Revision as of 10:10, 23 August 2018 by Marek.rakalovic(talk | contribs)(Created page with "{{Template:FMB General description|model=FMA110}} {{FMA120 Package contents|model=FMA110}} ==Basic characteristics== {{FMA Basic characteristics}} {{FMA GNSS Features}}...")
FMA110 is a tracking terminal with GNSS and GSM connectivity, which is able to collect device coordinates and transfer them via GSM network to a server. This device is perfectly suitable for applications, which require the location acquirement of remote objects.
Package contents
The FMA110 device is supplied to the customer in a cardboard box containing all the equipment that is necessary for operation. The package contains:
FMA110 device;
Input and output power supply cable with 2x5 connection pins;
GPRS: average 120 mA rms Nominal: average 65 mA rms GNSS sleep: average 28 mA Deep Sleep: average 5 mA²
Battery charge current
Average 115 mA
Operating temperature (without battery)
-40°C..+85 °C
Operating temperature (without battery)
-40°C..+85 °C
Storage relative humidity
5..95% (no condensation)
Internal fuse
3A, 125V
Dimension drawing:
Technical information about internal battery
Internal back-up battery
Battery voltage (V)
Nominal Capacity (mAh)
Power (Wh)
Charge temperature (°C)
Discharge temperature (°C)
Storage temperature (°C)
Li-ion rechargeable battery
3.75~3.90
170
0.64 – 0.66
0 to +45
-20 to +60
-20 to +45 for 1 month -20 to +35 for 6 months
Batteries are covered by 6 month warranty support.
CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.
Battery should not be disposed of into general household waste. Bring damaged or worn-out batteries to your local recycling center or dispose them into a battery recycle bin commonly found in supermarkets.
Electrical characteristics
Characteristic description
Value
Min.
Typ.
Max.
Unit
Supply Voltage:
Supply Voltage (Recommended Operating Conditions)
5
30
V
Digital Input:
Input resistance (DIN1)
120
kOhm
Input resistance (DIN2, DIN3)
15
kOhm
Input Voltage (Recommended Operating Conditions)
0
Supply voltage
V
Input Voltage threshold (DIN1)
7.5
V
Input Voltage threshold (DIN2, DIN3)
2.6
V
Digital Output (Open Drain grade):
Drain Current (Digital Output OFF)
120
uA
Drain Current (Digital Output ON, Recommended Operating Conditions)
Input voltage (Recommended Operating Conditions), Range 1
0
10
V
Input resistance, Range 1
120
kOhm
Measurement error
4.4
%
Additional error
±26
mV
Input Voltage (Recommended Operating Conditions) Range2
0
30
V
Input resistance, Range2
146.7
kOhm
Measurement error
4
%
Additional error
±40
mV
Output Supply Voltage 1-Wire:³
Supply voltage
3.3
3.6
V
Output inner resistance
10
Ohm
Output current (Uout > 3.0 V)
30
mA
Short circuit current (Uout = 0)
130
mA
Analog Input error margin can increase if temperature varies. If Analog input is not connected FMA110 will still measure certain numbers and it cannot be 0. This measurement is influenced by hardware components.
Absolute Maximum Ratings
Characteristic description
Value
Min.
Typ.
Max.
Unit
Supply Voltage (Absolute Maximum Ratings)
-32
32
V
Drain-Source clamp threshold voltage (Absolute Maximum Ratings), (Idrain = 2mA)