Accelerometer Features

Excessive Idling

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11200 Uint16 0 0 3 0 – Disable Scenario Settings
1 – Low Priority
2 – High Priority
3 – Panic Priority
11203 Uint16 1 0 1 0 – Disable Eventual Records
1 – Enable
11205 Uint8 300 0 3600 Seconds Time to Stopped
11206 Uint8 5 0 3600 Seconds Time to Moving
11204 Uint16 0 0 2 0 – None Output Control
1 – DOUT1
2 – DOUT2
11201 Uint8 200 100 5000 Miliseconds DOUT ON Duration
11202 Uint8 200 100 5000 Miliseconds DOUT OFF Duration
7033 Uint16 "" 0 10 Predefined number Send SMS to
8033 String Idling Event 0 160 Char SMS text

Towing Detection

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11600 Uint16 0 0 3 0 – Disable Scenario Settings
1 – Low Priority
2 – High Priority
3 – Panic Priority
11601 Uint16 1 0 1 0 – Disable Eventual Records
1 – Enable
11602 Uint8 5 0 65535 Minutes Activation Timeout
11605 Uint8 0,22 0,1 5 Minutes Event Timeout
11602 Uint8 5 0 65535 g Threshold
11606 Uint8 1 0,1 30 Degrees Angle
11605 Uint8 1000 1 5000 Miliseconds Duration
11604 Uint16 "" 0 10 Predefined number Make Call to
7035 Uint16 "" 0 10 Predefined number Send SMS to
8035 String Towing 0 160 Char SMS text

Crash Detection

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11400 Uint16 0 0 3 0 – Disable Scenario Settings
1 – Low Priority
2 – High Priority
3 – Panic Priority
11401 Uint8 5 0 1000 Miliseconds Duration
11401 Uint8 1500 100 6000 mg Threshold
7037 Uint16 "" 0 10 Predefined number Send SMS to
8037 String Crash 0 160 Char SMS text
11412 Uint16 0 0 1 0 – Disable Trace Filter
1 – Enable
11406 Uint16 0 0 2 0 – Disable Crash Filter
1 – Trace Changes
2 – Trace Full
11401 Uint8 100 20 200 Hz Trace ODR
11401 Uint8 5 2 15 Seconds Accel Duration
11401 Uint8 10 2 30 Seconds GNSS Duration