Advanced Pulse Counter
From Wiki Knowledge Base | Teltonika GPS
Revision as of 09:17, 9 February 2023 by Rytis.liucvaikis (talk | contribs)
Functionality description
This functionality was added in 03.28.05.Rev.00 firmware version.
If this function is active, then all other settings associated with the this input are disabled.
Frequency measurement can be performed in 2 different ways:
- Frequency is measured by counting pulses over time period (997 ms). Method is used for frequencies higher than 100 Hz.
- Frequency is measured by measuring time between pulses. Method is used for frequencies lower than 100 Hz.
Parameter values
System parameters (ID = 145). Device/Available/Input port/Frequency:
Device | DIN1 | DIN2 | DIN4 | |||
---|---|---|---|---|---|---|
50Hz | 2kHz | 50Hz | 2kHz | 50Hz | 2kHz | |
FMB010/FMB001/FMB002/FMB020/FMB003 | + | |||||
FMB110/FMB120/FMB130/FMB140 | + | + | ||||
FMB202/FMB204/FMB209 | + | + | ||||
FMB920/FMB910 | + | + | ||||
FMC130 | + | + | ||||
FMB207 | + |