ECAN01 TOP.png
ECAN01 BOTTOM.png

ECAN01 (Easy-CAN) is contactless adapter used to read vehicle CAN Bus data. ECAN01 (Easy-CAN) adapter should be used in combination with:

It reads can bus data through the isolation of wires without damaging them and forwards signals to tracking device.

Features

  • Easy-CAN collects vehicle data from CAN bus without damaging the wires
  • Powered from on-board power source
  • Reads the signals through the isolation of CAN bus wires
  • Easy to install and operate

Technical features

PARAMETER VALUE
Minimum Typical Maximum Unit
Supply Voltage
Supply Voltage (Recommended Operating Conditions) +10 +12 +30 V
Current Consumption
Working Mode 6.9 mA
Sleep Mode 1.2 mA
Operating Temperature
Operating Temperature -25 +85 °C
Protection
Internal resettable fuse (max 33 V) 750 mA
  • Dimensions 39.8 x 18 x 16.7 mm
  • CAN-BUS speeds up to 1000 kb/s

Pinout

PIN NUMBER PIN NAME

DESCRIPTION

1 CAN L (Blue) Connect to CAN L input of CAN BUS converter
2 CAN H (White/Blue) Connect to CAN H input of CAN BUS converter
3 VCC (RED) Power supply (10-30) V DC (+)
4 GND (-) (Black) Ground wire (10-30) V DC (-)
ECAN01 pinout.png

Wiring scheme

ECAN01 wiring scheme.png