Template:FMA110 Electrical characteristics
From Wiki Knowledge Base | Teltonika GPS
Revision as of 10:41, 23 August 2018 by Marek.rakalovic (talk | contribs) (Created page with "==Electrical characteristics== {| class="wikitable" |+ ! style="width: 400px; background: black; color: white;" rowspan=2 | Characteristic description ! style="width: 300px;...")
Electrical characteristics
Characteristic description | Value | |||
---|---|---|---|---|
Min. | Typ. | Max. | Unit | |
Supply Voltage: | ||||
Supply Voltage (Recommended Operating Conditions) | 5 | 30 | V | |
Digital Input: | ||||
Input resistance (DIN1) | 120 | kOhm | ||
Input resistance (DIN2, DIN3) | 15 | kOhm | ||
Input Voltage (Recommended Operating Conditions) | 0 | Supply voltage | V | |
Input Voltage threshold (DIN1) | 7.5 | V | ||
Input Voltage threshold (DIN2, DIN3) | 2.6 | V | ||
Digital Output (Open Drain grade): | ||||
Drain Current (Digital Output OFF) | 120 | uA | ||
Drain Current (Digital Output ON, Recommended Operating Conditions) | 300 | mA | ||
Static Drain-Source Resistance (Digital Output ON) | 300 | mOhm | ||
Analog Input: | ||||
Input voltage (Recommended Operating Conditions), Range 1 | 0 | 10 | V | |
Input resistance, Range 1 | 120 | kOhm | ||
Measurement error | 4.4 | % | ||
Additional error | ±26 | mV | ||
Input Voltage (Recommended Operating Conditions) Range2 | 0 | 30 | V | |
Input resistance, Range2 | 146.7 | kOhm | ||
Measurement error | 4 | % | ||
Additional error | ±40 | mV | ||
Output Supply Voltage 1-Wire:³ | ||||
Supply voltage | 3.3 | 3.6 | V | |
Output inner resistance | 10 | Ohm | ||
Output current (Uout > 3.0 V) | 30 | mA | ||
Short circuit current (Uout = 0) | 130 | mA |