FLEET MAINTENANCE SCHEDULES (DELIVERY)

From Wiki Knowledge Base | Teltonika GPS
Main Page > General Information > Usage scenarios > FLEET MAINTENANCE SCHEDULES (DELIVERY)

Project description

Delivery service is a business where efficiency is everything. Customers expect their goods to be delivered in time and meeting these expectations is a must if the company wants to make a solid profit. Anything what causes delays should be minimized or eliminated. Facilitated by GPS devices, timely vehicle maintenance can greatly reduce the number of irregularities and, thus, help the business grow.

We glad that you decide to test our “Fleet Maintenance Schedules (Delivery)” solution.

Here you will find how to prepare and to test this solution.

What you need for a solution?

  • Teltonika FM device which is compatible with this use case and have OBD connection and can read OBDII data. Recommended devices: FMB001, FMC001, FMM001, FMB003, FMB002. Also, it is possible to use FMP100 and FMB910 via Bluetooth function but it requires Bluetooth OBDII dongle.
  • The SIM card in order to get data to your server.
  • FOTA to remotely send the configuration to the device.
  • Teltonika Configurator to set up FM device correctly for the solution.

Installation

Connecting the device to the vehicle:

  • Before connecting the device to the OBDII socket, make sure that ≥3A fuse is present on OBD connector power supply.
  • Find OBDII connector in your vehicle ( Figure 1.) if you need more accurate location please visit Location of OBD plug.
Figure 1. Most common OMBDII connector locations

Configuration

1. Prerequisites:

1.1. Read through First start guide

1.2. Understanding of possible Sleep modes.


2. Configuring Fleet Maintenance Schedules:

Trip settings.png

Parameter ID - Parameter name

Trip settings:

  • 11800 - Scenario priority (0 - Disable, 1 - Low, 2 - High, 3 - Panic).


  • 11801 - Eventual settings (0 - Disable, 1 - Enable), if disabled - trip settings will come with periodical data.


  • 11802 - Mode (0 - Continuous, 1 Between Records). If Between Records option is selected distance will be counted until any record is made. Then odometer will be reset to zero and start counting until next record is made. When it is set to Continuous, Trip distance is going to be counted continuously (from Trip start to Trip end) and written to I/O Trip Odometer value field. When Trip is over and the next Trip begins, Trip Odometer value is reset to zero.
  • 11803 - Start Speed (km/h). If start speed selected 0 the trip only will work then ignition is on.
  • 11804 - Ignition OFF timeout (s).
  • 7031 - ID of SMS recipient.
  • 8031 - SMS Text.
  • 700 - Eco Score Allowed Events.
  • 11806 - Odometer Calculation Source (0 - GNSS, 1 - OBD).
  • 11807 - current Odometer Value (km). Odometer data will be counted from provided value.
  • 11806 - Odometer Calculation Source (0 - GNSS, 1 - OBD).
  • 11807 - current Odometer Value (km). Odometer data will be counted from provided value.
Screenshot 2021-03-07 162223.png

Ignition Source:

  • 101 - Eventual settings (1 - DIN 1, 2 - Accelerometer, 4 - Power Voltage, 8 - Engine RPM).
  • 104 - Hight Voltage ( MIN - 0, MAX - 30000).
  • 105 - Low Voltage ( MIN - 0, MAX - 29999).





Quick start: From default configuration to Fleet Maintenance Schedules in one SMS:

"  setparam 11800:1;11801:0;101:4;104:30000;105:12000"

Note: Before SMS text, two space symbols should be inserted if no SMS username or password was set in SMS \ Call settings.

After configuration device start parameters now we go to configure OBD II elements.

In the photo below (this is example case) you see where you must go to configurate main parameter that you need to have from device.

In OBD II window you see lot of I/O elements in this window you will configure device in your needed scenario.

Obd turbo.jpg

Parsing Fleet Maintenance Schedule records

1.Prerequisites:

1.1. Open TCP/UDP port

1.2. Go to Java parser first start guide

2.Parsing example:

Unparsed received data in hexadecimal stream
00000000000004d608130000017738b113a8000efcea74209c63c200b60096050010000c05ef01f0011505c800

450105b50008b600074230fB6c430f3d44006b02f10000601a1000038753000 000017738b1241790000efceb6e

209c63d05b50008b600074230 ff430f3d44006b020000601a100003875300002900017738b11f600001f0011505

AVL Data Packet Part HEX Code Part
Zero Bytes 00 00 00 00
Data Field Length 00 00 04 d6
Codec ID 08 (Codec 8)
Number of Data 1 (Number of Total Records) 13
Timestamp 00 00 01 77 38 b1 13 a8 (Mon Jan 25 08:37:46 UTC 2021)
Priority 00
Longitude 00 01 77 38
Latitude b1 13 a8 00
Altitude 0e fc
Angle ea 74
Satellites 20
Speed 9c 63
N of Total ID 12
N1 of One Byte IO 09
1’st IO ID EF (AVL ID: 239, Name: Ignition)
1’st IO Value 01
2’nd IO ID F0 (AVL ID: 240, Name: Movement)
2’nd IO Value 01
3’rd IO ID 15 (AVL ID: 21, Name: GSM Signal)
3’rd IO Value 05
4'th IO ID 50 (AVL ID: 200, Name: Sleep Mode)
4'th IO Value 00
5'th IO ID 45 (AVL ID: 69, Name: GNSS Status)
5'th IO Value 01
N2 of Two Byte IO 5
1’st IO ID B5 (AVL ID: 181, Name: GNSS PDOP)
1’st IO Value 8
2’nd IO ID B6 (AVL ID: 32, Name: Coolant Temperature)
2’nd IO Value 61
3’rd IO ID 42 (AVL ID: 66, Name: External Voltage)
3’rd IO Value 30 FC
4'th IO ID 43 (AVL ID: 67,Name: Battery Voltage)
4'th IO Value 0F 3D
5'th IO ID 24 (AVL ID: 36, Name: Engine RPM)
5'th IO Value 06 A2
N4 of Four Byte IO 02
1'st IO ID 29 (AVL ID: 41, Name: Throttle Position)
1’st IO Value 5E
2’nd IO ID (AVL ID: 16, Name: Total Odometer)
2’nd IO Value 03 87 53
CRC-16 00 00 73 2E

In platform

TAVL: Open TAVL → select client → select Street Map → select device → choose the date from which to which to show the records → push advanced → push show button and then you will see in left down corner all information.

Tavl delivery.jpg

WIALON: Open WIALON → open messages → push unit ( select your device) → choose the date from which to which to show the records → select message (data messages) → push execute button and you will see all information.

Turbo kosmos.jpg