FMM150 General description

From Wiki Knowledge Base | Teltonika GPS
Revision as of 15:21, 30 March 2023 by Jonas.sterbavicius (talk | contribs) (→‎Basic characteristics)

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)
Main Page > CAN Trackers & Adapters > FMM150 > FMM150 Manual > FMM150 General description

FMM150 is a tracking terminal with GNSS and GSM connectivity, which is able to collect device coordinates and transfer them via GSM network to a server. This device is perfectly suitable for applications, which require the location acquirement of remote objects.

Package contents

The FMM150 device is supplied to the customer in a cardboard box containing all the equipment that is necessary for operation. The package contains:

  • FMM150 device;
  • Input and output power supply cable with 2x6 connection pins;
  • 3.7 V 170 mAh rechargeable Li-ion battery.

Basic characteristics

GSM / GPRS / GNSS features:

  • Quectel BG95-M3, Teltonika TM2500
  • SMS (text, data);
  • Technology LTE CAT M1/NB-IoT/GSM/GPRS/GNSS/BLUETOOTH;
  • Integrated GNSS receiver;
  • Up to -165 dBm GNSS receiver sensitivity.

CELLULAR:

Technology Supported bands
2G bands BG95-M3: B2/B3/B5/B8
4G bands BG95-M3: LTE-FDD (CAT M1):

B1/B2/B3/B4/B5/B8/B12/B13/B18/B19/B20/B25/B27/B28/B66/B85

LTE-FDD (CAT NB2):

B1/B2/B3/B4/B5/B8/B12/B13/B18/B19/B20/B25/B28/B66/B71/B85 GSM: 850/900/1800/1900

Data transfer LTE: Max. 588Kbps (DL)/Max.1119Kbps (UL)
GPRS: Max. 107Kbps (DL)/Max. 85.6Kbps (UL)

Transmit power:

Class 4 for GSM850/900: 23±2dBm

Class 1 for GSM1800/1900: 20±2dBm

Class 3 for LTE-TDD: 23±2.7dBm

Class 3 for LTE-FDD: 23±2.7dBm


Hardware features:

  • Built-in CAN data processor;
  • Built-in movement sensor;
  • Built-in Bluetooth 4.0 LE;
  • Internal High Gain GNSS antenna;
  • Internal High Gain GSM antenna;
  • Internal flash memory 128MB (422 400 Records);
  • 170 mAh Li-ion rechargeable 3.7 V battery.


Interface features:

  • Power supply: +10...+30 V;
  • 2 CAN lines;
  • 1 digital inputs;
  • 1 configurable input DIN2 with ground sense or AIN1;
  • 1 configurable input DIN3 or AIN2;
  • 2 open collector digital outputs (connecting external relays, LED, buzzers etc);
  • 1-Wire temperature sensor;
  • 1-Wire iButton;
  • 3 LEDs indicating device status.


Special features:

  • Fast position fix (Outdoor areas);
  • High Quality track even in high density urban canyon;
  • Ultra small case;
  • Ready for harsh environment;
  • Easy to mount in limited access areas;
  • Firmly fasten;
  • 2 LED status indication;
  • Real time tracking;
  • Smart data acquisition based on:
    • Time;
    • Speed;
    • Angle;
    • Distance;
    • Ignition or any other I/O event;
  • Sending acquired data via GPRS;
  • GPRS and SMS I/O events;
  • Virtual odometer;
  • Jamming detection;
  • Configurable using Secured SMS Commands;
  • Color ribbon non-detachable cable;
  • Overvoltage protection;


Description Voltage Duration
Normal operation

+10 ... +30 V

Unlimited

Protection turns on, device turns off 34 V Unlimited
Maximum voltage < 70 V Unlimited
Maximum voltage impulse 90 V 5 ms



Technical features


Part name Physical specification
Navigation indication LED
Modem indication LED
CAN indication LED
Socket Soldered inner socket
USB Micro USB socket
GNSS Internal GNSS antenna
GSM Internal GSM antenna


Technical details
2 W max.
Current consumption at 12 V (Power supply 6...30 V DC)
GPRS: average 73.6 mA
Nominal: average 25.2 mA
GNSS sleep: average 11.6 mA
Deep Sleep: average 5.3 mA
Online Deep Sleep: average 5.6 mA
Ultra Deep Sleep: average 3.5 mA
Battery charge current Average 140 mA
Operating temperature (without battery) -40..+85 °C
Storage temperature (without battery) -40..+85 °C
Storage relative humidity 5..95% (no condensation)
Device + case + battery weight 55 g


Dimension drawing:

FMB130 dimension.png


Technical information about internal battery


Internal back-up battery Battery voltage (V) Nominal Capacity (mAh) Power (Wh) Charge temperature (°C) Discharge temperature (°C) Storage temperature (°C)
Li-ion rechargeable battery 3.75~3.90 170 0.64 – 0.66 0 to +45 -20 to +60 -20 to +45 for 1 month
-20 to +35 for 6 months

Batteries are covered by 6 month warranty support.

Bw nb.png CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.
Bw disposal.png Battery should not be disposed of into general household waste.
Bring damaged or worn-out batteries to your local recycling center or dispose them into a battery recycle bin commonly found in supermarkets.

Electrical characteristics


Characteristic description Value
Min. Typ. Max. Unit
Supply Voltage:
Supply Voltage
(Recommended Operating Conditions)
+10 +30 V
Digital Output (Open Drain grade):
Drain current (Digital Output OFF) 120 µA
Drain current
(Digital Output ON, Recommended Operating Conditions)
0.1 0.5 A
Static Drain-Source resistance
(Digital Output ON)
400 600
Digital Input:
Input resistance (DIN1) 47
Input resistance (DIN2) 38.45
Input resistance (DIN3) 47
Input voltage
(Recommended Operating Conditions)
0 Supply voltage V
Input Voltage threshold (DIN1) 7.5 V
Input Voltage threshold (DIN2) 2.5 V
Input Voltage threshold (DIN3) 2.5 V
Analog Input:
Input voltage
(Recommended Operating Conditions), Range 1
0 +10 V
Input resistance, Range 1 38.45
Measurement error on 12V, Range 1 3 %
Additional error on 12 V, Range 1 360 mV
Measurement error on 30 V, Range 1 3 %
Additional error on 30 V, Range 1 900 mV
Input Voltage
(Recommended Operating Conditions), Range 2
0 +30 V
Input resistance, Range 2 38.45
Measurement error on 12V, Range 2 3 %
Additional error on 12 V, Range 2 360 mV
Measurement error on 30 V, Range 2 3 %
Additional error on 30 V, Range 2 900 mV
Output Supply Voltage 1-Wire:
Supply voltage +4.5 +4.7 V
Output inner resistance 7 Ω
Output current (Uout > 3.0 V) 30 mA
Short circuit current (Uout = 0) 75 mA
Ground sense:
Input resistance 38.45
Input voltage
(Recommended operating conditions)
0 Supply voltage V
Input voltage threshold 0.5 V
Sink current 180 nA


CAN interface:
Internal terminal resistor CAN bus
(no internal termination resistor)
- - - Ω
Differential input resistance 19 30 52
Recessive output voltage 2 2.5 3 V
Differential receiver threshold Voltage 0.5 0.7 0.9 V
Common mode input voltage -30 - 30 V


Alert.png
Analog Input error margin can increase if temperature varies.

Absolute maximum ratings

Characteristic description Value
Min. Typ. Max. Unit
Supply Voltage
(Absolute Maximum Ratings)
-32 +32 V
Drain-Source clamp threshold voltage
(Absolute Maximum Ratings), (Idrain = 2 mA)
+36 V
Digital Input Voltage
(Absolute Maximum Ratings)
-32 +32 V
Analog Input Voltage
(Absolute Maximum Ratings)
-32 +32 V