From Wiki Knowledge Base | Teltonika GPS
(
diff)
← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)
Features
Eco/Green Driving
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
11000
|
Uint16
|
0
|
0
|
3
|
0 – Disable
|
Scenario Settings
|
1 – Low Priority
|
2 – High Priority
|
3 – Panic Priority
|
11004
|
Uint8
|
2,2
|
0,5
|
10
|
m/s²
|
Max acceleration
|
11005
|
Uint8
|
2,5
|
0,5
|
10
|
m/s²
|
Max Braking
|
11006
|
Uint8
|
2,1
|
0,5
|
10
|
rad/s
|
Max Cornering
|
11007
|
Uint16
|
0
|
0
|
1
|
0 – GPS
|
Source
|
1 – Accelerometer
|
11008
|
Uint16
|
0
|
0
|
1
|
0 – Disable
|
Eco/Green Driving Duration
|
1 – Enable
|
11003
|
Uint16
|
0
|
0
|
2
|
0 – None
|
Output Control
|
1 – DOUT1
|
2 – DOUT2
|
11001
|
Uint8
|
200
|
100
|
5000
|
miliseconds
|
DOUT ON Duration
|
11002
|
Uint8
|
200
|
0
|
5000
|
miliseconds
|
DOUT OFF Duration
|
7034
|
Uint16
|
""
|
0
|
10
|
Predefined number
|
Send SMS to
|
8034
|
String
|
Green Driving
|
0
|
160
|
Char
|
SMS text
|
Jamming
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
11300
|
Uint8
|
0
|
0
|
3
|
0 – Disable
|
Scenario Settings
|
1 – Low Priority
|
2 – High Priority
|
3 – Panic Priority
|
11303
|
Uint8
|
1
|
0
|
1
|
0 – Disable
|
Eventual Records
|
1 – Enable
|
11305
|
Uint8
|
60
|
0
|
65535
|
Seconds
|
Time until Jamming Event Detection
|
Unauthorized movement
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
11720
|
Uint8
|
0
|
0
|
3
|
0 – Disable
|
Scenario Settings
|
1 – Low Priority
|
2 – High Priority
|
3 – Panic Priority
|
11721
|
Uint8
|
0
|
0
|
1
|
0 – On Exit
|
UGenerate aven
|
1 – On Entrance
|
2 – On Both
|
11722
|
Uint8
|
1
|
0
|
30
|
Seconds
|
Pre-alarm timeout
|
11723
|
Uint8
|
1
|
0
|
30
|
Seconds
|
Time to Stable
|
11724
|
Uint8
|
1
|
1
|
5
|
Seconds
|
Buzzer ON
|
11725
|
Uint8
|
5
|
2
|
30
|
Seconds
|
Buzzer period
|
7729
|
Uint16
|
""
|
0
|
10
|
Predefined number
|
Send SMS to
|
8729
|
String
|
Unauthorized movement
|
0
|
160
|
Char
|
SMS Text
|
Over speeding
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
11100
|
Uint8
|
0
|
0
|
3
|
0 – Disable
|
Scenario Settings
|
1 – Low Priority
|
2 – High Priority
|
3 – Panic Priority
|
11104
|
Uint32
|
90
|
0
|
6
|
km/h
|
Max speed
|
11103
|
Uint16
|
0
|
0
|
2
|
0 – None
|
Output Control
|
1 – DOUT1
|
2 – DOUT2
|
11101
|
Uint8
|
200
|
100
|
5000
|
miliseconds
|
DOUT ON Duration
|
11102
|
Uint8
|
200
|
0
|
5000
|
miliseconds
|
DOUT OFF Duration
|
7032
|
Uint16
|
""
|
0
|
10
|
Predefined Number
|
Send SMS to
|
8032
|
String
|
Overspeeding
|
0
|
160
|
Char
|
SMS Text
|
Alarm
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
7245
|
Uint16
|
""
|
0
|
10
|
Predefined Number
|
Send SMS to
|
8245
|
String
|
Alarm
|
0
|
160
|
Char
|
SMS Text
|
11711
|
Uint8
|
0
|
0
|
1
|
0 – Call
|
Order priority
|
1 – Record
|
11712
|
Uint16
|
""
|
0
|
10
|
Predefined Number
|
Call to
|
Additional features
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
251
|
Uint32
|
0
|
0
|
4294967295
|
number
|
User ID
|
Power Off/On
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
13086
|
Uint8
|
""
|
0
|
2
|
0 – Disable
|
Event On Power Off
|
1 – Enable
|
7310
|
Uint16
|
""
|
0
|
10
|
Predefined Number
|
Send SMS to
|
8310
|
String
|
Power! Val %val IM %imei
|
0
|
160
|
Char
|
SMS Text
|
ManDown
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
12100
|
Uint8
|
0
|
0
|
1
|
0 – Disable
|
Scenario Settings
|
1 – Enable
|
127
|
Uint8
|
0
|
0
|
1
|
0 – Disable
|
Mandown/No/Movement while charging
|
1 – Enable
|
12110
|
Uint8
|
1
|
0
|
2
|
0 – On Exit
|
Generate event
|
1 – On Entrance
|
2 – On both
|
12101
|
Uint8
|
0
|
0
|
1
|
0 – Horizontal
|
Position
|
1 – Vertical
|
12102
|
Uint32
|
60
|
30
|
150
|
Degrees
|
Angle
|
12111
|
Uint32
|
5
|
0
|
600
|
Seconds
|
Silent pre-alarm delay
|
12103
|
Uint32
|
3
|
0
|
65500
|
Seconds
|
Pre-alarm timeout
|
7222
|
Uint16
|
""
|
0
|
10
|
Predefined Number
|
Send SMS to
|
8222
|
String
|
ManDown
|
0
|
160
|
Char
|
SMS Text
|
12104
|
Uint8
|
0
|
0
|
1
|
0 – Call
|
Order priority
|
1 – Record
|
12105
|
Uint16
|
""
|
0
|
10
|
Predefined Number
|
Call to
|
Last Known Position
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
51720
|
Uint8
|
0
|
0
|
1
|
0 – Disable
|
Scenario Settings
|
1 – Enable
|
Unplug Detection
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
11500
|
Uint8
|
0
|
0
|
3
|
0 – Disable
|
Scenario Settings
|
1 – Low Priority
|
2 – High Priority
|
3 – Panic Priority
|
11501
|
Uint8
|
1
|
0
|
1
|
0 – Disable
|
Eventual Records
|
1 – Enable
|
11502
|
Uint8
|
0
|
0
|
1
|
0 – Simple
|
Unplug Detection Mode
|
1 – Advanced
|
11504
|
Uint8
|
0
|
0
|
1
|
0 – Disable
|
Buzzer Control
|
1 – Enable
|
11505
|
Uint8
|
200
|
0
|
65535
|
Seconds
|
Buzzer ON duration
|
7036
|
Uint16
|
""
|
0
|
10
|
Predefined number
|
Send SMS to
|
8036
|
String
|
Unplug
|
0
|
160
|
Char
|
SMS Text
|
SIM Card Tamper Protection
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
11730
|
Uint8
|
0
|
0
|
1
|
0 – Disable
|
Enable/Disable SIM Tamper Protection
|
1 – Enable
|
11731
|
Uint8
|
0
|
0
|
3600
|
Seconds
|
ICCID
|
Event Notification
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
13053
|
Uint8
|
""
|
0
|
7
|
0 – None
|
Event Notification
|
1 – Alarm
|
2 – ManDown
|
3 – ManDown & Alarm
|
4 – Movement Event
|
5 – Movement Event & Alarm
|
6 – Movement Event & ManDown
|
7 – Movement Event & ManDown & Alarm
|
60257
|
Uint8
|
0
|
0
|
1
|
0 – GPRS or SMS
|
SMS sending method
|
1 – GPRS and SMS
|
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
13059
|
Uint8
|
""
|
0
|
1
|
0 – Nobody
|
Call After Answer
|
1 – Number 2
|
2 – Number 2 + Number 3
|
3 – Number 2 + Number 3 + Number 4
|
4 – Number 2 + Number 3 + Number 4 + Number 5
|
5 – Number 3
|
6 – Number 3 + Number 4
|
7 – Number 3 + Number 4 + Number 5
|
8 – Number 4
|
9 – Number 4 + Number 5
|
10 – Number 5
|
13055
|
Uint8
|
0
|
0
|
1
|
0 – Disable
|
Inform When Answered
|
1 – Enable
|
13057
|
String
|
Answered
|
0
|
160
|
Char
|
SMS Text
|
13056
|
Uint8
|
0
|
0
|
1
|
0 – Disable
|
Inform When Not Answered
|
1 – Enable
|
13058
|
String
|
No answer
|
0
|
160
|
Char
|
SMS Text
|
SMS Settings
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
13060
|
Uint16
|
""
|
0
|
10
|
Predefined Number
|
SMS Number 1
|
13061
|
Uint16
|
""
|
0
|
10
|
Predefined Number
|
SMS Number 2
|
13062
|
Uint16
|
""
|
0
|
10
|
Predefined Number
|
SMS Number 3
|
13063
|
Uint16
|
""
|
0
|
10
|
Predefined Number
|
SMS Number 4
|
13064
|
Uint16
|
""
|
0
|
10
|
Predefined Number
|
SMS Number 5
|
Call Settings
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
13080
|
Uint16
|
""
|
0
|
10
|
Predefined Number
|
Call Number 1
|
13081
|
Uint16
|
""
|
0
|
10
|
Predefined Number
|
Call Number 2
|
13082
|
Uint16
|
""
|
0
|
10
|
Predefined Number
|
Call Number 3
|
13083
|
Uint16
|
""
|
0
|
10
|
Predefined Number
|
Call Number 4
|
13084
|
Uint16
|
""
|
0
|
10
|
Predefined Number
|
Call Number 5
|
13066
|
Uint32
|
5
|
5
|
300
|
Seconds
|
Call Answer Timeout
|
13054
|
Uint32
|
1
|
1
|
10
|
Number
|
Call repeat
|
Movement Event
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
12106
|
Uint8
|
0
|
0
|
1
|
0 – Disable
|
Scenario Settings
|
1 – Enable
|
12108
|
Uint8
|
0
|
0
|
1
|
0 – Movement Event
|
Mode
|
1 – No Movement Event
|
12107
|
Uint32
|
30
|
30
|
65500
|
Seconds
|
Timeout
|
7294
|
Uint16
|
""
|
0
|
10
|
Predefined Number
|
Send SMS to
|
8294
|
String
|
Movement Event
|
0
|
160
|
Char
|
SMS Text
|
DOUT Control Via Call
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
12000
|
Uint16
|
0
|
0
|
2
|
0 – None
|
Scenario Settings
|
1 – DOUT1
|
2 – DOUT2
|
12002
|
Uint8
|
5
|
0
|
2147483648
|
seconds
|
Duration Timeout
|
Immobilizer
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
11700
|
Uint16
|
0
|
0
|
3
|
0 – Disable
|
Scenario Settings
|
1 – Low Priority
|
2 – High Priority
|
3 – Panic Priority
|
11701
|
Uint16
|
1
|
0
|
1
|
0 – Disable
|
Eventual Records
|
1 – Enable
|
11702
|
Uint16
|
0
|
0
|
2
|
0 – None
|
Output Control
|
1 – DOUT1
|
2 – DOUT2
|
11703
|
Uint16
|
0
|
0
|
1
|
0 – Disable
|
iButton List Check
|
1 – Enable
|
11709
|
Uint16
|
1
|
0
|
1
|
0 – Disable
|
Depend on Ignition
|
1 – Enable
|
7140
|
Uint16
|
""
|
0
|
10
|
Predefined number
|
Send SMS to
|
8140
|
String
|
Immobilizer
|
0
|
160
|
Char
|
SMS text
|
60068
|
Uint8
|
30
|
1
|
65535
|
Seconds
|
Ignition Off Timeout
|
iButton Read Notification
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
11704
|
Uint16
|
0
|
0
|
2
|
0 – None
|
Output Control
|
1 – DOUT1
|
2 – DOUT2
|
11705
|
Uint8
|
200
|
100
|
5000
|
Miliseconds
|
DOUT ON Duration
|
11706
|
Uint16
|
0
|
0
|
1
|
0 – Disable
|
iButton List Check
|
1 – Enable
|
11707
|
Uint16
|
0
|
0
|
1
|
0 – Disable
|
Depend On Ignition
|
1 – Enable
|
DOUT Control Via Ignition
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
13401
|
Uint16
|
0
|
0
|
2
|
0 – None
|
DOUT Control
|
1 – DOUT1
|
2 – DOUT2
|
13402
|
Uint16
|
0
|
0
|
2
|
0 – None
|
DOUT Deactivation Via DIN
|
1 – DOUT1
|
2 – DOUT2
|
13403
|
Uint8
|
5
|
0
|
65500
|
Seconds
|
Ignition Off Timeout
|
Bluetooth Home Zone Settings
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
322
|
Uint8
|
0
|
0
|
3
|
0 – None
|
BLE Geofence
|
1 – ELA MOV
|
2 – Ela Sensors
|
3 – Beacons
|
324
|
Uint8
|
-60
|
-100
|
0
|
dBm
|
Home Zone RSSI
|
329
|
Uint8
|
60
|
40
|
65535
|
Seconds
|
Time-without-beacon
|
325
|
Uint8
|
0
|
0
|
2
|
0 – On Exit
|
Generate Event
|
1 – On Entrance
|
2 – On both
|
326
|
Uint16
|
""
|
0
|
10
|
Predefined Number
|
Make Call To
|
7470
|
Uint16
|
""
|
0
|
10
|
Predefined Number
|
Send SMS to
|
8470
|
String
|
Home Zone Alarm
|
0
|
160
|
Char
|
SMS Text
|
EYE Sensors filtered by Name List
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
70076
|
Uint8
|
0
|
0
|
3
|
0 – Disabled
|
Sensor Configuration
|
1 – Custom Sensors
|
2 – EYE Sensors
|
3 – Custom and EYE Sensors
|
70077
|
Uint8
|
0
|
0
|
3
|
0 – Disabled
|
EYE Sensor Filter
|
1 – Name
|
2 – MAC
|
3 – Name and MAC
|
Data Clear Period
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
70057
|
Uint16
|
10
|
0
|
65535
|
Defines period in seconds, for how long sensor has to be not detected in order to remove it from EYE Sensor List.
|
Data clear period
|
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
70005
|
Int8
|
0
|
0
|
-100
|
Defines period in seconds, for how long sensor has to be not detected in order to remove it from EYE Sensor List.
|
Data clear period
|
Record Period parameters
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
258
|
Uint32
|
60
|
0
|
2592000
|
Defines how often to create EYE Sensor List records while vehicle is moving in seconds
|
On Move
|
259
|
Uint32
|
60
|
0
|
2592000
|
Defines how often to create EYE Sensor List records while vehicle is not moving in seconds
|
On Stop
|
EYE Sensor Settings
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
70067
|
Bool
|
0
|
0
|
1
|
Includes temperature value, received from EYE Sensor
|
Temperature
|
70068
|
Bool
|
0
|
0
|
1
|
Includes humidity value, received from EYE Sensor
|
Humidity
|
70069
|
Bool
|
0
|
0
|
1
|
Includes magnetic field presence value around EYE sensor
|
Magnet
|
70083
|
Bool
|
0
|
0
|
1
|
Includes value, which represents how many times EYE Sensor has detected magnetic sensor trigger
|
Magnet Trigger Count
|
70070
|
Bool
|
0
|
0
|
1
|
Includes movement value, which displays if EYE Sensor is detecting movement
|
Movement
|
70071
|
Bool
|
0
|
0
|
1
|
Includes value, which represents how many times EYE Sensor has detected movement
|
Movement Count
|
70072
|
Bool
|
0
|
0
|
1
|
Includes pitch value, received from EYE Sensor accelerometer
|
Pitch
|
70073
|
Bool
|
0
|
0
|
1
|
Includes roll value, received from EYE Sensor accelerometer
|
Roll
|
70074
|
Bool
|
0
|
0
|
1
|
Includes low battery value received from EYE Sensor.
|
Low Battery
|
70075
|
Bool
|
0
|
0
|
1
|
Includes EYE Sensor battery voltage
|
Battery Voltage
|
EYE Name List
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
70006...70030
|
Char
|
-
|
0 characters
|
10 characters
|
Configure up to 50 different EYE Sensor Name filters
|
EYE Name List
|
Amber Alert
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
601
|
Uint8
|
1800
|
0
|
86400
|
Seconds
|
Timeout
|
602
|
Uint8
|
300
|
0
|
86400
|
Seconds
|
Pre-Alarm
|
603
|
Uint8
|
0
|
0
|
1
|
0 – Call
|
Order Priority
|
1 – Record
|
607
|
Uint8
|
0
|
0
|
1
|
0 – Disable
|
Deactivate after alarm call
|
1 – Enable
|
605
|
Uint16
|
""
|
0
|
10
|
Predefined Number
|
Initial call number
|
606
|
Uint16
|
""
|
0
|
10
|
Predefined Number
|
Alarm call number
|
7339
|
Uint16
|
""
|
0
|
10
|
Predefined Number
|
Send SMS to
|
8339
|
String
|
%date %datetime Lon %flon LatP %flat Amber Alert Val %val Timout %param601
|
0
|
160
|
Char
|
SMS Text
|
Proximity Settings
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
327
|
Uint8
|
0
|
0
|
1
|
0 – Disable
|
Proximity detection
|
1 – Enable
|
1116
|
Uint8
|
0
|
0
|
255
|
-
|
Proximity Group ID
|
328
|
Uint8
|
-60
|
-100
|
0
|
dBm
|
Proximity RSSI
|
331
|
Uint8
|
0
|
0
|
20
|
-
|
Proximity RSSI exit threshold
|
332
|
Uint8
|
0
|
0
|
1
|
0 – Disable
|
Proximity RSSI moving average enable
|
1 – Enable
|
333
|
Uint8
|
5
|
0
|
60
|
-
|
Proximity RSSI moving average samples
|
330
|
Uint8
|
1
|
0
|
1
|
0 – Disable
|
Proximity while charging
|
1 – Enable
|
7471
|
Uint16
|
""
|
0
|
10
|
Predefined Number
|
Send SMS to
|
8471
|
String
|
Proximity
|
0
|
160
|
Char
|
SMS Text
|
Lockdown Indication Settings
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
323
|
Uint8
|
30
|
0
|
65500
|
Seconds
|
Pre-Alarm
|
Last Known Position
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
51720
|
Uint8
|
0
|
0
|
1
|
0 – Disable
|
Scenario Settings
|
1 – Enable
|
Tamper detection bracelet
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
321
|
Uint8
|
0
|
0
|
1
|
0 – Disable
|
Tamper Detection
|
1 – Enable
|
320
|
Uint16
|
""
|
0
|
10
|
Predefined Number
|
Call to
|
7475
|
Uint16
|
""
|
0
|
10
|
Predefined Number
|
Send SMS to
|
8475
|
String
|
Tamper
|
0
|
160
|
Char
|
SMS Text
|