Advanced Pulse Counter

From Wiki Knowledge Base | Teltonika GPS

Functionality description

This functionality was added in 03.28.04.Rev.00 firmware version.

If this function is active, then all other settings associated with the this input are disabled.

Frequency measurement can be performed in 2 different ways:

  1. Frequency is measured by counting pulses over time period (997 ms). Method is used for frequencies higher than 100 Hz.
  2. Frequency is measured by measuring time between pulses. Method is used for frequencies lower than 100 Hz.

When 2kHz pulse counter is enabled, all other scenarios will ignore corresponding DIN state, except DIN1 which can be used to wakeup device from Deep Sleep.

Parameter values

System parameters (ID = 145).  Device/Available/Input port/Frequency:

Device Not available DIN1 DIN2 DIN4
50Hz 2kHz 50Hz 2kHz 50Hz 2kHz
FM3001, FM3010 +
FM4001 +
FMB0 [1-6] - FMB010, FMB001, FMB001 buzzer, FMB003, FMB002, FMB020 +
FMC0 [1, 3-4] – FMC001, FMC003. FMC00A +
FMM0 [1, 21-22, 34, 41] – FMM001 BG96, FMM001/3 BG95M3, FMM003 BG95M6, FMM00A BG95M1 +
FMB1 [3-4, 23-24] – FMB125 DualSIM, FMB125 no BAT dualSIM, FMB125, FMB125 no BAT +
[1-2, 5-6, 21-22]1 + +
FMC1 FMC120, FMC122, FMC125, FMC130 +
FMC120, FMC122, FMC130 +
FMU1 [1-5] - FMU120, FMU122, FMU125, FMU130, FMU126,

[23, 24]

+
FMU120, FMU122, FMU130,

[24]

+
FMM1 [3, 23] – FMM125 BG96, FMM125 BG95M3 +
[4, 24-25] – FMM130 BG96, FMM130 BG95M3, FMM13A +
FMB2 [130, 161] – FMB225, FMB225 DualSIM +
[1-3, 132-133] – FMB202, FMB204, FMB206, FMB230, FMB240 + +
FMB208,

[11-14]

+
FMC2 [130] – FMC225 +
[131] – FMC130 +
FMM2 [151] – FMM230 BG95M3 +
FMB9 [1-2(21-22)] – FMB900, FMB920

[3-5] - FMB962, FMB964

FMB964 DualSim, [8-11] - FMB965, FMB965 I/O, FMB930, FMB939,

+
[7] - FMB910 +
FMC9 [1] – FMC920 +
FMM9 [1] – FMM920 +
MCX2 MCX201 + +
MTB1 MTB100 Storageless,

MTB100,

[3]

+

Advanced pulse counter parameter in configurator

Advanced pulse counter.png