From Teltonika Telematics Wiki
Green Drivind scenario
| Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
| Min
|
Max
|
| ID
|
U8
|
default
|
min
|
max
|
0 – value = 0
|
Name
|
| 1 – value = 1
|
| ID
|
U8
|
default
|
min
|
max
|
Value
|
Name
|
| 1600
|
U8
|
0
|
0
|
3
|
0 – disable
|
Green Driving scenario
|
| 1 – Dout not control scenario
|
| 2 – Dout1 controls scenario
|
| 3 – Dout2 controls scenario
|
| 1602
|
Float
|
0.25
|
0.25
|
0.85
|
G
|
Max Acceleration Force
|
| 1603
|
Float
|
0.25
|
0.35
|
0.85
|
G
|
Max Braking Force
|
| 1604
|
U16
|
0.3
|
0.1
|
1.0
|
rad/second
|
Max Cornering Force
|
Over Speeding
| Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
| Min
|
Max
|
| 1601
|
U8
|
0
|
0
|
3
|
0 – disable
|
OverSpeeding scenario
|
| 1 – Dout not control scenario
|
| 2 – Dout1 controls scenario
|
| 3 – Dout2 controls scenario
|
| 1605
|
U16
|
0
|
0
|
260
|
km/h
|
Max Cornering Force
|
Jamming
| Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
| Min
|
Max
|
| 1606
|
U8
|
0
|
0
|
3
|
0 – disable
|
Jamming detection scenario
|
| 1 – Dout not control scenario
|
| 2 – Dout1 controls scenario
|
| 3 – Dout2 controls scenario
|
Immobilizer
| Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
| Min
|
Max
|
| 1607
|
U8
|
0
|
0
|
3
|
0 – disable
|
Immobilizer scenario
|
| 1 – Dout not control scenario
|
| 2 – Dout1 controls scenario
|
| 3 – Dout2 controls scenario
|
| 1609
|
U8
|
30
|
5
|
65535
|
seconds
|
Immobilizer ignition timeout
|
| 1608
|
U8
|
0
|
0
|
1
|
0 – disable
|
iButton list checking scenario
|
| 1 – enabled
|
Excessive Idling detection
| Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
| Min
|
Max
|
| 1610
|
U8
|
0
|
0
|
1
|
0 – disable
|
Excessive Idling detection
|
| 1 – enable
|
| 1611
|
U8
|
0
|
0
|
255
|
seconds
|
Time to stationary
|
| 1612
|
U8
|
0
|
0
|
255
|
seconds
|
Time to movement
|
Trip
| Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
| Min
|
Max
|
| 1280
|
U8
|
0
|
0
|
1
|
0 – disable
|
Trip start/stop detection
|
| 1 – enable
|
| 1281
|
U8
|
5
|
0
|
255
|
km/h
|
Start Speed
|
| 1282
|
U16
|
60
|
0
|
65535
|
seconds
|
Ignition Off Timeout
|
| 1283
|
U8
|
0
|
0
|
2
|
0 – Between records
|
Trip distance mode
|
| 1 – Continuous trip
|
| 1 – Continuous
|
| 1284
|
Uint8
|
-
|
0
|
1
|
0 – disable
|
Enable odometer value setting
|
| 1 – enable
|
| 1285
|
U32
|
1
|
0
|
4294967295
|
meters
|
Continuous odometer value
|
| 1286
|
U8
|
0
|
0
|
1
|
0 – disable
|
Name
|
| 1 – enable
|