100 V
Digital Output 2 Current 0 500 mA
Digital Output 2 Overcurrent Threshold 800 mA