Changes

7 bytes added ,  14:06, 27 March 2023
m
Changed Codec 8 Extended Event I/O value from EF to 0x00EF and 0 to 0x0000
Line 1,057: Line 1,057:  
| style="vertical-align: middle; text-align: center;" |2 bytes
 
| style="vertical-align: middle; text-align: center;" |2 bytes
 
| rowspan="33" style=" width:5%; vertical-align: middle; text-align: left;" |
 
| rowspan="33" style=" width:5%; vertical-align: middle; text-align: left;" |
| rowspan="33" style=" width:65%; vertical-align: middle; text-align: left;" |'''Event IO ID''' – if data is acquired on event – this field defines which IO property has changed and generated an event. For example, when if Ignition state changed and it generate event, Event IO ID will be 0xEF (AVL ID: 239). If it’s not eventual record – the value is 0. <br>
+
| rowspan="33" style=" width:65%; vertical-align: middle; text-align: left;" |'''Event IO ID''' – if data is acquired on event – this field defines which IO property has changed and generated an event. For example, when if Ignition state changed and it generate event, Event IO ID will be 0x00EF (AVL ID: 239). If it’s not eventual record – the value is 0x0000. <br>
 
'''N''' – a total number of properties coming with record (N = N1 + N2 + N4 + N8). <br>
 
'''N''' – a total number of properties coming with record (N = N1 + N2 + N4 + N8). <br>
 
'''N1''' – number of properties, which length is 1 byte. <br>
 
'''N1''' – number of properties, which length is 1 byte. <br>

Navigation menu