Eco/Green Driving

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11000 Uint16 0 0 3 0 – Disable Scenario Settings
1 – Low Priority
2 – High Priority
3 – Panic Priority
11004 Uint8 2,2 0,5 10 m/s² Max acceleration
11005 Uint8 2,5 0,5 10 m/s² Max Braking
11006 Uint8 2,1 0,5 10 rad/s Max Cornering
11007 Uint16 0 0 1 0 – GPS Source
1 – Accelerometer
11008 Uint16 0 0 1 0 – Disable Eco/Green Driving Duration
1 – Enable
11003 Uint16 0 0 2 0 – None Output Control
1 – DOUT1
2 – DOUT2
11001 Uint8 200 100 5000 miliseconds DOUT ON Duration
11002 Uint8 200 0 5000 miliseconds DOUT OFF Duration
7034 Uint16 "" 0 10 Predefined number Send SMS to
8034 String Green Driving 0 160 Char SMS text

Jamming

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11300 Uint8 0 0 3 0 – Disable Scenario Settings
1 – Low Priority
2 – High Priority
3 – Panic Priority
11303 Uint8 1 0 1 0 – Disable Eventual Records
1 – Enable
11305 Uint8 60 0 65535 Seconds Time until Jamming Event Detection

Unauthorized movement

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11720 Uint8 0 0 3 0 – Disable Scenario Settings
1 – Low Priority
2 – High Priority
3 – Panic Priority
11721 Uint8 0 0 1 0 – On Exit UGenerate aven
1 – On Entrance
2 – On Both
11722 Uint8 1 0 30 Seconds Pre-alarm timeout
11723 Uint8 1 0 30 Seconds Time to Stable
11724 Uint8 1 1 5 Seconds Buzzer ON
11725 Uint8 5 2 30 Seconds Buzzer period
7729 Uint16 "" 0 10 Predefined number Send SMS to
8729 String Unauthorized movement 0 160 Char SMS Text

Over speeding

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11100 Uint8 0 0 3 0 – Disable Scenario Settings
1 – Low Priority
2 – High Priority
3 – Panic Priority
11104 Uint32 90 0 6 km/h Max speed
11103 Uint16 0 0 2 0 – None Output Control
1 – DOUT1
2 – DOUT2
11101 Uint8 200 100 5000 miliseconds DOUT ON Duration
11102 Uint8 200 0 5000 miliseconds DOUT OFF Duration
7032 Uint16 "" 0 10 Predefined Number Send SMS to
8032 String Overspeeding 0 160 Char SMS Text

Alarm

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
7245 Uint16 "" 0 10 Predefined Number Send SMS to
8245 String Alarm 0 160 Char SMS Text
11711 Uint8 0 0 1 0 – Call Order priority
1 – Record
11712 Uint16 "" 0 10 Predefined Number Call to

Additional features

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
251 Uint32 0 0 4294967295 number User ID

Power Off/On

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13086 Uint8 "" 0 2 0 – Disable Event On Power Off
1 – Enable
7310 Uint16 "" 0 10 Predefined Number Send SMS to
8310 String Power! Val %val IM %imei 0 160 Char SMS Text

ManDown

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
12100 Uint8 0 0 1 0 – Disable Scenario Settings
1 – Enable
12110 Uint8 1 0 2 0 – On Exit Generate event
1 – On Entrance
2 – On both
12101 Uint8 0 0 1 0 – Horizontal Position
1 – Vertical
12102 Uint32 60 30 150 Degrees Angle
12111 Uint32 5 0 600 Seconds Silent pre-alarm delay
12103 Uint32 3 0 65500 Seconds Pre-alarm timeout
7222 Uint16 "" 0 10 Predefined Number Send SMS to
8222 String ManDown 0 160 Char SMS Text
12104 Uint8 0 0 1 0 – Call Order priority
1 – Record
12105 Uint16 "" 0 10 Predefined Number Call to

Last Known Position

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
51720 Uint8 0 0 1 0 – Disable Scenario Settings
1 – Enable

Unplug Detection

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11500 Uint8 0 0 3 0 – Disable Scenario Settings
1 – Low Priority
2 – High Priority
3 – Panic Priority
11501 Uint8 1 0 1 0 – Disable Eventual Records
1 – Enable
11502 Uint8 0 0 1 0 – Simple Unplug Detection Mode
1 – Advanced
11504 Uint8 0 0 1 0 – Disable Buzzer Control
1 – Enable
11505 Uint8 200 0 65535 Seconds Buzzer ON duration
7036 Uint16 "" 0 10 Predefined number Send SMS to
8036 String Unplug 0 160 Char SMS Text

SIM Card Tamper Protection

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11730 Uint8 0 0 1 0 – Disable Enable/Disable SIM Tamper Protection
1 – Enable
11731 Uint8 0 0 3600 Seconds ICCID

Event Notification

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13053 Uint8 "" 0 7 0 – None Event Notification
1 – Alarm
2 – ManDown
3 – ManDown & Alarm
4 – Movement Event
5 – Movement Event & Alarm
6 – Movement Event & ManDown
7 – Movement Event & ManDown & Alarm
60257 Uint8 0 0 1 0 – GPRS or SMS SMS sending method
1 – GPRS and SMS
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13059 Uint8 "" 0 1 0 – Nobody Call After Answer
1 – Number 2
2 – Number 2 + Number 3
3 – Number 2 + Number 3 + Number 4
4 – Number 2 + Number 3 + Number 4 + Number 5
5 – Number 3
6 – Number 3 + Number 4
7 – Number 3 + Number 4 + Number 5
8 – Number 4
9 – Number 4 + Number 5
10 – Number 5
13055 Uint8 0 0 1 0 – Disable Inform When Answered
1 – Enable
13057 String Answered 0 160 Char SMS Text
13056 Uint8 0 0 1 0 – Disable Inform When Not Answered
1 – Enable
13058 String No answer 0 160 Char SMS Text

SMS Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13060 Uint16 "" 0 10 Predefined Number SMS Number 1
13061 Uint16 "" 0 10 Predefined Number SMS Number 2
13062 Uint16 "" 0 10 Predefined Number SMS Number 3
13063 Uint16 "" 0 10 Predefined Number SMS Number 4
13064 Uint16 "" 0 10 Predefined Number SMS Number 5

Call Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13080 Uint16 "" 0 10 Predefined Number Call Number 1
13081 Uint16 "" 0 10 Predefined Number Call Number 2
13082 Uint16 "" 0 10 Predefined Number Call Number 3
13083 Uint16 "" 0 10 Predefined Number Call Number 4
13084 Uint16 "" 0 10 Predefined Number Call Number 5
13066 Uint32 5 5 300 Seconds Call Answer Timeout
13054 Uint32 1 1 10 Number Call repeat

Movement Event

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
12106 Uint8 0 0 1 0 – Disable Scenario Settings
1 – Enable
12108 Uint8 0 0 1 0 – Movement Event Mode
1 – No Movement Event
12107 Uint32 30 30 65500 Seconds Timeout
7294 Uint16 "" 0 10 Predefined Number Send SMS to
8294 String Movement Event 0 160 Char SMS Text

DOUT Control Via Call

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
12000 Uint16 0 0 2 0 – None Scenario Settings
1 – DOUT1
2 – DOUT2
12002 Uint8 5 0 2147483648 seconds Duration Timeout

Immobilizer

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11700 Uint16 0 0 3 0 – Disable Scenario Settings
1 – Low Priority
2 – High Priority
3 – Panic Priority
11701 Uint16 1 0 1 0 – Disable Eventual Records
1 – Enable
11702 Uint16 0 0 2 0 – None Output Control
1 – DOUT1
2 – DOUT2
11703 Uint16 0 0 1 0 – Disable iButton List Check
1 – Enable
11709 Uint16 1 0 1 0 – Disable Depend on Ignition
1 – Enable
7140 Uint16 "" 0 10 Predefined number Send SMS to
8140 String Immobilizer 0 160 Char SMS text
60068 Uint8 30 1 65535 Seconds Ignition Off Timeout

iButton Read Notification

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11704 Uint16 0 0 2 0 – None Output Control
1 – DOUT1
2 – DOUT2
11705 Uint8 200 100 5000 Miliseconds DOUT ON Duration
11706 Uint16 0 0 1 0 – Disable iButton List Check
1 – Enable
11707 Uint16 0 0 1 0 – Disable Depend On Ignition
1 – Enable

DOUT Control Via Ignition

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13401 Uint16 0 0 2 0 – None DOUT Control
1 – DOUT1
2 – DOUT2
13402 Uint16 0 0 2 0 – None DOUT Deactivation Via DIN
1 – DOUT1
2 – DOUT2
13403 Uint8 5 0 65500 Seconds Ignition Off Timeout

Bluetooth Home Zone Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
322 Uint8 0 0 3 0 – None BLE Geofence
1 – ELA MOV
2 – Ela Sensors
3 – Beacons
324 Uint8 -60 -100 0 dBm Home Zone RSSI
329 Uint8 60 40 65535 Seconds Time-without-beacon
325 Uint8 0 0 2 0 – On Exit Generate Event
1 – On Entrance
2 – On both
326 Uint16 "" 0 10 Predefined Number Make Call To
7470 Uint16 "" 0 10 Predefined Number Send SMS to
8470 String Home Zone Alarm 0 160 Char SMS Text

Amber Alert

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
601 Uint8 1800 0 86400 Seconds Timeout
602 Uint8 300 0 86400 Seconds Pre-Alarm
603 Uint8 0 0 1 0 – Call Order Priority
1 – Record
607 Uint8 0 0 1 0 – Disable Deactivate after alarm call
1 – Enable
605 Uint16 "" 0 10 Predefined Number Initial call number
606 Uint16 "" 0 10 Predefined Number Alarm call number
7339 Uint16 "" 0 10 Predefined Number Send SMS to
8339 String %date %datetime Lon %flon LatP %flat Amber Alert Val %val Timout %param601 0 160 Char SMS Text

Proximity Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
327 Uint8 0 0 1 0 – Disable Proximity detection
1 – Enable
1116 Uint8 0 0 255 - Proximity Group ID
328 Uint8 -60 -100 0 dBm Proximity RSSI
331 Uint8 0 0 20 - Proximity RSSI exit threshold
332 Uint8 0 0 1 0 – Disable Proximity RSSI moving average enable
1 – Enable
333 Uint8 5 0 60 - Proximity RSSI moving average samples
330 Uint8 1 0 1 0 – Disable Proximity while charging
1 – Enable
7471 Uint16 "" 0 10 Predefined Number Send SMS to
8471 String Proximity 0 160 Char SMS Text

Lockdown Indication Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
323 Uint8 30 0 65500 Seconds Pre-Alarm

Last Known Position

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
51720 Uint8 0 0 1 0 – Disable Scenario Settings
1 – Enable

Tamper detection bracelet

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
321 Uint8 0 0 1 0 – Disable Tamper Detection
1 – Enable
320 Uint16 "" 0 10 Predefined Number Call to
7475 Uint16 "" 0 10 Predefined Number Send SMS to
8475 String Tamper 0 160 Char SMS Text