Changes

m
Text replacement - "Bluetooth" to "Bluetooth®"
Line 2: Line 2:  
| product_name  = FMB125 tracking device
 
| product_name  = FMB125 tracking device
 
}}
 
}}
 +
 +
== 2023.03.01: GNSS antenna changes ==
 +
We would like to update you regarding the changes in GNSS antenna for FMB125, which will now take effect in March 2023. From March 2023 to August 2023, the latest version of GNSS antennas will be provided, and after August 2023, the older version of antennas will be supplied.
 +
{| class="wikitable"
 +
! colspan="3" style="text-align: left; background: white;" |Change description
 +
|-
 +
| style="text-align: left; background: white;" |Change type
 +
| colspan="2" style="text-align: left; background: white;" |Internal
 +
|-
 +
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |Mechanical part changes
 +
|-
 +
| style="text-align: left; background: white;" |Old version:
 +
 +
[[File:2023.03.01- GNSS antenna changes old.png|frameless|397x397px]]
 +
 +
Dimensions - 46x44x13 mm
 +
 +
Center frequency - 1575.42 MHz, 1602 MHz Bandwidth - 35 MHz
 +
 +
VSWR on bandwidth - <1.9
 +
 +
GAIN - 3 dB
 +
 +
LNA minimum gain - 26.5 dB
 +
 +
LNA maximum gain - 29.5 dB
 +
Consumption - 9 mA
 +
| style="text-align: left; background: white;" |New version:
 +
 +
[[File:2023.03.01- GNSS antenna changes new.png|frameless|414x414px]]
 +
 +
Dimensions - 45.2x35.8x15.1 mm
 +
 +
Center frequency - 1575.42 MHz, 1602 MHz Bandwidth - 10 MHz
 +
 +
VSWR on bandwidth - <1.5
 +
 +
GAIN - 2 dB
 +
 +
LNA minimum gain - 26 dB
 +
 +
LNA maximum gain - 30 dB
 +
 +
Consumption - 11 mA
 +
|-
 +
| style="text-align: left; background: white;" |Change reasons
 +
| colspan="2" style="text-align: left; background: white;" |Reaction to antenna market volatility.
 +
 +
|-
 +
|-
 +
| style="text-align: left; background: white;" |Product release date
 +
| colspan="2" style="text-align: left; background: white;" |March, 2023
 +
|}
 +
{| class="wikitable"
 +
! colspan="3" style="text-align: left; background: white;" |Affected products
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Model
 +
| style="width: 448px; text-align: left; background: white;" |Affected order codes
 +
| style="width: 448px; text-align: left; background: white;" |Order code changes
 +
|-
 +
| style="text-align: left; background: white;" |FMB125
 +
| style="text-align: left; background: white;" |FMB125*******order codes
 +
| style="text-align: left; background: white;" |No changes
 +
|}
 +
 +
{| class="wikitable"
 +
! colspan="3" style="text-align: left; background: white;" |Change impact
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Risk assessment
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |Up until August 2023, the latest model of GNSS antennas will be provided, after which point the older version of antennas will be supplied.
 +
|-
 +
| style="text-align: left; background: white;" |Suggested implementation plan
 +
| colspan="2" style="text-align: left; background: white;" |No implementation plan needed.
 +
|}
 +
 +
==2023.02.02: Changes in side frame for the battery placement==
 +
 +
We would like to inform you that the side frame for the battery placement is included, helping to determine the exact location of the battery. Also, minor design changes are made to improve both case production and case assembly. These changes affect FMB110, FMB120, FMB122, FMB125, FMC125, FMM125, FMB130, FMC130, FMM130, FMB140, FMB150, FMC150, and FMM150 devices. The updates in the factory are being implemented in February, 2023.
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change description
 +
|-
 +
| style="text-align: left; background: white;" |Change type
 +
| colspan="2" style="text-align: left; background: white;" |Internal
 +
|-
 +
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |The side frame for the battery placement is included, helping to determine the exact location of the battery. Also, minor design changes are made to improve both case production and case assembly. These changes affect FMB110, FMB120, FMB122, FMB125, FMC125, FMM125, FMB130, FMC130, FMM130, FMB140, FMB150, FMC150, and FMM150 devices.
 +
|-
 +
| style="text-align: left; background: white;" |Old Version: [[File:Old 1.png|center|250px]] [[File:Old 2.png|center|250px]] [[File:Old 3.png|center|250px]]
 +
| style="text-align: left; background: white;" |New Version: [[File:New 1.png|center|250px]] [[File:New 2.png|center|250px]] [[File:New 3.png|center|250px]]
 +
|-
 +
| style="text-align: left; background: white;" |Change reasons
 +
| colspan="2" style="text-align: left; background: white;" |The battery placement is improved with a side frame, helping to determine the exact location of the battery. Minor design changes are made for case production and case assembly. These changes affect FMB110, FMB120, FMB122, FMB125, FMC125, FMM125, FMB130, FMC130, FMM130, FMB140, FMB150, FMC150, and FMM150 devices.
 +
 +
|-
 +
|-
 +
| style="text-align: left; background: white;" |Product release date
 +
| colspan="2" style="text-align: left; background: white;" |February, 2023
 +
|-
 +
|}
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Affected products
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Model
 +
| style="width: 448px; text-align: left; background: white;" |Affected order codes
 +
| style="width: 448px; text-align: left; background: white;" |Order code changes
 +
|-
 +
| style="text-align: left; background: white;" |FMB110, FMB120, FMB122, FMB125, FMC125, FMM125, FMB130, FMC130, FMM130, FMB140, FMB150, FMC150, FMM150
 +
| style="text-align: left; background: white;" |FMB110, FMB120, FMB122, FMB125, FMC125, FMM125, FMB130, FMC130, FMM130, FMB140, FMB150, FMC150, FMM150 all codes
 +
| style="text-align: left; background: white;" |Updated the battery placement with the side frame as well as minor design changes for case production and assembly
 +
|-
 +
|}
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change impact
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Risk assessment
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |During the transition period clients might receive devices with old case design used in manufacture
 +
|-
 +
| style="text-align: left; background: white;" |Suggested implementation plan
 +
| colspan="2" style="text-align: left; background: white;" |Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process.
 +
|-
 +
|}
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="width: 1141px; text-align: left; background: white;" |Acknowledgement of PCN receipt
 +
|-
 +
| colspan="3" style="text-align: left; background: white;" |If no feedback is received within two weeks after the issue date of this notification – Teltonika may accept that this change has tactically accepted and can implement the change as indicated above.
 +
|-
 +
|}
 +
 +
== 2023.01.01: SMA soldering changes ==
 +
We would like to inform you that Antenna connectors (SMA SMD type) in FMB125 devices will be soldered from both sides of PCB starting from January 2023.
 +
{| class="wikitable"
 +
! colspan="3" style="text-align: left; background: white;" |Change description
 +
|-
 +
| style="text-align: left; background: white;" |Change type
 +
| colspan="2" style="text-align: left; background: white;" |Internal
 +
|-
 +
|Detailed description
 +
| style="text-align: left; background: white;" |Old version:
 +
[[File:2023.01.01- SMA soldering changes (FMB125).png|frameless]]
 +
 +
| style="text-align: left; background: white;" |New version:
 +
[[File:2023.01.01- SMA soldering changes (FMB125) new.png|frameless]]
 +
|-
 +
| style="text-align: left; background: white;" |Change reasons
 +
| colspan="2" style="text-align: left; background: white;" |In order to increase the structural rigidity and unify the manufacturing process of Teltonika IoT Group devices, SMA connector will be soldered on the top side of PCB (same as before) and on the bottom side of PCB (performed additionally).
 +
 +
|-
 +
|-
 +
| style="text-align: left; background: white;" |Product release date
 +
| colspan="2" style="text-align: left; background: white;" |January, 2023
 +
|}
 +
{| class="wikitable"
 +
! colspan="3" style="text-align: left; background: white;" |Affected products
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Model
 +
| style="width: 448px; text-align: left; background: white;" |Affected order codes
 +
| style="width: 448px; text-align: left; background: white;" |Order code changes
 +
|-
 +
| style="text-align: left; background: white;" |FMB125
 +
| style="text-align: left; background: white;" |FMB125*******
 +
| style="text-align: left; background: white;" |SMA soldering changes
 +
|}
 +
 +
{| class="wikitable"
 +
! colspan="3" style="text-align: left; background: white;" |Change impact
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Risk assessment
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |Due to THT assembly process, some devices might have an excess amount of soldering on the SMA connector. This does not affect GSM/GNSS antenna characteristics and does not interfere with device case assembly, therefore, device functionality remains unchanged.
 +
 +
[[File:2023.01.01- SMA soldering changes Risk assessment image.png|frameless|375x375px]]
 +
|-
 +
| style="text-align: left; background: white;" |Suggested implementation plan
 +
| colspan="2" style="text-align: left; background: white;" |No implementation plan needed
 +
|}
 +
 +
{| class="wikitable"
 +
! colspan="3" style="width: 1141px; text-align: left; background: white;" |Acknowledgement of PCN receipt
 +
|-
 +
| style="text-align: left; background: white;" |If no feedback is received within  two weeks after the issue date of this notification - Teltonika may accept  that this change has been tacitly accepted and can implement the change as  indicated above.
 +
|
 +
|
 +
|}
 +
==2022.08.01: Base firmware update==
 +
We would like to inform you about the base firmware update for FMB125 starting from August 1st, 2022. New production firmware version will be 03.27.13.Rev.03
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change description
 +
|-
 +
| style="text-align: left; background: white;" |Change type
 +
| colspan="2" style="text-align: left; background: white;" |Firmware update
 +
|-
 +
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMB125_firmware_errata
 +
|-
 +
| style="text-align: left; background: white;" |Old version: <br> FMB125 03.27.07.Rev.00
 +
| style="text-align: left; background: white;" |New version: <br> FMB125 03.27.13.Rev.03
 +
|-
 +
| style="text-align: left; background: white;" |Change reasons
 +
| colspan="2" style="text-align: left; background: white;" |FMB125 base firmware version update
 +
|-
 +
| style="text-align: left; background: white;" | Product release date
 +
| colspan="2" style="text-align: left; background: white;" |2022 August
 +
|-
 +
|}
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Affected products
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Model
 +
| style="width: 448px; text-align: left; background: white;" |Affected order codes
 +
| style="width: 448px; text-align: left; background: white;" | Order code changes
 +
|-
 +
| style="text-align: left; background: white;" |FMB125
 +
| style="text-align: left; background: white;" |FMB125******* order codes with base Firmware
 +
| style="text-align: left; background: white;" |Update firmware
 +
|-
 +
|}
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change impact
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Risk assessment
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture.
 +
|-
 +
| style="text-align: left; background: white;" |Suggested implementation plan
 +
| colspan="2" style="text-align: left; background: white;" | If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager.
 +
|-
 +
|}
    
==2021.08.13: Base firmware update==
 
==2021.08.13: Base firmware update==
Line 92: Line 330:       −
==2021.02.08: Bluetooth Improvement==
+
==2021.02.08: Bluetooth® Improvement==
We would like to inform you, that Bluetooth performance for the FMB125 device will be updated in the factory from March 2021.
+
We would like to inform you, that Bluetooth® performance for the FMB125 device will be updated in the factory from March 2021.
 
{| class="wikitable"
 
{| class="wikitable"
 
! colspan="2" style="text-align: left; background: white;" |Change description
 
! colspan="2" style="text-align: left; background: white;" |Change description
Line 101: Line 339:  
|-
 
|-
 
| style="width: 221px; text-align: left; background: white;" |Detailed description
 
| style="width: 221px; text-align: left; background: white;" |Detailed description
| style="width: 908px; text-align: left; background: white;" |Bluetooth antennas are improved for FMB110, FMB120, FMB122, and FMB125 devices ensuring better signal strength. The efficiency of Bluetooth antennas is considerably increased when receiving or transferring data.
+
| style="width: 908px; text-align: left; background: white;" |Bluetooth® antennas are improved for FMB110, FMB120, FMB122, and FMB125 devices ensuring better signal strength. The efficiency of Bluetooth® antennas is considerably increased when receiving or transferring data.
 
|-
 
|-
 
|Change reasons
 
|Change reasons
| style="text-align: left; background: white;" | Following the changes, the capabilities of our devices will be greatly improved to provide better performance when Bluetooth signal is obstructed or longer distance coverage is required
+
| style="text-align: left; background: white;" | Following the changes, the capabilities of our devices will be greatly improved to provide better performance when Bluetooth® signal is obstructed or longer distance coverage is required
 
|-
 
|-
 
| style="text-align: left; background: white;" |Product release date
 
| style="text-align: left; background: white;" |Product release date

Navigation menu