Template:FMB Device Family Features Parameter list

From Wiki Knowledge Base | Teltonika GPS
Revision as of 10:47, 19 January 2024 by Jonas Lukauskas (talk | contribs)

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)

Green driving parameters

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11000 Uint8 0 0 3 0 – Disable Scenario settings
1 – Low priority
2 – High priority
3 – Panic priority
11004 Uint8 2.5 0.5 10 m/s2 Max acceleration
11005 Uint8 2.7 0.5 10 m/s2 Max braking
11006 Uint8 3.4 0.5 10 m/s2 Max cornering
11007 Uint8 0 0 1 0 – GPS Source
1 – Accelerometer
11008 uint8 0 0 1 Enable/Disable Duration
11003 Uint8 0 0 2 (1 for FMB125) 0 – None Output control
1 – DOUT 1
2 – DOUT 2
11001 Int32 200 100 5000 Milliseconds DOUT ON duration
11002 Int32 200 0 5000 Milliseconds DOUT OFF duration
7034 Uint8 0 0 10 Phone number Send SMS to
8034 String "Green Driving" 0 160 Text Sms text

Overspeeding scenario parameters


Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11100 Uint8 0 0 3 0 – Disable Scenario settings
1 – Low priority
2 – High priority
3 – Panic priority
11104 Uint16 90 0 260 km/h Max speed
11103 Uint8 0 0 2 (1 for FMB125) 0 – None Output control
1 – DOUT 1
2 – DOUT 2
11101 Int32 200 100 5000 Milliseconds DOUT ON duration
11102 Int32 200 0 5000 Milliseconds DOUT OFF duration
7032 Uint8 0 0 10 Phone number Send SMS to
8032 String "Overspeeding" 0 160 Text Sms text

Jamming scenario parameters


Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11300 Uint8 0 0 3 0 – Disable Scenario settings
1 – Low priority
2 – High priority
3 – Panic priority
11303 Uint8 1 0 1 0 – Disable Eventual records
1 – Enable
11304 Uint8 0 0 2 (1 for FMB125) 0 – None Output control
1 – DOUT1
2 – DOUT2
11301 Int32 200 100 5000 Milliseconds DOUT ON duration
11302 Int32 200 0 5000 Milliseconds DOUT OFF duration
11305 Uint16 60 0 65535 Seconds Timeout

Immobilizer scenario parameters


Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11700 Uint8 0 0 3 0 – Disable Scenario settings
1 – Low priority
2 – High priority
3 – Panic priority
11701 Uint8 1 0 1 0 – Disable Eventual records
1 – Enable
11702 Uint8 0 0 2 (1 for FMB125) 0 - Disable Output control
1 - Enable (DOUT 1)
2 - Enable (DOUT 2)
11703 Uint8 0 0 1 0 - Disable iButton list check
1 - Enable
7140 Uint8 0 0 10 Phone number Send SMS to
8140 String "Immobilizer" 0 160 Text Sms text
60068 Uint16 30 1 65535 Seconds Ignition Off timeout
60076 Uint8 0 0 1 0 – Disable Alcotester Check
1 – Enable
60077 Double 0.4 0 4 BAC Threshold
11708 Uint8 1 0 1 0 – Disable Blood Alcohol Content Event
1 – Enable
7268 Uint8 0 0 10 Phone number Send SMS to
8268 String "Blood" Alcohol Content" 0 160 Text Sms text


DOUT control via call scenario parameters


Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
12000 Uint8 0 0 2 (1 for FMB125) 0 – None Digital Output control
1 – DOUT 1
2 – DOUT 2
12001 Uint8 0 0 3 (1 for FMB125) 0 – None DOUT deactivation
1 – DIN 1
2 – DIN 2
3 – DIN 3
12002 Int32 5 0 2147483647 Seconds Duration timeout

DOUT 1 Output type

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
60067 Uint8 0 0 1 0 - Normal Digital Output control
1 - Inverted

iButton read notification

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11704 Uint8_t 0 0 3 0 - Disabled Digital Output control
1 - DOUT 1
2 – DOUT 2 (FMB120)
3 – DOUT 3 (only for FMB130)
11705 Uint16_t 200 100 50000 Milliseconds DOUT duration
11706 Uint8_t 0 0 1 0 - Disabled iButton notification list
1 - Enabled
11707 Uint8_t 0 0 1 0 - Disabled Depend on ignition
1 - Enabled