Template:FMB SMS events
SMS events functionality allows FMB1YX to send a configured SMS when an event is triggered. This event can be triggered by every I/O element.
Then any of the I/O elements is triggered, FMB120 sends a configured SMS message to a defined phone number. If SMS events is activated, but there are no numbers defined in GSM PreDefined Numbers list (similarty to ), then the device will not send any messages.
The sent SMS messages format is according to:
“Date Time Current Coordinate Event Text”
For example, if FMB120 is configured to send an SMS, when Ignition reaches High level, with priority High and configured to generate event on both range enter and exit (figure 50), then the sent SMS is:
“2017/06/13 13:52:18 Lon:25.255537 Lat:54.667193 Ignition 1”
The SMS Text field can be altered and any text can be entered. Maximum message length is 160 symbols (numbers, letters and symbols in ASCII, except for comma “,”).