Trip Settings

Fmb120 trip settings.png

Trip window offers user to configure the Trip feature. If Trip is enabled, configuration of Trip parameters is enabled.
Start Speed (km/h) defines the minimum GPS speed in order to detect Trip Start.
Ignition OFF Timeout is the timeout value to detect Trip Stop once the Ignition (configured ignition source) is off.
To use feature Distance counting mode I/O Trip Odometer must be enabled. When it is set to Continuous, Trip distance is going to be counted continuously (from Trip start to Trip stop) and is written to I/O Trip Odometer value field. When Trip is over and next Trip begins, Trip Odometer value is reset to zero.
When Mode is set Between Records, the distance is going to be counted only between every record made. This value is written to I/O Trip Odometer value field and is reset to zero every new record until the Trip stops. If later all Odometer values are summed up manually, the user gets the distance driven during the whole period of the Trip.

Fmb120 trip mode.png

Advanced Trip Settings

Fmb120 advtrip settings.png

Advanced trip settings allow configure number of Eco Score allowed events in 100 km and enable or disable iButton remember functionality.
Eco Score allowed events – how much ECO events is allowed in 100 km. I/O Eco score must be enabled to get value into server. ECO scoring is differentiated by separate Trips.
There are six ECO evaluation events:

  • Harsh acceleration.
  • Harsh braking.
  • Harsh cornering.
  • Over-speeding (count only events with value 1 (start) and ignore value 0(end)).
  • Excessive Idling (count only events with value 1 (start) and ignore value 0(end)).
  • High RPM.

Eco score value can be from 10 (excellent) to 0.00 (very bad):

  • Excellent 8.00 – 10
  • Good 6.00 – 7.99
  • Not Good 4.00 – 5.99
  • Bad 2.00 – 3.99
  • Very Bad 0.00 – 1.99

Score evaluation is calculated like this:
Eco score =10/((Total events)/(Trip distance in km* Allowed events per km)).
Allowed events per km = (Eco Score allowed events/100).

Bw nb.png When Total events < 1, we ignore formula and then Eco score is equal to 10.
If Eco Score allowed events is configured to 0, then Eco score value can have only two values: 0 (when total events > 0) or 10 (when total events = 0).
Bw nb.png Score is updated every 1 km driven or 5 minutes of trip duration.

Remember iButton functionality. If Remember iButton ID while trip detected and Trip parameters are enabled, ignition is on and iButton is attached, then FMB120 remembers iButton ID. iButton ID is saved and sent to server with every record. If new iButton is attached during the trip, FMB120 remembers new iButton ID. FMB120 forgets iButton ID after ignition is off and trip ignition off timeout is reached.

Odometer

Fmb120 odometer.png

Calculation Source allows to choose Odometer calculation source between GNSS, OBD or LVCAN.
Odometer Value sets the starting total odometer value.