Introduction

Wireless solutions open up new horizons for your business and help to keep an eye on your assets. Discover our brand-new and certified Bluetooth® Low Energy ID sensor model from Teltonika with robust waterproof casing and a long-lifetime battery. The model is designed for a low-cost fast and easy configuration and integration to save precious time, resources, and ensure accountability.

BTSMP1-datasheet-2023-12-18.2.png

About BTSMP1

Perfect for traceability use cases, delivery tracking, monitoring of various movable objects in logistics (trailers, containers), agriculture (tractor attachments), and constructions (tools and inventory). Sensors data makes it especially suitable for cold chain refrigerator use cases. The built-in accelerometer can detect item movement, pitch and roll of the device. Magnet detection can be used for wireless open/close detection and notifications such as trailer door events, etc. EYE sensor supports iBeacon and Eddystone protocols. The device is fully compatible with the Teltonika firmware platform which provides extended functionality. Configure, scan, and update anytime anywhere with a dedicated Teltonika mobile app

Product Specification

Features

Functionalities
Beacon ID, LED, Temperature, Humidity, Accelerometer, Magnet detection
Dimensions and weight
Dimensions 56,6 mm x 38 mm x 13 mm
Weight 18g
Battery and power
Model CR2450
Type Type Lithium, Manganese Dioxide
Total Capacity 600 mAh
Replaceable No
Battery life (Tx=2 dBm; interval: 3 s) 2.5+ years
Battery life (Tx=2 dBm; interval: 5 s), default 4+ years
Battery life (Tx=2 dBm; interval: 10 s) 5+ years
Connectivity
Bluetooth® Bluetooth® 4.2 compliant,

Bluetooth® 5.2 certified

Range 80 m
Available transmission power levels Up to 8 dBm
Sensitivity -88 dBm
Casing
Protection IP67
Mounting Two holes to screw/leash/strip, tape
Customization Custom logo upon request (Special conditions)
Environmental Requirements
Humidity (non-condensing) From 0% to 100%
Operational temperature -20°C / +60°C (-4°F / +140°F)
Protocols compatibility
iBeacon Yes

*iOS doesn't show devices with iBeacon protocol

Eddystone Yes
EYE Sensor Yes

Dimensions

Eye dimensions.png

Value-adding Features

Hibernate mode

Hibernated mode means that the EYE device is OFF when shipping from the factory, preserving battery life. PLEASE NOTE that EYE devices are available in two modes: factory-activated (ON) or Hibernated (OFF). You may order the device version which better suits your needs. Order codes are described on eye page

Value of hibernate mode

Hibernated versions of EYE devices simplify stock management for our partners while maximizing battery life.
1. Accelerated delivery times:

By stocking up on hibernated EYE devices, you ensure readiness to deploy EYE devices with full battery capacity at any moment. This proactive approach provides fastest possible service, increases your reputation for efficiency and positions you as an industry frontrunner, enhancing your competitive edge.

2. Mitigated project risks:

In scenarios where projects encounter unforeseen challenges, our hibernated EYE devices offer a buffer. Hibernate feature allows to safeguard your investments and potential revenue streams. This means that even if projects encounter delays or complications, you can still deploy EYE devices with full battery capacity, ensuring optimal performance when the time is right.

How to activate hibernated eye device?

Attach any magnet to sleeping device and wait for LED to blink.
NOTE: ANY MAGNET CAN BE USED
520746 Magnet EYE gif v1.6-min.gif
Now device is discoverable, scannable, connectable via BLE.

How to send the device to hibernate mode?

If you want to put the EYE device back to hibernate mode after accidental activation or simply pause its use, you may do that following steps below:
Step 1. While connected and in overview tap "Send device to sleep":
Step 2. Confirm your selection:
Step 3. Wait for EYE App to disconnect:
Device screen 1.2.8 2.jpgScreenshot 20230509 173323 EYE APP.jpgScreenshot 20230512 164509 Gallery.jpg

Can All devices hibernate?

1. All EYE Sensors with firmware version starting from 1.2.9.R.8 can hibernate.

2. Only new EYE Beacons bought with order codes that have hardware modification can hibernate standard codes are available in eye page, for special order codes consult your sales manager.

Mounting recomendations

Neweyemouning.png
New mounting recomendations 1.png

EYE App Configuration

Devices work constantly and are ready to perform out of the box. Default basic Sensor settings are set to:
• Transmitting at 2 dBm power.
• Data advertising at 1 second intervals.
• Eddystone and Sensors protocol

If you would like to change these settings you will need to:
1) Download and install EYE APP - Teltonika application to change sensor settings.
QR.jpg

Eye App Overview

With the application you will be able to scan for visible Teltonika EYE devices, check their statuses or connect for configuration or firmware update.

1.1.jpg 2.1.jpg Correct1.1.png 4.1.jpg

Devices in view

In this window you will see all visible devices. You have options to see devices in Short list Shortlist.jpg or in default list. When looking at devices in default list you will be able to open Detailed view Detailed.jpg of devices and check transmitted data statuses. Additionaly if you are looking for specific devices you will be able to use Search Search button eye app.jpg function to filter search options. When in this window select a device of your choice to connect and after passing pin code (default pin code is 123456) you will go to device overview window.

Overview window

In overview window you can see device details, check firmware version and update if available, go to device configuration settings and download the configuration. If you select to Configure device new window will open with Basic and Advanced settings. Other actions include changing the device PIN code and putting the device to sleep. A device in sleep mode will no longer be findable or connectable via the app. To wake it up, you need to attach a magnet and look for a green LED flashing.


Configure window

In this window you can check and change device configuration settings. In main tab Basic Settings you can change main settings. Change Device name, Power signal strength, Advertising interval and Packet transmission type*. For more settings go to Advanced settings tab to enable various events.

Advanced configuration window

Advanced configuration: Beacon Settings

IBeacon ID settings.png Eddystone ID settings.png

In Advanced settings tab you can can configure EYE beacon sensor parameters: Beacon information (iBeacon ID*, Eddystone ID). UUID/MINOR/MAJOR parameter can be changed for iBeacon ID*. Namespace ID/Instance ID can be changed for Eddystone ID. If you scroll down you will be able to adjust Sensor reading interval and event settings of the EYE Sensor Note: iOS doesn't show devices with iBeacon protocol

Advanced configuration: Sensor reading and events

!NOTE: These settings are no longer available after EYE APP 1.2.0-60 update.
Magnetic field event.png Humidity event.png Temperature event.png Movement event2.png
Magnetic field event - adjust if the device generates events based on detection or exit (loss) of the magnet. Humidity event - adjust if the device generates events based on entrance or exit to selected humidity range Temperature event - adjust if the device generates events based on entrance or exit to selected temperature range Movement event - adjust movement/stop detection and timeouts it takes to register movement / stopping
Maximum event duration.png Event Advertising settings.png Sensor reading interval.png
Maximum event duration - how long will one event be advertised Event advertising settings - advertising period after event detection Sensor reading interval - how often values are updated by the device