EYE FUNCTIONALITIES
Page Description
This page will describe EYE device functionalities, their value flow and required firmware and software versions,
EYE APP 1.2.2-89
Search device with QR scan
Now you can find devices with QR scan by pressing scan button and scanning device QR code.
Customized Sensor Selection
Users can customize their device by selecting only the sensors they require. This allows users to specify which sensor information is read and advertised, ensuring power-efficient data collection and transmission.
Auto-Disconnect Timer
To enhance user privacy and save energy, we've introduced an auto-disconnect feature. After 2 minutes of inactivity, users will be automatically disconnected from the device. Before disconnection, you will have the option to maintain the connection.
Visible battery voltage
Eye App now provides a clear and convenient readout of the battery's voltage level, keeping users informed about their device's power status.
12 characters name
Users can now assign names of up to 12 characters, enabling them to configure their device with a full MAC address as the name.
Functionalities
Connecting to the device
SW version requirements | EYE APP: 1.2.0-60+
Firmware: 1.2.1.R.0 to 1.2.8.R.2 | ||||
---|---|---|---|---|---|
Step No. | 1 | 2 | 3 | 4 | |
Short step desc. | Tap the selected device to connect to it | Wait for connection | Enter PIN | Successfully connected | |
Successful attempt at functionality visual | |||||
Short step desc. | Tap the selected device to connect to it | Enter PIN incorrectly | Fail to enter PIN correctly 4 more times | Wait for 5 min timeout and enter PIN incorrectly | Fail to enter PIN correctly 4 more times |
Additional desc. | Device is locked for 5 min but will allow to connect with PIN again after timeout | Device is locked for 5 min but will allow to connect with PIN again after timeout, thus this is continued in infinite loop. | |||
Failed attempt at functionality visual |
SW version requirements | EYE APP: 1.2.0-60+
Firmware: 1.2.9.R.8+ | ||||
---|---|---|---|---|---|
Short step desc. | Tap the selected device to connect to it | Enter PIN incorrectly | Fail to enter PIN correctly 4 more times | Wait for 5 min timeout and enter PIN incorrectly | Fail to enter PIN correctly 4 more times |
Additional desc. | Device is locked for 5 min but will allow to connect with PIN again after timeout | Device is locked with PUK code now and will remain so until correct PUK is entered, see PUK code unlock. | |||
Failed attempt at functionality visual |
PUK code unlock
SW version requirements | EYE APP: 1.2.0-60+
Firmware: 1.2.9.R.8+ | ||||
---|---|---|---|---|---|
Step No. | |||||
Short step desc. | Tap the blocked device to connect to it | Enter PUK | Connected | ||
Additional desc. | PIN automatically resets to default | ||||
Successful attempt at functionality visual | |||||
Step desc. | Tap the selected device to connect to it | Enter PUK incorrectly | Fail to enter PIN correctly 4 more times | ||
Additional desc. | PUK is rejected and you can only go back or enter correct PUK | ||||
Failed attempt at functionality visual |
Hibernate mode:
Wake up:
SW version requirements | Firmware: 1.2.9.R.8+ | ||||
---|---|---|---|---|---|
Step No. | 1-3 | 4 | |||
Short step desc. | Attach magnet to sleeping device and wait for LED to blink. | Device starts broacasting | |||
Additional desc. | Now device is discoverabled, scannable, connectable via BLE. | ||||
Successful attempt at functionality visual |
Send to sleep:
SW version requirements | EYE APP: 1.2.0-60+
Firmware: 1.2.9.R.8+ | ||
---|---|---|---|
Step No. | 1 | 2 | 3 |
Short step desc. | While connected and in overview tap "Send device to sleep" | Confirm your selection | Wait for EYE App to disconnect |
Additional desc. | Device is no longer connectable or findable until wake up step is performed. | ||
Successful attempt at functionality visual |