Template:SAS device Parameter list - Features

From Wiki Knowledge Base | Teltonika GPS

Features

Eco/Green Driving

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11000 Uint16 0 0 3 0 – Disable Scenario Settings
1 – Low Priority
2 – High Priority
3 – Panic Priority
11004 Uint8 2,2 0,5 10 m/s² Max acceleration
11005 Uint8 2,5 0,5 10 m/s² Max Braking
11006 Uint8 2,1 0,5 10 rad/s Max Cornering
11007 Uint16 0 0 1 0 – GPS Source
1 – Accelerometer
11008 Uint16 0 0 1 0 – Disable Eco/Green Driving Duration
1 – Enable
11003 Uint16 0 0 2 0 – None Output Control
1 – DOUT1
2 – DOUT2
11001 Uint8 200 100 5000 miliseconds DOUT ON Duration
11002 Uint8 200 0 5000 miliseconds DOUT OFF Duration
7034 Uint16 "" 0 10 Predefined number Send SMS to
8034 String Green Driving 0 160 Char SMS text

Jamming

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11300 Uint8 0 0 3 0 – Disable Scenario Settings
1 – Low Priority
2 – High Priority
3 – Panic Priority
11303 Uint8 1 0 1 0 – Disable Eventual Records
1 – Enable
11305 Uint8 60 0 65535 Seconds Time until Jamming Event Detection

Unauthorized movement

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11720 Uint8 0 0 3 0 – Disable Scenario Settings
1 – Low Priority
2 – High Priority
3 – Panic Priority
11721 Uint8 0 0 1 0 – On Exit UGenerate aven
1 – On Entrance
2 – On Both
11722 Uint8 1 0 30 Seconds Pre-alarm timeout
11723 Uint8 1 0 30 Seconds Time to Stable
11724 Uint8 1 1 5 Seconds Buzzer ON
11725 Uint8 5 2 30 Seconds Buzzer period
7729 Uint16 "" 0 10 Predefined number Send SMS to
8729 String Unauthorized movement 0 160 Char SMS Text

Over speeding

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11100 Uint8 0 0 3 0 – Disable Scenario Settings
1 – Low Priority
2 – High Priority
3 – Panic Priority
11104 Uint32 90 0 6 km/h Max speed
11103 Uint16 0 0 2 0 – None Output Control
1 – DOUT1
2 – DOUT2
11101 Uint8 200 100 5000 miliseconds DOUT ON Duration
11102 Uint8 200 0 5000 miliseconds DOUT OFF Duration
7032 Uint16 "" 0 10 Predefined Number Send SMS to
8032 String Overspeeding 0 160 Char SMS Text

Alarm

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
7245 Uint16 "" 0 10 Predefined Number Send SMS to
8245 String Alarm 0 160 Char SMS Text
11711 Uint8 0 0 1 0 – Call Order priority
1 – Record
11712 Uint16 "" 0 10 Predefined Number Call to

Additional features

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
251 Uint32 0 0 4294967295 number User ID

Power Off/On

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13086 Uint8 "" 0 2 0 – Disable Event On Power Off
1 – Enable
7310 Uint16 "" 0 10 Predefined Number Send SMS to
8310 String Power! Val %val IM %imei 0 160 Char SMS Text

ManDown

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
12100 Uint8 0 0 1 0 – Disable Scenario Settings
1 – Enable
127 Uint8 0 0 1 0 – Disable Mandown/No/Movement while charging
1 – Enable
12110 Uint8 1 0 2 0 – On Exit Generate event
1 – On Entrance
2 – On both
12101 Uint8 0 0 1 0 – Horizontal Position
1 – Vertical
12102 Uint32 60 30 150 Degrees Angle
12111 Uint32 5 0 600 Seconds Silent pre-alarm delay
12103 Uint32 3 0 65500 Seconds Pre-alarm timeout
7222 Uint16 "" 0 10 Predefined Number Send SMS to
8222 String ManDown 0 160 Char SMS Text
12104 Uint8 0 0 1 0 – Call Order priority
1 – Record
12105 Uint16 "" 0 10 Predefined Number Call to

Last Known Position

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
51720 Uint8 0 0 1 0 – Disable Scenario Settings
1 – Enable

Unplug Detection

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11500 Uint8 0 0 3 0 – Disable Scenario Settings
1 – Low Priority
2 – High Priority
3 – Panic Priority
11501 Uint8 1 0 1 0 – Disable Eventual Records
1 – Enable
11502 Uint8 0 0 1 0 – Simple Unplug Detection Mode
1 – Advanced
11504 Uint8 0 0 1 0 – Disable Buzzer Control
1 – Enable
11505 Uint8 200 0 65535 Seconds Buzzer ON duration
7036 Uint16 "" 0 10 Predefined number Send SMS to
8036 String Unplug 0 160 Char SMS Text

SIM Card Tamper Protection

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11730 Uint8 0 0 1 0 – Disable Enable/Disable SIM Tamper Protection
1 – Enable
11731 Uint8 0 0 3600 Seconds ICCID

Event Notification

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13053 Uint8 "" 0 7 0 – None Event Notification
1 – Alarm
2 – ManDown
3 – ManDown & Alarm
4 – Movement Event
5 – Movement Event & Alarm
6 – Movement Event & ManDown
7 – Movement Event & ManDown & Alarm
60257 Uint8 0 0 1 0 – GPRS or SMS SMS sending method
1 – GPRS and SMS
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13059 Uint8 "" 0 1 0 – Nobody Call After Answer
1 – Number 2
2 – Number 2 + Number 3
3 – Number 2 + Number 3 + Number 4
4 – Number 2 + Number 3 + Number 4 + Number 5
5 – Number 3
6 – Number 3 + Number 4
7 – Number 3 + Number 4 + Number 5
8 – Number 4
9 – Number 4 + Number 5
10 – Number 5
13055 Uint8 0 0 1 0 – Disable Inform When Answered
1 – Enable
13057 String Answered 0 160 Char SMS Text
13056 Uint8 0 0 1 0 – Disable Inform When Not Answered
1 – Enable
13058 String No answer 0 160 Char SMS Text

SMS Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13060 Uint16 "" 0 10 Predefined Number SMS Number 1
13061 Uint16 "" 0 10 Predefined Number SMS Number 2
13062 Uint16 "" 0 10 Predefined Number SMS Number 3
13063 Uint16 "" 0 10 Predefined Number SMS Number 4
13064 Uint16 "" 0 10 Predefined Number SMS Number 5

Call Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13080 Uint16 "" 0 10 Predefined Number Call Number 1
13081 Uint16 "" 0 10 Predefined Number Call Number 2
13082 Uint16 "" 0 10 Predefined Number Call Number 3
13083 Uint16 "" 0 10 Predefined Number Call Number 4
13084 Uint16 "" 0 10 Predefined Number Call Number 5
13066 Uint32 5 5 300 Seconds Call Answer Timeout
13054 Uint32 1 1 10 Number Call repeat

Movement Event

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
12106 Uint8 0 0 1 0 – Disable Scenario Settings
1 – Enable
12108 Uint8 0 0 1 0 – Movement Event Mode
1 – No Movement Event
12107 Uint32 30 30 65500 Seconds Timeout
7294 Uint16 "" 0 10 Predefined Number Send SMS to
8294 String Movement Event 0 160 Char SMS Text

DOUT Control Via Call

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
12000 Uint16 0 0 2 0 – None Scenario Settings
1 – DOUT1
2 – DOUT2
12002 Uint8 5 0 2147483648 seconds Duration Timeout

Immobilizer

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11700 Uint16 0 0 3 0 – Disable Scenario Settings
1 – Low Priority
2 – High Priority
3 – Panic Priority
11701 Uint16 1 0 1 0 – Disable Eventual Records
1 – Enable
11702 Uint16 0 0 2 0 – None Output Control
1 – DOUT1
2 – DOUT2
11703 Uint16 0 0 1 0 – Disable iButton List Check
1 – Enable
11709 Uint16 1 0 1 0 – Disable Depend on Ignition
1 – Enable
7140 Uint16 "" 0 10 Predefined number Send SMS to
8140 String Immobilizer 0 160 Char SMS text
60068 Uint8 30 1 65535 Seconds Ignition Off Timeout

iButton Read Notification

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11704 Uint16 0 0 2 0 – None Output Control
1 – DOUT1
2 – DOUT2
11705 Uint8 200 100 5000 Miliseconds DOUT ON Duration
11706 Uint16 0 0 1 0 – Disable iButton List Check
1 – Enable
11707 Uint16 0 0 1 0 – Disable Depend On Ignition
1 – Enable

DOUT Control Via Ignition

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13401 Uint16 0 0 2 0 – None DOUT Control
1 – DOUT1
2 – DOUT2
13402 Uint16 0 0 2 0 – None DOUT Deactivation Via DIN
1 – DOUT1
2 – DOUT2
13403 Uint8 5 0 65500 Seconds Ignition Off Timeout

Bluetooth Home Zone Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
322 Uint8 0 0 3 0 – None BLE Geofence
1 – ELA MOV
2 – Ela Sensors
3 – Beacons
324 Uint8 -60 -100 0 dBm Home Zone RSSI
329 Uint8 60 40 65535 Seconds Time-without-beacon
325 Uint8 0 0 2 0 – On Exit Generate Event
1 – On Entrance
2 – On both
326 Uint16 "" 0 10 Predefined Number Make Call To
7470 Uint16 "" 0 10 Predefined Number Send SMS to
8470 String Home Zone Alarm 0 160 Char SMS Text

EYE Sensors filtered by Name List

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
70076 Uint8 0 0 3 0 – Disabled Sensor Configuration
1 – Custom Sensors
2 – EYE Sensors
3 – Custom and EYE Sensors
70077 Uint8 0 0 3 0 – Disabled EYE Sensor Filter
1 – Name
2 – MAC
3 – Name and MAC
70057 Uint16 10 0 65535 Defines period in seconds, for how long sensor has to be not detected in order to remove it from EYE Sensor List. Data clear period
70005 Int8 0 0 -100 Defines period in seconds, for how long sensor has to be not detected in order to remove it from EYE Sensor List. RSSI
258 Uint32 60 0 2592000 Defines how often to create EYE Sensor List records while vehicle is moving in seconds On Move
259 Uint32 60 0 2592000 Defines how often to create EYE Sensor List records while vehicle is not moving in seconds On Stop
70067 Uint32 60 0 2592000 Defines how often to create EYE Sensor List records while vehicle is not moving in seconds Temperature


Amber Alert

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
601 Uint8 1800 0 86400 Seconds Timeout
602 Uint8 300 0 86400 Seconds Pre-Alarm
603 Uint8 0 0 1 0 – Call Order Priority
1 – Record
607 Uint8 0 0 1 0 – Disable Deactivate after alarm call
1 – Enable
605 Uint16 "" 0 10 Predefined Number Initial call number
606 Uint16 "" 0 10 Predefined Number Alarm call number
7339 Uint16 "" 0 10 Predefined Number Send SMS to
8339 String %date %datetime Lon %flon LatP %flat Amber Alert Val %val Timout %param601 0 160 Char SMS Text

Proximity Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
327 Uint8 0 0 1 0 – Disable Proximity detection
1 – Enable
1116 Uint8 0 0 255 - Proximity Group ID
328 Uint8 -60 -100 0 dBm Proximity RSSI
331 Uint8 0 0 20 - Proximity RSSI exit threshold
332 Uint8 0 0 1 0 – Disable Proximity RSSI moving average enable
1 – Enable
333 Uint8 5 0 60 - Proximity RSSI moving average samples
330 Uint8 1 0 1 0 – Disable Proximity while charging
1 – Enable
7471 Uint16 "" 0 10 Predefined Number Send SMS to
8471 String Proximity 0 160 Char SMS Text

Lockdown Indication Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
323 Uint8 30 0 65500 Seconds Pre-Alarm

Last Known Position

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
51720 Uint8 0 0 1 0 – Disable Scenario Settings
1 – Enable

Tamper detection bracelet

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
321 Uint8 0 0 1 0 – Disable Tamper Detection
1 – Enable
320 Uint16 "" 0 10 Predefined Number Call to
7475 Uint16 "" 0 10 Predefined Number Send SMS to