FMB640 Parameter list

From Wiki Knowledge Base | Teltonika GPS
Main Page > EOL Products > FMB640 > FMB640 Manual > FMB640 Parameter list


System parameters

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
102 Uint8 2 0 3 0 – Disabled Movement source
1 – GPS Sleep
2 – Deep Sleep
3 – Online Deep Sleep
103 Uint8 10 1 3000 Minutes Sleep timeout
106 Uint8 1 0 1 Boolean Static Navigation
1003 Uint8 0 0 1 Boolean Save records to
111 Uint8 1 0 1 Boolean Analog input value range
114 Uint8 1 0 1 Boolean Analog Input Value Range 3-4
115 Uint8 0 0 1 Boolean AIN4/DOUT4
116 Uint8 0 0 1 Boolean J1708 settings
117 Uint8 0 0 4 Mode Odometer Source Settings
118 Uint8 0 0 4 Mode Speed Source settings
107 Uint8 1 0 1 Boolean Saving/Sending without (TS) time synchronization
1004 Uint8 0 0 2 Mode Ping mode
1005 Uint8 60 0 259200 Minutes Ping timeout (min.)
109 Uint8 3 1 3 0 - Disable GNSS Source
1 - GPS only
2 - GLONASS only
3 - GPS + GLONASS
101 Uint8 32 1 63 Mode Ignition settings
104 Uint16 30000 0 30000 Millivolts Sets High voltage level
105 Uint16 13200 0 29999 Millivolts Low voltage level
19001 Uint8 1 1 60 Seconds Movement Start Delay(s)
19002 Uint16 60 5 60 Seconds Movement Stop Delay(s)
900 Uint8 1 0 3 GPS only Synchronization settings
1 – NITZ and NTP
2 – NTP
3 – NITZ
901 Uint8 0 0 24 Hours NTP Resync
902 S8[55] avl1.teltonika.lt 0 55 char string Char string NTP server 1
903 S8[55] pool.ntp.org 0 55 char string Server address NTP server 2


GPRS parameters

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1002 Uint8 0 0 1 Boolean Sorting
1000 Uint32 30 259200 30 Seconds Open Link Timeout
1001 Uint16 30 5 300 Seconds Server Response Timeout
2000 Uint8 1 0 1 Boolean SIM1 GPRS content activation
2001 S8[32] Empty 0 32 char string Text SIM1 APN Name
2002 S8[30] Empty 0 30 char string Text SIM1 APN username
2003 S8[30] Empty 0 30 char string Text SIM1 APN Password
2011 Uint8 1 0 1 Boolean SIM2 GPRS content activation
2012 S8[32] Empty 0 32 char string Text SIM2 APN Name
2013 S8[30] Empty 0 30 char string Text SIM2 APN username
2014 S8[30] Empty 0 30 char string Text SIM2 APN Password
2004 S8[55] Empty 0 55 char string Internet address Server #1 Domain
2005 Uint16 0 0 65535 Port number Target Server #1 Port
2006 Uint8 0 0 1 Boolean Server #1 Protocol
2007 S8[55] Empty 0 55 char string Internet address Server #2 Server Domain
2008 Uint8 0 0 65535 Port number Server #2 Server Port
2009 Uint8 0 0 1 Boolean 2nd Server Protocol
13003 Uint8 1 0 1 Boolean FOTA WEB status
13000 S8[55] 85.206.140.106 0 55 char string Internet address FOTA WEB Domain
13001 Uint8 5000 0 65535 Port number FOTA WEB port
13002 Uint16 720 30 65535 Minutes FOTA WEB Period (min)


SMS/Call settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
3000 Uint8 0 0 1 Boolean SMS data sending settings
1002 S8[16] Empty Empty 16 digits Phone number Data send number
4000-4199 S8[16] Empty Empty 16 digits Phone number(s) Authorized phone numbers
9000-9009 Uint8 0 0 255 AVL ID(s) SMS Events AVL ID list
7000-7009 S8[16] Empty Empty 16 digits GSM Number(s) GSM Predefined Numbers [1-10]
3004 S8[5] Empty Empty 5 char Text SMS Password
3005 Uint8 0 0 4 Mode Incoming call action
3006 Uint16 0 -720 840 Number SMS Event Time Zone
3009 Uint8 0 0 10 Phone number DIN 1 GSM Number
3011 Uint8 0 0 1 Boolean DIN 2 Call Trigger
3012 Uint8 0 0 10 Phone number DIN 2 GSM Number
3013 Uint8 0 0 1 Boolean DIN 3 Call Trigger
3014 Uint8 0 0 10 Phone number DIN 3 GSM Number
3015 Uint8 0 0 1 Boolean DIN 4 Call Trigger
3016 Uint8 0 0 10 Phone number DIN 4 GSM Number


GSM Operators

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
5000-5049 Uint32 0 0 999999 MCC+MNC number(s) SIM1 Roaming Operator List
9500-9549 Uint32 0 0 999999 MCC+MNC number(s) SIM2 Roaming/ Home Operator List
5500-5549 Uint32 0 0 999999 MCC+MNC number(s) Black List


Data Acquisition

  • Home Network GSM operator code “Vehicle on STOP” parameters
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
10000 Uint32 3600 0 2592000 Seconds Min Period
10005 Uint32 120 0 2592000 Seconds Send Period
10004 Uint8 1 1 255 Amount Min Saved Records
  • Home Network GSM operator code “Vehicle MOVING” parameters
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
10050 Uint32 3600 0 2592000 Seconds Min Period
10051 Uint16 100 0 65535 Amount Min Distance
10053 Uint8 10 0 180 Number Min Angle
10053 Uint32 10 0 255 Seconds Min Speed Delta
10055 Uint32 120 0 2592000 Seconds Send Period
10054 Uint8 1 1 255 Amount Min Saved Records
  • Roaming Network GSM operator code “Vehicle on STOP” parameters
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
10100 Uint32 3600 0 2592000 Seconds Min Period
10105 Uint32 120 0 2592000 Seconds Send Period
10104 Uint8 1 1 255 Amount Min Saved Records
  • Roaming Network GSM operator code “Vehicle MOVING” parameters
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
10150 Uint32 300 0 2592000 Seconds Min Period
10151 Uint16 100 0 65535 Amount Min Distance
10152 Uint8 10 0 180 Number Min Angle
10153 Uint32 10 0 255 Seconds Min Speed Delta
10155 Uint32 120 0 2592000 Seconds Send Period
10154 Uint8 1 1 255 Amount Min Saved Records
  • Unknown Network GSM operator code “Vehicle on STOP” parameters
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
10200 Uint32 3600 0 2592000 Seconds Min Period
10205 Uint32 120 0 2592000 Seconds Send Period
10204 Uint8 1 1 255 Amount Min Saved Records
  • Unknown Network GSM operator code “Vehicle MOVING” parameters
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
10250 Uint32 300 0 2592000 Seconds Min Period
10251 Uint16 100 0 65535 Amount Min Distance
10252 Uint8 10 0 180 Number Min Angle
10253 Uint32 10 0 255 Seconds Min Speed Delta
10255 Uint32 120 0 2592000 Seconds Send Period
10254 Uint8 1 1 255 Amount Min Saved Records

Features

  • Green driving parameters
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11004 Uint8 25 25 85 mG Max acceleration
11005 Uint8 35 25 85 mG Max braking
11006 Uint8 30 10 100 mG Max cornering
11007 Uint8 0 0 1 0 – GPS Source
1 – Accelerometer
11003 Uint8 0 0 5 0 – None Green driving digital output control settings
1 – No DOUT control
2 – DOUT 1
3 – DOUT 2
4 – DOUT 3
5 – DOUT 4
11009 float 0.1 0.1 10 Milliseconds Acceleration Digital output on duration
11010 float 0.1 0.1 10 Milliseconds Braking Digital output on duration
11011 float 0.1 0.1 10 Milliseconds Cornering Digital output on duration
  • Overspeeding parameters
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11103 Uint8 0 0 5 0 – Disable Overspeeding output control
1 – No DOUT control
2 – DOUT1
3 – DOUT2
4 – DOUT3
5 – DOUT4
11104 Uint16 90 0 260 Speed Max allowed Speed
  • Jamming parameters
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11304 Uint8 0 0 5 0 – Disable Overspeeding output control
1 – No DOUT control
2 – DOUT1
3 – DOUT2
4 – DOUT3
5 – DOUT4
11303 Uint8 1 0 1 Boolean Jamming Eventual records
11305 Uint16 60 0 65535 Seconds Time Until Jamming Event Detection
11305 Uint16 60 0 65535 Seconds Time Until Jamming Event Detection
11301 Int32 60 0 65530 Milliseconds Jamming DOUT on duration [ms]
11306 Uint8 0 0 2 Mode Jamming Sensitivity Control
  • Immobilizer parameters
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11702 Uint8 0 0 5 0 – Disable Immobilizer output control
1 – No DOUT control
2 – DOUT1
3 – DOUT2
4 – DOUT3
5 – DOUT4
11701 Uint8 1 0 1 Boolean Eventual records
11703 Uint8 0 0 1 Boolean iButton list check
  • iButton read notification parameters
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11704 Uint8 0 0 5 0 – Disable iButton read notification output control
1 – No DOUT control
2 – DOUT1
3 – DOUT2
4 – DOUT3
5 – DOUT4
11705 Uint8 200 100 5000 Milliseconds Duration timeout [ms]