From Teltonika Telematics Wiki
System parameters
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
100
|
Uint8
|
0
|
0
|
2
|
0 – Ignition
|
Movement source
|
1 – Movement
|
2 – GPS
|
106
|
Uint8
|
1
|
0
|
1
|
0 – Disable
|
Static navigation
|
1 – Enable
|
107
|
Uint8
|
0
|
0
|
1
|
0 – Disable
|
Send/Save records without TS
|
1 – Enable
|
108
|
Uint8
|
1
|
0
|
1
|
0 – Disable
|
LED Indication
|
1 – Enable
|
109
|
Uint8
|
10
|
1
|
15
|
0 – Undefined
|
GNSS source
|
1 – Beidou only
|
2 – Glonass only
|
3 – Glonass and Beidou not allowed
|
4 – Galileo only
|
5 – Galileo and Beidou
|
6 – Galileo and Glonass
|
7 – Galileo, Glonass and Beidou not allowed
|
8 – Gps only
|
9 – Gps and Beidou
|
10 – Gps and Glonass
|
11 – Gps, Glonass and Beidou not allowed
|
12 – Gps and Galileo
|
13 – Gps, Galileo and Beidou
|
14 – Gps, Galileo and Glonass
|
15 – Gps, Galileo, Glonass and Beidou and not allowed
|
110
|
Uint8
|
0
|
0
|
1
|
0 – On need
|
Battery charge mode|
|
1 – After ignition on
|
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
102
|
Uint8
|
2
|
0
|
2
|
0 – Disable
|
Sleep settings
|
1 – Gps sleep
|
2 – Deep sleep
|
103
|
Uint16
|
1
|
1
|
3000
|
Minutes
|
Timeout
|
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
101
|
Uint8
|
0
|
0
|
2
|
0 – Power voltage
|
Ignition settings
|
1 – Din 1
|
2 – Accelerometer
|
104
|
Uint16
|
30000
|
0
|
30000
|
mV
|
High voltage
|
105
|
Uint16
|
13200
|
0
|
29999
|
mV
|
Low voltage
|
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
900
|
Uint8
|
1
|
0
|
3
|
0 – Gps only
|
Synchronization settings
|
1 – NITZ and NTP
|
2 – NTP
|
3 – NITZ
|
901
|
Uint8
|
0
|
0
|
24
|
Hours
|
NTP Resync
|
902
|
Char
|
"avl1.teltonika.lt"
|
0
|
55
|
String
|
NTP server 1
|
903
|
Char
|
"pool.ntp.org"
|
0
|
55
|
String
|
NTP server 2
|
GPRS parameters
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1000
|
Uint32
|
5
|
0
|
259200
|
Seconds
|
Open link timeout
|
1001
|
Uint16
|
30
|
5
|
300
|
Seconds
|
Response timeout
|
1002
|
Uint8
|
0
|
0
|
1
|
0 – Newest
|
Sort by
|
1 – Oldest
|
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
2000
|
Uint8
|
1
|
0
|
1
|
0 – Disable
|
GPRS context
|
1 – Enable
|
2001
|
Char
|
""
|
0
|
32
|
String
|
APN
|
2002
|
Char
|
""
|
0
|
32
|
String
|
APN username
|
2003
|
Char
|
""
|
0
|
32
|
String
|
APN password
|
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
2004
|
Char
|
""
|
0
|
55
|
String
|
Domain
|
2005
|
Uint16
|
0
|
0
|
65535
|
Number
|
Port
|
2006
|
Uint8
|
1
|
0
|
1
|
0 – TCP
|
Protocol
|
1 – UDP
|
SMS/Call settings
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
3000
|
Uint8
|
0
|
0
|
1
|
0 – Disable
|
Allow SMS data sending
|
1 – Enable
|
3001
|
Char
|
""
|
0
|
16
|
String
|
Data Send Number
|
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
3003
|
Char
|
""
|
0
|
5
|
String
|
Login
|
3004
|
Char
|
""
|
0
|
5
|
String
|
Password
|
3006
|
Uint16
|
UTC+00:00
|
UTC-12:00
|
UTC+13:00
|
Time zone
|
SMS event Time Zone
|
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
3005
|
Uint8
|
0
|
0
|
4
|
0 – Do nothing
|
Incoming call action
|
1 – Hangup
|
2 – Report position
|
3 – Spy call
|
4 – Auto answer
|
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
3007
|
Uint8
|
0
|
0
|
3
|
0 – Disable
|
Outgoing call trigger
|
1 – DIN 1
|
2 – Crash event
|
3 – DIN1 and Crash event
|
3008
|
Uint8
|
0
|
0
|
10
|
GSM number
|
GSM number index
|
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
4000-4009
|
Char
|
""
|
0
|
16
|
String
|
Authorized number
|
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
6000-6009
|
Char
|
""
|
0
|
16
|
String
|
Predefined number
|
GSM operators
Data acquisition mode parameters
Home Network GSM operator code "Vehicle on STOP" parameters
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Parameter name
|
Min
|
Max
|
10000
|
Uint16
|
3600
|
0
|
65535
|
Min Period
|
10004
|
Uint8
|
1
|
1
|
255
|
Min Saved Records
|
10055
|
Uint16
|
120
|
0
|
65535
|
Send Period
|
Home Network GSM operator code "Vehicle MOVING" parameters
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Parameter name
|
Min
|
Max
|
10050
|
Uint16
|
300
|
0
|
65535
|
Min Period
|
10051
|
Uint16
|
100
|
0
|
65535
|
Min Distance
|
10052
|
Uint8
|
10
|
0
|
180
|
Min Angle
|
10053
|
Uint8
|
10
|
0
|
100
|
Min Speed Delta
|
10054
|
Uint8
|
1
|
1
|
255
|
Min Saved Records
|
10055
|
Uint16
|
120
|
0
|
65535
|
Send Period
|
Roaming Network GSM operator code "Vehicle on STOP" parameters
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Parameter name
|
Min
|
Max
|
10100
|
Uint16
|
3600
|
0
|
65535
|
Min Period
|
10104
|
Uint8
|
1
|
1
|
255
|
Min Saved Records
|
10105
|
Uint16
|
0
|
0
|
65535
|
Send Period
|
Roaming Network GSM operator code "Vehicle MOVING" parameters
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Parameter name
|
Min
|
Max
|
10150
|
Uint16
|
300
|
0
|
65535
|
Min Period
|
10151
|
Uint16
|
100
|
0
|
65535
|
Min Distance
|
10152
|
Uint8
|
10
|
0
|
180
|
Min Angle
|
10153
|
Uint8
|
10
|
0
|
100
|
Min Speed Delta
|
10154
|
Uint8
|
1
|
1
|
255
|
Min Saved Records
|
10155
|
Uint16
|
0
|
0
|
65535
|
Send Period
|
Unknown Network GSM operator code "Vehicle on STOP" parameters
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Parameter name
|
Min
|
Max
|
10200
|
Uint16
|
3600
|
0
|
65535
|
Min Period
|
10204
|
Uint8
|
1
|
1
|
255
|
Min Saved Records
|
10205
|
Uint16
|
120
|
0
|
65535
|
Send Period
|
Unknown Network GSM operator code "Vehicle MOVING" parameters
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Parameter name
|
Min
|
Max
|
10250
|
Uint16
|
300
|
0
|
65535
|
Min Period
|
10251
|
Uint16
|
100
|
0
|
65535
|
Min Distance
|
10252
|
Uint8
|
10
|
0
|
180
|
Min Angle
|
10253
|
Uint8
|
10
|
0
|
100
|
Min Speed Delta
|
10254
|
Uint8
|
1
|
1
|
255
|
Min Saved Records
|
10255
|
Uint16
|
0
|
0
|
65535
|
Send Period
|
Features parameters
Green driving parameters
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
11000
|
Uint8
|
0
|
0
|
3
|
0 – Disable
|
Scenario settings
|
1 – Low priority
|
2 – High priority
|
3 – Panic priority
|
11004
|
Uint8
|
25
|
25
|
85
|
mG
|
Max acceleration
|
11005
|
Uint8
|
35
|
25
|
85
|
mG
|
Max braking
|
11006
|
Uint8
|
30
|
10
|
100
|
mG
|
Max cornering
|
11007
|
Uint8
|
0
|
0
|
1
|
0 – GPS
|
Source
|
1 – Accelerometer
|
11008
|
uint8
|
0
|
0
|
1
|
Enable/Disable
|
Duration
|
11003
|
Uint8
|
0
|
0
|
1
|
0 – None
|
Output control
|
1 – DOUT 1
|
11001
|
Int32
|
200
|
0
|
2147483647
|
Milliseconds
|
DOUT ON duration
|
11002
|
Int32
|
200
|
0
|
2147483647
|
Milliseconds
|
DOUT OFF duration
|
7034
|
Uint8
|
0
|
0
|
10
|
Phone number
|
Send SMS to
|
8034
|
String
|
"Green Driving"
|
0
|
160
|
Text
|
Sms text
|
Overspeeding scenario parameters
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
11100
|
Uint8
|
0
|
0
|
3
|
0 – Disable
|
Scenario settings
|
1 – Low priority
|
2 – High priority
|
3 – Panic priority
|
11104
|
Uint16
|
90
|
0
|
260
|
km/h
|
Max speed
|
11103
|
Uint8
|
0
|
0
|
1
|
0 – None
|
Output control
|
1 – DOUT 1
|
11101
|
Int32
|
200
|
0
|
2147483647
|
Milliseconds
|
DOUT ON duration
|
11102
|
Int32
|
200
|
0
|
2147483647
|
Milliseconds
|
DOUT OFF duration
|
7032
|
Uint8
|
0
|
0
|
10
|
Phone number
|
Send SMS to
|
8032
|
String
|
"Overspeeding"
|
0
|
160
|
Text
|
Sms text
|
Jamming scenario parameters
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
11300
|
Uint8
|
0
|
0
|
3
|
0 – Disable
|
Scenario settings
|
1 – Low priority
|
2 – High priority
|
3 – Panic priority
|
11303
|
Uint8
|
1
|
0
|
1
|
0 – Disable
|
Eventual records
|
1 – Enable
|
11304
|
Uint8
|
0
|
0
|
1
|
0 – None |
Output control
|
1 – DOUT 1
|
11301
|
Int32
|
200
|
0
|
2147483647
|
Milliseconds
|
DOUT ON duration
|
11302
|
Int32
|
200
|
0
|
2147483647
|
Milliseconds
|
DOUT OFF duration
|
11305
|
Uint16
|
60
|
0
|
65535
|
Seconds
|
Timeout
|
Immobilizer scenario parameters
Trip scenario parameters
DOUT control via call scenario parameters
iButton read notification
AutoGeofencing scenario parameters
Manual Geofence
First Geozone parameters
Other Geozones
GPS Fuel counter
Accelerometer features
Unplug Detection
Towing Detection
Crash Detection
Excessive Idling
Bluetooth
iButton List
I/O parameters
OBD II (Bluetooth)
LVCAN