| Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
|---|---|---|---|---|---|---|
| Min | Max | |||||
| 2000 | S8 | 1 | 0 | 3 | 0 – Disabled | I/O#1 Priority |
| 1 – Low | ||||||
| 2 – High | ||||||
| 3 – Panic | ||||||
| 2001 | S32 | 0 | -2147483647 | 2147483647 | I/O#1 High level | |
| 2002 | S32 | 0 | -2147483647 | 2147483647 | I/O#1 Low level | |
| 2003 | S8 | 3 | 0 | 5 | 0 – On Exit | I/O#1 event generation type |
| 1 – On Entrance | ||||||
| 2 – On Both | ||||||
| 3 – Monitoring | ||||||
| 4 – Hysteresis | ||||||
| 5 – On Change | ||||||
| 2004 | S32 | 10 | 0 | 2592000 | I/O#1 averaging length | |
Other I/O property elements can be configured in same logic. All I/O element parameters are listed in the next table.
| I/O Element Number | I/O element parameters |
|---|---|
| Digital Input 1 | 2000-2004 |
| Digital Input 2 | 2010-2014 |
| Digital Input 3 | 2020-2024 |
| Digital Input 4 | 2030-2034 |
| Analog Input 1 | 2040-2044 |
| Digital Output 1 | 2050-2054 |
| Digital Output 2 | 2060-2064 |
| GNSS PDOP | 2070-2074 |
| GNSS HDOP | 2080-2084 |
| External Voltage | 2090-2094 |
| GNSS Power | 2100-2104 |
| Movement Sensor | 2110-2114 |
| Odometer Value | 2120-2124 |
| GSM Operator | 2130-2134 |
| Speed | 2140-2144 |
| iButton ID | 2150-2154 |
| Data Mode | 2160-2164 |
| GSM Signal | 2170-2174 |
| Deep Sleep | 2180-2184 |
| Cell ID | 2190-2194 |
| Area Code | 2200-2204 |
| Dallas Temperature 1 | 2210-2214 |
| Dallas Temperature 2 | 2220-2224 |
| Dallas Temperature 3 | 2230-2234 |
| Battery Voltage | 2240-2244 |
| Battery Current | 2250-2254 |
| Ignition | 2260-2264 |
| Network Type | 2270-2274 |
| Continuous odometer | 2280-2284 |
| Dallas Temperature ID 1 | 2290-2294 |
| Dallas Temperature ID 2 | 2300-2304 |
| Dallas Temperature ID 3 | 2310-2314 |