FMP100 Sleep modes

From Wiki Knowledge Base | Teltonika GPS
Revision as of 09:11, 20 April 2020 by Kaminskas.Andrius (talk | contribs) (Protected "FMP100 Sleep modes" ([Edit=Allow only administrators] (indefinite) [Move=Allow only administrators] (indefinite)))

Main Page > Fast & Easy Trackers > FMP100 > FMP100 Manual > FMP100 Sleep modes

There are four sleep modes: GPS sleep, Deep sleep, Online Deep sleep, and Ultra Deep-sleep mode.

Video Demonstration

Here is a visual demonstration of the sleep modes and how they they affect the device.


GPS Sleep mode

FMP100 is able to go into GPS sleep mode if such mode is enabled.
Sleep mode timeout starts counting when the device is in STOP mode. After timeout is reached and all conditions for GPS sleep mode are met, the device goes into sleep mode.

GPS Sleep .gif

When in GPS sleep mode, FMP100 turns the GPS module off and continues making new periodic records. As a result power usage decreases, in turn saving vehicle battery.
FMP100 will enter GPS sleep mode if ALL of these conditions are met:
  • FMP100 is configured to work in GPS Sleep mode and sleep timeout is reached;
  • Device time must be synchronized with GPS satellites. From Firmware 03.18.15 version, this condition depends on the “Records saving/sending without TS” parameter:
  • After Position Fix - FMP100 time is synchronized with GNSS satellites and GPS fix is obtained;
  • After Time Sync - FMP100 time is synchronized over NTP, NITZ, or GNSS satellites;
  • Always - FMP100 will enter sleep mode without time synchronization and GPS fix.
  • Movement is not detected by the accelerometer and configured movement source;
  • Ignition (configured ignition source) is off;
  • There are no SMS messages being received.
Bw nb.png On Firmware version older than 03.18.15, the device time has to be synchronized with GNSS satellites and GPS fix has to be obtained in order for the device to enter GPS Sleep mode.


FMP100 exits GPS sleep mode if ONE of following conditions is true:

  • Movement by accelerometer or configured movement source is detected;
  • Ignition (configured ignition source) is turned on.

Deep Sleep mode

While in deep sleep mode, FMP100 sets the GNSS receiver to sleep mode and turns off GSM/GPRS module (hence it is not possible to wake up the device via SMS). Despite records with the last known coordinate being saved and sent to the AVL server (GSM/GPRS module is turned on to send data and then it is turned off), power usage is decreased to save the vehicle's battery.

Deep Sleep .gif

Please note that power saving depends on two configurable parameters: Send Period and Minimum Record Saving Period in "X on Stop Mode". When records are sent successfully in deep sleep mode, open link timeout counter will be skipped and FMP100 will enter deep sleep mode immediately.
Because a lot of functions are disabled in deep sleep mode following I/O elements are disabled from records that are generated in this mode: GSM Signal, GNSS Status, GNSS PDOP, GNSS HDOP, GSM CellID, GSM Area Code, Active GSM Operator, Trip Odometer, Total Odometer, Speed, Fuel Rate GPS, Fuel Used GPS and ICCID.


FMP100 can enter deep sleep mode if ALL of these conditions are met:

  • FMP100 is configured in Deep Sleep mode and sleep timeout is reached;
  • Device time must be synchronized with GPS satellites. From Firmware 03.18.15 version, this condition depends on the “Records saving/sending without TS” parameter:
  • After Position Fix - FMP100 time is synchronized with GNSS satellites and GPS fix is obtained;
  • After Time Sync - FMP100 time is synchronized over NTP, NITZ, or GNSS satellites;
  • Always - FMP100 will enter sleep mode without time synchronization and GPS fix.
  • Ignition (configured ignition source) is off;
  • Movement is not detected by the accelerometer or configured movement source;
  • Min. Record Saving Period (Data Acquisition Mode settings) must be larger than Open Link Timeout parameter, so that FMP100 could close GPRS link;
  • The difference between Send Period (Data Acquisition Mode settings) and Open Link Timeout must be more than 90 seconds, so that FMP100 could close GPRS link within at least 90 seconds;
  • There are no SMS messages being received;
  • Data socket(s) are closed;
  • Data sending is not in progress;
  • FOTA is not in progress.
Bw nb.png On Firmware version older than 03.18.15, the device time has to be synchronized with GNSS satellites and GPS fix has to be obtained in order for the device to enter Deep Sleep mode.


FMP100 exits deep sleep mode if ONE of following conditions is true:

  • Movement by accelerometer or configured movement source is detected;
  • Ignition (configured ignition source) is turned on.

Online Deep Sleep mode

In this mode, the device works as in deep sleep mode, but without deregistering from the GSM network. GSM part stays powered so this increases power consumption. In this mode, the device should send/receive SMS and make/accept calls. It does not close the GPRS context if one was previously opened.


Online Deep Sleep .gif

Conditions to enter online deep sleep mode are the same as entering deep sleep mode. FMP100 exits online sleep mode if ONE of following conditions is true:

  • Movement by accelerometer or configured movement source is detected;
  • Ignition (configured ignition source) is turned on.



Ultra Deep Sleep mode

Conditions to enter ultra deep sleep mode, where GPS and GSM modem are turned off and device functions are suspended for maximum battery saving, are the same as entering deep sleep mode.
FMP100 exits ultra deep sleep mode only when movement is detected by accelerometer. Movement source and Ignition source configuration is not taken into account in this case.

Ultra Sleep.gif