Template:FMB1 Electrical characteristics

From Wiki Knowledge Base | Teltonika GPS
Revision as of 09:23, 26 April 2018 by Atabasnikov (talk | contribs) (Created page with "{| class="wikitable" |+ ! style="width: 400px; background: black; color: white;" rowspan=2 | Characteristic description ! style="width: 300px; background: black; color: white;...")

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)
Characteristic description Value
Min. Typ. Max. Unit
Supply Voltage:
Supply Voltage (Recommended Operating Conditions) +10 +30 V
Digital Output (Open Drain grade):
Drain current (Digital Output OFF) 120 µA
Drain current (Digital Output ON, Recommended Operating Conditions) 0.1 0.5 A
Static Drain-Source resistance (Digital Output ON) 400 600
Digital Input:
Input resistance (DIN1) 47
Input resistance (DIN1) 47
Input voltage (Recommended Operating Conditions) 0 Supply voltage V
Input Voltage threshold (DIN1) 7.5 V
Input Voltage threshold (DIN2) 2.5 V
Analog Input:
Input voltage (Recommended Operating Conditions), Range 1 0 +10 V
Input resistance, Range 1 150
Measurement error on 12V, Range 1 0.9 %
Additional error on 12 V, Range 1 108 mV
Measurement error on 30 V, Range 1 0.33 %
Additional error on 30 V, Range 1 88 mV
Input Voltage (Recommended Operating Conditions), Range 2 0 +30 V
Input resistance, Range 2 150
Measurement error on 12 V, Range 2 0.9 %
Additional error on 12 V, Range 2 108 mV
Measurement error on 30 V, Range 2 0.33 %
Additional error on 30 V, Range 2 88 mV
Output Supply Voltage 1-Wire:
Supply voltage +4.5 +4.7 V
Output inner resistance 7 Ω
Output current (Uout > 3.0 V) 30 mA
Short circuit current (Uout = 0) 75 mA


Bw nb.png Analog Input error margin can increase if temperature varies.