FMB640 Parameter list
System parameters
Sleep Mode (ID=102)
Minimum value | Maximum value | Default value | Goes with (depends on) parameters | Value type |
---|---|---|---|---|
0 | 3 | 2 | Sleep timeout (ID=103) | Uint8 |
Sleep timeout (ID=103)
Minimum value | Maximum value | Default value | Goes with (depends on) parameters | Value type |
---|---|---|---|---|
1 | 3000 | 10 | Sleep Mode (ID=102) | Uint8 |
Static Navigation (ID=106)
Minimum value | Maximum value | Default value | Goes with (depends on) parameters | Value type |
---|---|---|---|---|
0 | 1 | 1 | Static Navigation Settings (ID=112) | Uint8 |
Save records to (ID=1003)
Minimum value | Maximum value | Default value | Goes with (depends on) parameters | Value type |
---|---|---|---|---|
0 | 1 | 0 | Uint8 |
Analog input value range (ID=111)
Minimum value | Maximum value | Default value | Goes with (depends on) parameters | Value type |
---|---|---|---|---|
0 | 1 | 1 | Uint8 |
Analog Input Value Range 3-4 (ID=114)
Minimum value | Maximum value | Default value | Goes with (depends on) parameters | Value type |
---|---|---|---|---|
0 | 1 | 1 | Uint8 |
AIN4/DOUT4 Mode (ID=115)
Minimum value | Maximum value | Default value | Goes with (depends on) parameters | Value type |
---|---|---|---|---|
0 | 1 | 0 | Uint8 |
J1708 settings (ID=116)
Minimum value | Maximum value | Default value | Goes with (depends on) parameters | Value type |
---|---|---|---|---|
0 | 1 | 0 | Uint8 |
Speed Source settings (ID=118)
Minimum value | Maximum value | Default value | Goes with (depends on) parameters | Value type |
---|---|---|---|---|
0 | 4 | 0 | Uint8 |
Saving/Sending without (TS) time synchronization (ID=107)
Minimum value | Maximum value | Default value | Goes with (depends on) parameters | Value type |
---|---|---|---|---|
0 | 1 | 1 | Uint8 |
Ping mode (ID=1004)
Minimum value | Maximum value | Default value | Goes with (depends on) parameters | Value type |
---|---|---|---|---|
0 | 2 | 0 | Uint8 |
Ping timeout (min.)
Minimum value | Maximum value | Default value | Goes with (depends on) parameters | Value type |
---|---|---|---|---|
0 | 259200 | 60 | Uint8 |
GNSS Source (ID=109)
1 – GPS only 2 – GLONASS only 3 – GPS + GLONASS
Minimum value | Maximum value | Default value | Goes with (depends on) parameters | Value type |
---|---|---|---|---|
1 | 3 | 3 | Uint8 |
Ignition settings (ID=101)
Minimum value | Maximum value | Default value | Goes with (depends on) parameters | Value type |
---|---|---|---|---|
1 | 63 | 32 | High voltage level (ID=104) | |
Low voltage level (ID=105) | ||||
Movement Start Delay(s) (ID=19001) | ||||
Movement Stop Delay(s) (ID=19002) | Uint8 |
High voltage level (ID=104)
Minimum value | Maximum value | Default value | Goes with (depends on) parameters | Value type |
---|---|---|---|---|
0 | ||||
(but higher than low level) | 30000 | 30000 | Ignition settings (ID=101) | |
Low voltage level (ID=105) | ||||
Uint16 | ||||
Low voltage level (ID=105)
Minimum value | Maximum value | Default value | Goes with (depends on) parameters | Value type |
---|---|---|---|---|
0 | 29999 (but lower than high level) | 13200 | Ignition settings (ID=101) | |
High voltage level (ID=104) | ||||
Uint16 |
Movement Start Delay(s) (ID=19001)
Minimum value | Maximum value | Default value | Goes with (depends on) parameters | Value type |
---|---|---|---|---|
1 | 60 | 1 | Ignition settings (ID=101) | |
Movement Stop Delay(s) (ID=19002) | Uint8 |
Movement Stop Delay(s) (ID=19002)
Minimum value | Maximum value | Default value | Goes with (depends on) parameters | Value type |
---|---|---|---|---|
5 | 60 | 60 | Ignition settings (ID=101) | |
Movement Start Delay(s) (ID=19001) | Uint16 |
Synchronization settings (ID=900) Settings used for device internal time synchronization: 0 – GPS only, 1 – NITZ and NTP, 2 – NTP, 3 – NITZ.
Minimum value | Maximum value | Default value | Goes with (depends on) parameters | Value type |
---|---|---|---|---|
0 | 3 | 1 | NTP Resync (ID=901) | |
NTP server 1 (ID=902) | ||||
NTP server 2 (ID=903) | Uint8 |
NTP Resync (ID=901)
Minimum value | Maximum value | Default value | Goes with (depends on) parameters | Value type |
---|---|---|---|---|
0 | 24 | 0 | Synchronization settings (ID=900) | |
NTP server 1 (ID=902) | ||||
NTP server 2 (ID=903) | Uint8 |
NTP server 1 (ID=902)
Minimum value | Maximum value | Default value | Goes with (depends on) parameters | Value type |
---|---|---|---|---|
0 | 55 char string | avl1.teltonika.lt | Synchronization settings (ID=900) | |
NTP Resync (ID=901) | ||||
NTP server 2 (ID=903) | S8[55] |
NTP server 2 (ID=903)
Minimum value | Maximum value | Default value | Goes with (depends on) parameters | Value type |
---|---|---|---|---|
0 | 55 char string | pool.ntp.org | Synchronization settings (ID=900) | |
NTP Resync (ID=901) | ||||
NTP server 1 (ID=902) | S8[55] |