Template:FM36 Features Parameters

From Wiki Knowledge Base | Teltonika GPS

Green Drivind scenario

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
ID U8 default min max 0 – value = 0 Name
1 – value = 1
ID U8 default min max Value Name
1600 U8 0 0 3 0 – disable Green Driving scenario
1 – Dout not control scenario
2 – Dout1 controls scenario
3 – Dout2 controls scenario
1602 Float 0.25 0.25 0.85 G Max Acceleration Force
1603 Float 0.25 0.35 0.85 G Max Braking Force
1604 U16 0.3 0.1 1.0 rad/second Max Cornering Force

Over Speeding

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1601 U8 0 0 3 0 – disable OverSpeeding scenario
1 – Dout not control scenario
2 – Dout1 controls scenario
3 – Dout2 controls scenario
1605 U16 0 0 260 km/h Max Cornering Force

Jamming

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1606 U8 0 0 3 0 – disable Jamming detection scenario
1 – Dout not control scenario
2 – Dout1 controls scenario
3 – Dout2 controls scenario

Immobilizer

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1607 U8 0 0 3 0 – disable Immobilizer scenario
1 – Dout not control scenario
2 – Dout1 controls scenario
3 – Dout2 controls scenario
1609 U8 30 5 65535 seconds Immobilizer ignition timeout
1608 U8 0 0 1 0 – disable iButton list checking scenario
1 – enabled

Excessive Idling detection

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1610 U8 0 0 1 0 – disable Excessive Idling detection
1 – enable
1611 U8 0 0 255 seconds Time to stationary
1612 U8 0 0 255 seconds Time to movement

Trip

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1280 U8 0 0 1 0 – disable Trip start/stop detection
1 – enable
1281 U8 5 0 255 km/h Start Speed
1282 U16 60 0 65535 seconds Ignition Off Timeout
1283 U8 0 0 2 0 – Between records Trip distance mode
1 – Continuous trip
1 – Continuous
1284 Uint8 - 0 1 0 – disable Enable odometer value setting
1 – enable
1285 U32 1 0 4294967295 meters Continuous odometer value
1286 U8 0 0 1 0 – disable Name
1 – enable

Geofencing

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1020 U32 1000 0 1000000 meters Frame border
Geofence Zone #1 parameters
1030 U8 0 0 1 0 – circle Geofence Zone #1 Shape
1 – rectangle
1031 U8 0 0 3 0 – disabled Geofence Zone #1 Priority
1 – low
2 – high
3 – panic
1032 U8 0 0 2 0 – On exiting zone Geofence Zone #1 Generate Event
1 – On entering zone
2 – On both
1033 Float - -180 180 number Geofence Zone #1 Longitude (X1)
1034 Float - -90 90 number Geofence Zone #1 Latitude (Y1)
if parameter Geofence Zone #1 Shape (1030) - rectangle
1035 Float 0 -180 180 number Geofence Zone #1 Longitude (X2)
1036 Float 0 -90 90 number Geofence Zone #1 Latitude (Y2)
if parameter Geofence Zone #1 Shape (1030) - circle
1035 Float 0 0 1000000 meter Geofence Zone #1 radius
1036 If shape is circle, parameter ID = 1036 is not used.