FMB AVL ID's consist of these parameters groups:

To search for compatible products, Expand all content

Permanent I/O elements


Property ID in AVL packet Property Name Bytes Type Value range Multiplier Units Description HW Support Parameter Group
Min Max
239 Ignition 1 Unsigned 0 1 - -

0 – Ignition Off
1 – Ignition On

Permanent I/O elements
240 Movement 1 Unsigned 0 1 - -

0 – Movement Off
1 – Movement On

Permanent I/O elements
80 Data Mode 1 Unsigned 0 5 - -

0 – Home On Stop
1 – Home On Moving
2 – Roaming On Stop
3 – Roaming On Moving
4 – Unknown On Stop
5 – Unknown On Moving

Permanent I/O elements
21 GSM Signal 1 Unsigned 0 5 - -

Value in range 1-5

Permanent I/O elements
200 Sleep Mode 1 Unsigned 0 4 - -

0 - No Sleep
1 – GPS Sleep
2 – Deep Sleep
3 – Online Sleep
4 - Ultra Sleep

Permanent I/O elements
69 GNSS Status 1 Unsigned 0 3 - -

0 - GNSS OFF
1 – GNSS ON with fix
2 - GNSS ON without fix
3 - GNSS sleep

Permanent I/O elements
181 GNSS PDOP 2 Unsigned 0 500 0.1 m Meters, calculation formula Permanent I/O elements
182 GNSS HDOP 2 Unsigned 0 500 0.1 m Meters, calculation formula Permanent I/O elements
66 External Voltage 2 Unsigned 0 65535 0.001 V

Voltage

Permanent I/O elements
24 Speed 2 Unsigned 0 350 - km/h

Value

Permanent I/O elements
205 GSM Cell ID 2 Unsigned 0 65535 - -

GSM base station ID

Permanent I/O elements
206 GSM Area Code 2 Unsigned 0 65535 - -

Location Area code (LAC), it depends on GSM operator. It provides unique number which assigned to a set of base GSM stations.

Permanent I/O elements
67 Battery Voltage 2 Unsigned 0 65535 0.001 V

Voltage

Permanent I/O elements
68 Battery Current 2 Unsigned 0 65535 0.001 A

Current

Permanent I/O elements
241 Active GSM Operator 4 Unsigned 0 4294967295 - -

Currently used GSM Operator code

Permanent I/O elements
199 Trip Odometer 4 Unsigned 0 2147483647 - m

Trip Odometer value

Permanent I/O elements
16 Total Odometer 4 Unsigned 0 2147483647 - -

Total Odometer value in meters

Permanent I/O elements
1 Digital Input 1 1 Unsigned 0 1 - -

Logic: 0/1

Permanent I/O elements
9 Analog Input 1 2 Unsigned 0 65535 0.001 mV

Voltage

Permanent I/O elements

179 Digital Output 1 1 Unsigned 0 1 - -

Logic: 0/1

Permanent I/O elements
12 Fuel Used GPS 4 Unsigned 0 4294967295 0.001 l

Fuel Used

Permanent I/O elements
13 Fuel Rate GPS 2 Unsigned 0 32767 0.01 l/100km

Average Fuel Use

Permanent I/O elements
17 Axis X 2 Signed -8000 8000 - mG

X axis value

Permanent I/O elements
18 Axis Y 2 Signed -8000 8000 - mG

Y axis value

Permanent I/O elements
19 Axis Z 2 Signed -8000 8000 - mG

Z axis value

Permanent I/O elements
11 ICCID1 8 Unsigned 0 0xffffffffffffffff - -

Value of SIM ICCID, MSB

Permanent I/O elements
10 SD Status 1 Unsigned 0 1 - -

0 - not present 1 - present

Permanent I/O elements
2 Digital Input 2 1 Unsigned 0 1 - -

Logic: 0/1

Permanent I/O elements
3 Digital Input 3 1 Unsigned 0 1 - -

Logic: 0/1

Permanent I/O elements
6 Analog Input 2 2 Unsigned 0 65535 0.001 mV

Voltage

Permanent I/O elements
180 Digital Output 2 1 Unsigned 0 1 - - Logic 0/1 Permanent I/O elements
72 Dallas Temperature 1 4 Signed -550 1150 0.1 °C Degrees ( °C ), -55 - +115,

if 850 – Sensor not ready
if 2000 – Value read error
if 3000 – Not connected
if 4000 – ID failed
if 5000 – same as 850

Permanent I/O elements
73 Dallas Temperature 2 4 Signed -550 1150 0.1 °C Degrees ( °C ), -55 - +115,

if 850 – Sensor not ready
if 2000 – Value read error
if 3000 – Not connected
if 4000 – ID failed
if 5000 – same as 850

Permanent I/O elements
74 Dallas Temperature 3 4 Signed -550 1150 0.1 °C Degrees ( °C ), -55 - +115,

if 850 – Sensor not ready
if 2000 – Value read error
if 3000 – Not connected
if 4000 – ID failed
if 5000 – same as 850

Permanent I/O elements
75 Dallas Temperature 4 4 Signed -550 1150 0.1 °C Degrees ( °C ), -55 - +115,

if 850 – Sensor not ready
if 2000 – Value read error
if 3000 – Not connected
if 4000 – ID failed
if 5000 – same as 850

Permanent I/O elements
76 Dallas Temperature ID 1 8 Unsigned 0 0xffffffffffffffff - - Dallas sensor ID Permanent I/O elements
77 Dallas Temperature ID 2 8 Unsigned 0 0xffffffffffffffff - - Dallas sensor ID Permanent I/O elements
79 Dallas Temperature ID 3 8 Unsigned 0 0xffffffffffffffff - - Dallas sensor ID Permanent I/O elements
71 Dallas Temperature ID 4 8 Unsigned 0 0xffffffffffffffff - - Dallas sensor ID Permanent I/O elements
78 iButton 8 Unsigned 0 0xffffffffffffffff - - iButton ID Permanent I/O elements
207 RFID 8 Unsigned 0 0xffffffffffffffff - - RFID ID

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
201 LLS 1 Fuel Level 2 Signed -4 32767 - kvants or ltr Fuel level measured by LLS sensor via RS232/RS485

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
202 LLS 1 Temperature 1 Signed -128 127 - °C Fuel temperature measured by LLS via RS232/RS485

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
203 LLS 2 Fuel Level 2 Signed -4 32767 - kvants or ltr Fuel level measured by LLS sensor via RS485

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
204 LLS 2 Temperature 1 Signed -128 127 - °C Fuel temperature measured by LLS via RS485

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
210 LLS 3 Fuel Level 2 Unsigned -4 32767 - kvants or ltr Fuel level measured by LLS sensor via RS485

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
211 LLS 3 Temperature 1 Signed -128 127 - °C Fuel temperature measured by LLS via RS485

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
212 LLS 4 Fuel Level 2 Signed -4 32767 - kvants or ltr Fuel level measured by LLS sensor via RS485

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
213 LLS 4 Temperature 1 Signed -128 127 - °C Fuel temperature measured by LLS via RS485

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
214 LLS 5 Fuel Level 2 Signed -4 32767 - kvants or ltr Fuel level measured by LLS sensor via RS485

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
215 LLS 5 Temperature 1 Signed -128 127 - °C Fuel temperature measured by LLS via RS485

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
15 Eco Score 2 Unsigned 0 65535 0.01 - Average amount of events on some distance Permanent I/O elements
113 Battery Level 1 Unsigned 0 100 - % Battery capacity level Permanent I/O elements
238 User ID 8 Unsigned 0 0xffffffffffffffff - - MAC address of NMEA receiver device connected via Bluetooth Permanent I/O elements
237 Network Type 1 Unsigned 0 1 - - 0 - 3G

1 - GSM
2 - 4G
3 - LTE CAT M1
4 - LTE CAT NB1
99 - Unknown

FM3001
FMU125
FMU126
FMU130
FMC125
FMC130
FMC150
FMM125
FMM130
FMM150
FMC001
FMM001
FMC800
FMM800
FMC880
FMM880
FMM80A

Permanent I/O elements
8 Authorized iButton 8 Unsigned 0 0xffffffffffffffff - - If ID is shown in this I/O that means that attached iButton is in iButton List Permanent I/O elements
4 Pulse Counter Din1 4 Unsigned 0 4294967295 - - Counts pulses, count is reset when records are saved Permanent I/O elements
5 Pulse Counter Din2 4 Unsigned 0 4294967295 - - Counts pulses, count is reset when records are saved Permanent I/O elements
263 BT Status 1 Unsigned 0 4 - - 0 - BT is disabled

1 - BT Enabled, not device connected 2 - Device connected, BTv3 Only 3 - Device connected, BLE only 4 - Device connected, BLE + BT

Permanent I/O elements
264 Barcode ID Variable ASCII 0 32 - - Barcode ID Permanent I/O elements
269 Escort LLS Temperature #1 2 Signed -128 127 - °C Fuel temperature

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
270 Escort LLS Fuel level #1 2 Unsigned 0 65535 - - Fuel Level

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
271 Escort LLS Battery Voltage #1 2 Unsigned 0 65535 0.01 V Battery Voltage

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
272 Escort LLS Temperature #2 2 Signed -128 127 - °C Fuel temperature

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
273 Escort LLS Fuel level #2 2 Unsigned 0 65535 - - Fuel Level

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
274 Escort LLS Battery Voltage #2 2 Unsigned 0 65535 0.01 V Battery Voltage

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
275 Escort LLS Temperature #3 2 Signed -128 127 - °C Fuel temperature

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
276 Escort LLS Fuel level #3 2 Unsigned 0 65535 - - Fuel Level

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
277 Escort LLS Battery Voltage #3 2 Unsigned 0 65535 0.01 V Battery Voltage

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
278 Escort LLS Temperature #4 2 Signed -128 127 - °C Fuel temperature

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
279 Escort LLS Fuel level #4 2 Unsigned 0 65535 - - Fuel Level

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
280 Escort LLS Battery Voltage #4 2 Unsigned 0 65535 0.01 V Battery Voltage

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
303 Instant Movement 1 Unsigned 0 1 - - Logic: 0/1 returns movement value Permanent I/O elements
327 UL202-02 Sensor Fuel level 2 Signed -150 32767 0.1 mm UL202-02 Sensor Fuel level

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
483 UL202-02 Sensor Status 1 Unsigned 0 255 - - UL202-02 sensor status codes

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
380 Digital output 3 1 Unsigned 0 1 - - Logic: 0/1

Devices: [Expand] FMB130
FMU130
FMC130
FMC150
FMM130

Permanent I/O elements
381 Ground Sense 1 Unsigned 0 1 - - Logic: 0/1 FMB130

FMU130
FMC130
FMM130
FMB140

Permanent I/O elements
387 ISO6709 Coordinates 34 HEX 0 0x7fffffffffffffff - - ISO6709 Coordinates

Latitude, Longitude (in Degrees, Minutes and Seconds) and Altitude:

IO value format: ±DDMMSS.SSSS±DDDMMSS.SSSS±AAA.AAA/

Permanent I/O elements
636 UMTS/LTE Cell ID 4 Unsigned 0 0xFFFFFFFF - - Permanent I/O elements
403 Driver Name 35 Unsigned - - - - Driver name extracted from card, displayed without delimiters ($ signs)

Devices: [Expand] FMU126


Permanent I/O elements
404 Driver card license type 1 Unsigned 0 8 - -

None - 0
B.1 license type - 1
B.2 license type - 2
B.3 license type - 3
B.4 license type - 4
T.1 license type - 5
T.2 license type - 6
T.3 license type - 7
T.4 license type - 8

Devices: [Expand] FMU126


Permanent I/O elements
405 Driver Gender 1 Unsigned 0 2 - -

None - 0
Male - 1
Female - 2

Devices: [Expand] FMU126


Permanent I/O elements
406 Driver Card ID 4 Unsigned 0 4294967295 - -

None - 0
Male - 1
Female - 2

Devices: [Expand] FMU126


Permanent I/O elements
407 Driver Card Issue Year 1 Unsigned - - - - Value from card as it is

Devices: [Expand] FMU126


Permanent I/O elements
408 Driver Card Issue Year 4 Unsigned 0 4294967295 - - -

Devices: [Expand] FMU126


Permanent I/O elements
409 Driver Status Event 1 Unsigned 0 2 - -

Registered - 0
Deregistered - 1
Swapping - 2

Devices: [Expand] FMU126


Permanent I/O elements




Eventual I/O elements


Property ID in AVL packet Property Name Bytes Type Value range Multiplier Units Description HW Support Parameter Group
Min Max
175 Auto Geofence 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

Eventual I/O elements
250 Trip 1 Unsigned 0 1 - -

0 – trip stop
1 – trip start
From 01.00.24 fw version available with BT app new values:
2 – Business Status
3 – Private Status
4-9 – Custom Statuses

Eventual I/O elements
255 Over Speeding 1 Unsigned 0 255 - km/h

At over speeding start km/h, at over speeding end km/h

Eventual I/O elements
253 Green driving type 1 Unsigned 1 3 - -

1 – harsh acceleration
2 – harsh braking
3 – harsh cornering

Eventual I/O elements
246 Towing 1 Unsigned 0 1 - -

0 – steady
1 – towing

Eventual I/O elements
254 Green Driving Value 1 Unsigned 0 255 acc and braking: 0.01 G or rad Depending on green driving type: if harsh acceleration or braking – g*100 (value 123 -> 1.23g). If Green driving source is „GPS“ – harsh cornering value is rad/s*100. If source is „Accelerometer“ – g*100. Eventual I/O elements