Difference between revisions of "FMB920 Product Change Notifications"

From Wiki Knowledge Base | Teltonika GPS
 
(29 intermediate revisions by 10 users not shown)
Line 1: Line 1:
  {{Template:Pcn_intro_FM
+
{{Template:Pcn_intro_FM
| product_name  = FMB920
+
| product_name  = FMB920 tracking device
 
}}
 
}}
 +
==2023.03.08: TOP and BOT casing changes==
 +
 +
We would like to inform you, TOP and BOT casing part is updated for FMB920, FMB900, FMC920, FMM920 projects starting from 2023 March.
 +
 +
{| class="wikitable" style="width:100%;"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change description
 +
|-
 +
| style="text-align: left; background: white;" |Change type
 +
| colspan="2" style="text-align: left; background: white;" |Internal/visual
 +
|-
 +
| rowspan="2" style="width: 20%; text-align: left; background: white;" |Detailed description
 +
| colspan="2" style="text-align: left; background: white;" |TOP and BOT casing parts inner design updated
 +
|-
 +
| style="width: 40%; text-align: left; background: white;" |TOP part: <br> [[File:FMx920_Top.png|center|400px]]
 +
| style="width: 40%; text-align: left; background: white;" |BOT part: <br />[[File:FMx920_Bot.png|center|400px]]
 +
|-
 +
| style="text-align: left; background: white;" |Changes
 +
| style="width: 40%; text-align: left; background: white;" |TOP casing part
 +
1. Unused legacy holes for holes for screws removed to reduce plastic and complexity </br>
 +
2. PCB end support features optimized to reduce plastic and lower the risk of cosmetic defects on the outside </br>
 +
3. Part number and material type (polycarbonate) now shown on the inside of the casing </br>
 +
4. PCB side support design optimized to improve easy of assembly
 +
| style="width: 40%; text-align: left; background: white;" |BOT casing part
 +
1. Unused legacy holes for holes for screws removed to reduce plastic and complexity </br>
 +
2. PCB end support features optimized to reduce plastic and lower the risk of cosmetic defects on the outside </br>
 +
3. Part number and material type (polycarbonate) now shown on the inside of the casing </br>
 +
4. PCB side support design optimized to improve easy of assembly
 +
|-
 +
| style="text-align: left; background: white;" |Product release date
 +
| colspan="2" style="text-align: left; background: white;" |March 2023
 +
|-
 +
|}
 +
 +
{| class="wikitable" style="width:100%;"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Affected products
 +
|-
 +
| style="width: 20%; text-align: left; background: white;" |Models
 +
| style="width: 40%; text-align: left; background: white;" |Affected order codes
 +
| style="width: 40%; text-align: left; background: white;" |Order code changes
 +
|-
 +
| style="text-align: left; background: white;" |FMB920, FMB900, FMC920, FMM920
 +
| style="text-align: left; background: white;" |All order codes
 +
| style="text-align: left; background: white;" |No changes for the order codes
 +
|-
 +
|}
 +
 +
{| class="wikitable" style="width:100%;"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change impact
 +
|-
 +
| style="width: 20%; text-align: left; background: white;" |Risk assessment
 +
| colspan="2" style="width: 80%; text-align: left; background: white;" |During the transition period clients might receive devices with old type casing.
 +
|-
 +
| style="text-align: left; background: white;" |Suggested implementation plan
 +
| colspan="2" style="text-align: left; background: white;" |No implementation plan needed
 +
|-
 +
|}
 +
 +
{| class="wikitable" style="width:100%;"
 +
|+
 +
! colspan="3" style="width: 100%; text-align: left; background: white;" |Acknowledgement of PCN receipt
 +
|-
 +
| colspan="3" style="text-align: left; background: white;" |If no feedback is received within two weeks after the issue date of this notification - Teltonika Telematics may accept that this change has been tacitly accepted and can implement the change as indicated above
 +
|-
 +
|}
 +
==2022.12.21: Base firmware update and new accelerometer component support==
 +
We would like to inform you about the base firmware update for FMB920 starting from December 21st, 2022. New production firmware version will be 03.27.14.Rev.00
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change description
 +
|-
 +
| style="text-align: left; background: white;" |Change type
 +
| colspan="2" style="text-align: left; background: white;" |Firmware update
 +
|-
 +
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMB920_firmware_errata
 +
|-
 +
| style="text-align: left; background: white;" |Old version: <br> FMB920 03.27.13.Rev.03
 +
| style="text-align: left; background: white;" |New version: <br> FMB920 03.27.14.Rev.00
 +
|-
 +
| style="text-align: left; background: white;" |Change reasons
 +
| colspan="2" style="text-align: left; background: white;" |Assembly optimization to prevent accelerometer compontent shortage in order to ensure stable supply.
 +
Together with assembly update new firmware released to support new accelerometer component.
 +
|-
 +
| style="text-align: left; background: white;" | Product release date
 +
| colspan="2" style="text-align: left; background: white;" |2022 - December Firmware Update with new accelerometer component support</br>
 +
|-
 +
|}
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Affected products
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Model
 +
| style="width: 448px; text-align: left; background: white;" |Affected order codes
 +
| style="width: 448px; text-align: left; background: white;" | Order code changes
 +
|-
 +
| style="text-align: left; background: white;" |FMB920
 +
| style="text-align: left; background: white;" |FMB920******* order codes with base Firmware
 +
| style="text-align: left; background: white;" |Update firmware
 +
|-
 +
|}
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change impact
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Risk assessment
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |During the transition period clients might receive devices with previous Firmware version used in manufacture.
 +
 +
|-
 +
| style="text-align: left; background: white;" |Suggested implementation plan
 +
| colspan="2" style="text-align: left; background: white;" |For further assistance, please contact your Teltonika Telematics sales manager or fill query on HelpDesk.
 +
 +
|-
 +
|}
 +
 +
==2022.08.01: Base firmware update==
 +
We would like to inform you about the base firmware update for FMB920 starting from August 1st, 2022. New production firmware version will be 03.27.13.Rev.03
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change description
 +
|-
 +
| style="text-align: left; background: white;" |Change type
 +
| colspan="2" style="text-align: left; background: white;" |Firmware update
 +
|-
 +
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMB920_firmware_errata
 +
|-
 +
| style="text-align: left; background: white;" |Old version: <br> FMB920 03.27.07.Rev.00
 +
| style="text-align: left; background: white;" |New version: <br> FMB920 03.27.13.Rev.03
 +
|-
 +
| style="text-align: left; background: white;" |Change reasons
 +
| colspan="2" style="text-align: left; background: white;" |FMB920 base firmware version update
 +
|-
 +
| style="text-align: left; background: white;" | Product release date
 +
| colspan="2" style="text-align: left; background: white;" |2022 August
 +
|-
 +
|}
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Affected products
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Model
 +
| style="width: 448px; text-align: left; background: white;" |Affected order codes
 +
| style="width: 448px; text-align: left; background: white;" | Order code changes
 +
|-
 +
| style="text-align: left; background: white;" |FMB920
 +
| style="text-align: left; background: white;" |FMB920******* order codes with base Firmware
 +
| style="text-align: left; background: white;" |Update firmware
 +
|-
 +
|}
 +
 +
==2021.08.13: Base firmware update==
 +
We would like to inform you about the base firmware update for FMB920 starting from August 13th, 2021. New production firmware version will be 03.27.07.Rev.00
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change description
 +
|-
 +
| style="text-align: left; background: white;" |Change type
 +
| colspan="2" style="text-align: left; background: white;" |Firmware update
 +
|-
 +
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMB920_firmware_errata
 +
|-
 +
| style="text-align: left; background: white;" |Old version: <br> FMB920 03.25.18.Rev.08
 +
| style="text-align: left; background: white;" |New version: <br> FMB920 03.27.07.Rev.00
 +
|-
 +
| style="text-align: left; background: white;" |Change reasons
 +
| colspan="2" style="text-align: left; background: white;" |FMB920 base firmware version update
 +
|-
 +
| style="text-align: left; background: white;" | Product release date
 +
| colspan="2" style="text-align: left; background: white;" |2021 August
 +
|-
 +
|}
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Affected products
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Model
 +
| style="width: 448px; text-align: left; background: white;" |Affected order codes
 +
| style="width: 448px; text-align: left; background: white;" | Order code changes
 +
|-
 +
| style="text-align: left; background: white;" |FMB920
 +
| style="text-align: left; background: white;" |FMB920******* order codes with base Firmware
 +
| style="text-align: left; background: white;" |Update firmware
 +
|-
 +
|}
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change impact
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Risk assessment
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture.
 +
|-
 +
| style="text-align: left; background: white;" |Suggested implementation plan
 +
| colspan="2" style="text-align: left; background: white;" | If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager.
 +
|-
 +
|}
 +
 +
==2021.05.17: Base firmware update==
 +
 +
We would like to inform you about the base firmware update for FMB920 starting from May 17th, 2021. New production firmware version will be '''03.25.18.Rev.08'''.
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change description
 +
|-
 +
| style="text-align: left; background: white;" |Change type
 +
| colspan="2" style="text-align: left; background: white;" |Firmware update
 +
|-
 +
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMB920_firmware_errata
 +
|-
 +
| style="text-align: left; background: white;" |Old version: <br> 03.25.18.Rev.05
 +
| style="text-align: left; background: white;" |New version: <br> 03.25.18.Rev.08
 +
|-
 +
| style="text-align: left; background: white;" |Change reasons
 +
| colspan="2" style="text-align: left; background: white;" |FMB920 base firmware version update
 +
|-
 +
| style="text-align: left; background: white;" |Product release date
 +
| colspan="2" style="text-align: left; background: white;" |2021 May.
 +
|-
 +
|}
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Affected products
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Model
 +
| style="width: 448px; text-align: left; background: white;" |Affected order codes
 +
| style="width: 448px; text-align: left; background: white;" |Order code changes
 +
|-
 +
| style="text-align: left; background: white;" |FMB920
 +
| style="text-align: left; background: white;" |FMB920******* order codes with base Firmware
 +
| style="text-align: left; background: white;" |Update firmware
 +
|-
 +
|}
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change impact
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Risk assessment
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically
 +
|-
 +
| style="text-align: left; background: white;" |Suggested implementation plan
 +
| colspan="2" style="text-align: left; background: white;" |If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager.
 +
|-
 +
|}
 +
 +
 +
==2021.03.02: Base firmware update==
 +
 +
We would like to inform you about the base firmware update for FMB920starting from March 03th, 2021. New production firmware version will be '''03.25.18.Rev.05'''.
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change description
 +
|-
 +
| style="text-align: left; background: white;" |Change type
 +
| colspan="2" style="text-align: left; background: white;" |Firmware update
 +
|-
 +
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMB920_firmware_errata
 +
|-
 +
| style="text-align: left; background: white;" |Old version: <br> 03.25.15.Rev.32
 +
| style="text-align: left; background: white;" | New version: <br> 03.25.18.Rev.05
 +
|-
 +
| style="text-align: left; background: white;" |Change reasons
 +
| colspan="2" style="text-align: left; background: white;" |FMB920 base firmware version update
 +
|-
 +
| style="text-align: left; background: white;" |Product release date
 +
| colspan="2" style="text-align: left; background: white;" |2021 March.
 +
|-
 +
|}
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Affected products
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Model
 +
| style="width: 448px; text-align: left; background: white;" |Affected order codes
 +
| style="width: 448px; text-align: left; background: white;" |Order code changes
 +
|-
 +
| style="text-align: left; background: white;" |FMB920
 +
| style="text-align: left; background: white;" |FMB920******* order codes with base Firmware
 +
| style="text-align: left; background: white;" |Update firmware
 +
|-
 +
|}
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change impact
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Risk assessment
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically
 +
|-
 +
| style="text-align: left; background: white;" |Suggested implementation plan
 +
| colspan="2" style="text-align: left; background: white;" |If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager.
 +
|-
 +
|}
 +
 +
==2020.11.01: Top Laser Printing Changes==
 +
 +
We would like to inform you, that laser printing of the FMB920 device was updated in the factory in November 2020.
 +
 +
{| class="wikitable" style="width:100%;"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change description
 +
|-
 +
| style="text-align: left; background: white;" |Change type
 +
| colspan="2" style="text-align: left; background: white;" |External/visual
 +
|-
 +
| rowspan="2" style="width: 20%; text-align: left; background: white;" |Detailed description
 +
| colspan="2" style="text-align: left; background: white;" |Top laser printing design changed
 +
|-
 +
| style="width: 40%; text-align: left; background: white;" |Old version: <br> [[File:FMB920_Top_laser_printing_design_v1.3.png|center|400px]]
 +
| style="width: 40%; text-align: left; background: white;" |New version: <br />[[File:FMB920_Top_laser_printing_design_v1.5.png|center|400px]]
 +
|-
 +
| style="text-align: left; background: white;" |Change reasons
 +
| colspan="2" style="text-align: left; background: white;" |1. Updated Emark certificate number. </br> 2. Added UKCA label. </br> 3. Updated Teltonika brand to Teltonika Telematics.
 +
|-
 +
| style="text-align: left; background: white;" |Product release date
 +
| colspan="2" style="text-align: left; background: white;" |November 2020
 +
|-
 +
|}
 +
 +
{| class="wikitable" style="width:100%;"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Affected products
 +
|-
 +
| style="width: 20%; text-align: left; background: white;" |Model
 +
| style="width: 40%; text-align: left; background: white;" |Affected order codes
 +
| style="width: 40%; text-align: left; background: white;" |Order code changes
 +
|-
 +
| style="text-align: left; background: white;" |FMB920
 +
| style="text-align: left; background: white;" |FMB920*******
 +
| style="text-align: left; background: white;" |New casing
 +
|-
 +
|}
 +
 +
{| class="wikitable" style="width:100%;"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change impact
 +
|-
 +
| style="width: 20%; text-align: left; background: white;" |Risk assessment
 +
| colspan="2" style="width: 80%; text-align: left; background: white;" |No risk factors encountered with this change
 +
|-
 +
| style="text-align: left; background: white;" |Suggested implementation plan
 +
| colspan="2" style="text-align: left; background: white;" |Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process
 +
|-
 +
|}
 +
 +
{| class="wikitable" style="width:100%;"
 +
|+
 +
! colspan="3" style="width: 100%; text-align: left; background: white;" |Acknowledgement of PCN receipt
 +
|-
 +
| colspan="3" style="text-align: left; background: white;" |If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
 +
|-
 +
|}
 +
 +
==2020.01.22: Base firmware update==
 +
 +
We would like to inform you about the base firmware update for FMB920 starting from January 22th, 2020. New production firmware version will be '''03.25.15.Rev.01'''.
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change description
 +
|-
 +
| style="text-align: left; background: white;" |Change type
 +
| colspan="2" style="text-align: left; background: white;" |Firmware update
 +
|-
 +
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMB920_firmware_errata
 +
|-
 +
| style="text-align: left; background: white;" |Old version: <br> FMB920 03.25.05.Rev.00
 +
| style="text-align: left; background: white;" |New version: <br> FMB920 03.25.15.Rev.01
 +
|-
 +
| style="text-align: left; background: white;" |Change reasons
 +
| colspan="2" style="text-align: left; background: white;" |FMB920 base firmware version update
 +
|-
 +
| style="text-align: left; background: white;" |Product release date
 +
| colspan="2" style="text-align: left; background: white;" |2020 January 22th.
 +
|-
 +
|}
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Affected products
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Model
 +
| style="width: 448px; text-align: left; background: white;" |Affected order codes
 +
| style="width: 448px; text-align: left; background: white;" |Order code changes
 +
|-
 +
| style="text-align: left; background: white;" |FMB920
 +
| style="text-align: left; background: white;" |FMB920******* order codes with base Firmware
 +
| style="text-align: left; background: white;" |Update firmware
 +
|-
 +
|}
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change impact
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Risk assessment
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically
 +
|-
 +
| style="text-align: left; background: white;" |Suggested implementation plan
 +
| colspan="2" style="text-align: left; background: white;" |If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager.
 +
|-
 +
|}
 +
 +
==2019.12.02: new FMB920 case design==
 +
 +
Effective December 2019, FMB920 trackers will be shipped with '''new case design'''.
 +
 +
{| class="wikitable" style="width:100%;"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change description
 +
|-
 +
| style="text-align: left; background: white;" |Change type
 +
| colspan="2" style="text-align: left; background: white;" |External/visual
 +
|-
 +
| rowspan="2" style="width: 20%; text-align: left; background: white;" |Detailed description
 +
| colspan="2" style="text-align: left; background: white;" |New design of laser printing. Information provided on module will remain the same
 +
|-
 +
| style="width: 40%; text-align: left; background: white;" |Old version: <br> [[File:FMB920 eng.png|center|400px]]
 +
| style="width: 40%; text-align: left; background: white;" |New version:
 +
 +
 +
<br />[[File:FMB920_4000x4000.png|center|300px]]
 +
 +
 +
<br />
 +
|-
 +
| style="text-align: left; background: white;" |Change reasons
 +
| colspan="2" style="text-align: left; background: white;" |Uniffication of all Teltonika devices markings
 +
|-
 +
| style="text-align: left; background: white;" |Product release date
 +
| colspan="2" style="text-align: left; background: white;" |December 2019
 +
|-
 +
|}
 +
 +
{| class="wikitable" style="width:100%;"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Affected products
 +
|-
 +
| style="width: 20%; text-align: left; background: white;" |Model
 +
| style="width: 40%; text-align: left; background: white;" |Affected order codes
 +
| style="width: 40%; text-align: left; background: white;" |Order code changes
 +
|-
 +
| style="text-align: left; background: white;" |FMB920
 +
| style="text-align: left; background: white;" |FMB920*******
 +
| style="text-align: left; background: white;" |New casing
 +
|-
 +
|}
 +
 +
{| class="wikitable" style="width:100%;"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change impact
 +
|-
 +
| style="width: 20%; text-align: left; background: white;" |Risk assessment
 +
| colspan="2" style="width: 80%; text-align: left; background: white;" |No risk factors encountered with this change
 +
|-
 +
| style="text-align: left; background: white;" |Suggested implementation plan
 +
| colspan="2" style="text-align: left; background: white;" |Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process
 +
|-
 +
|}
 +
 +
{| class="wikitable" style="width:100%;"
 +
|+
 +
! colspan="3" style="width: 100%; text-align: left; background: white;" |Acknowledgement of PCN receipt
 +
|-
 +
| colspan="3" style="text-align: left; background: white;" |If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
 +
|-
 +
|}
  
 
==2019.10.09:  Top Device Marking Changes==
 
==2019.10.09:  Top Device Marking Changes==
  
We would like to inform you, that tampography of FMB920 device was updated to engraving in factory on the 8th of October.  
+
We would like to inform you, that tampography of the FMB920 device was updated to engraving in the factory on the 8th of October.  
  
 
{| class="wikitable"
 
{| class="wikitable"
 
|+
 
|+
! style="text-align: left; background: white;" colspan="3" | Change description
+
! colspan="3" style="text-align: left; background: white;" |Change description
 
|-
 
|-
| style="text-align: left; background: white;" | Change type
+
| style="text-align: left; background: white;" |Change type
| style="text-align: left; background: white;" colspan="2" | External/visual
+
| colspan="2" style="text-align: left; background: white;" |External/visual
 
|-
 
|-
| style="width: 221px; text-align: left; background: white;" rowspan="2" | Detailed description
+
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
| style="width: 908px; text-align: left; background: white;" colspan="2" | Device marking changed from tampography to laser printing. Information provided on module will remain the same  
+
| colspan="2" style="width: 908px; text-align: left; background: white;" |Device marking changed from tampography to laser printing. Information provided on module will remain the same
 
|-
 
|-
| style="text-align: left; background: white;" | Old Version: <br>  [[File:FMB920_600x600_PNG_1.png|center|500px]]
+
| style="text-align: left; background: white;" |Old Version: <br>  [[File:FMB920_600x600_PNG_1.png|center|500px]]
| style="text-align: left; background: white;" | New Version: <br>  [[File:FMB920_eng.png|center|500px]]
+
| style="text-align: left; background: white;" |New Version: <br>  [[File:FMB920_eng.png|center|500px]]
 
|-
 
|-
| style="text-align: left; background: white;" | Change reasons
+
| style="text-align: left; background: white;" |Change reasons
| style="text-align: left; background: white;" colspan="2" | To improve manufacturing speed, efficiency and reliability  
+
| colspan="2" style="text-align: left; background: white;" |To improve manufacturing speed, efficiency and reliability  
 
To increase quality, precision and durability of marking.
 
To increase quality, precision and durability of marking.
  
 
|-
 
|-
 
|-
 
|-
| style="text-align: left; background: white;" | Product release date
+
| style="text-align: left; background: white;" |Product release date
| style="text-align: left; background: white;" colspan="2" | Planned date: 2019 October  
+
| colspan="2" style="text-align: left; background: white;" |Planned date: 2019 October
 
|-
 
|-
 
|}
 
|}
 
{| class="wikitable"
 
{| class="wikitable"
 
|+
 
|+
! style="text-align: left; background: white;" colspan="3" | Affected products
+
! colspan="3" style="text-align: left; background: white;" |Affected products
 
|-
 
|-
| style="width: 221px; text-align: left; background: white;" | Model
+
| style="width: 221px; text-align: left; background: white;" |Model
| style="width: 448px; text-align: left; background: white;" | Affected order codes
+
| style="width: 448px; text-align: left; background: white;" |Affected order codes
| style="width: 448px; text-align: left; background: white;" | Order code changes
+
| style="width: 448px; text-align: left; background: white;" |Order code changes
 
|-
 
|-
| style="text-align: left; background: white;" | FMB920
+
| style="text-align: left; background: white;" |FMB920
| style="text-align: left; background: white;" | FMB920*******
+
| style="text-align: left; background: white;" |FMB920*******
| style="text-align: left; background: white;" | No changes
+
| style="text-align: left; background: white;" |No changes
 
|-
 
|-
 
|}
 
|}
Line 46: Line 528:
 
{| class="wikitable"
 
{| class="wikitable"
 
|+
 
|+
! style="text-align: left; background: white;" colspan="3" | Change impact
+
! colspan="3" style="text-align: left; background: white;" |Change impact
 
|-
 
|-
| style="width: 221px; text-align: left; background: white;" | Risk assessment
+
| style="width: 221px; text-align: left; background: white;" |Risk assessment
| style="width: 908px; text-align: left; background: white;" colspan="2"| No risk factors encountered with this change
+
| colspan="2" style="width: 908px; text-align: left; background: white;" |No risk factors encountered with this change
 
|-
 
|-
| style="text-align: left; background: white;" | Suggested implementation plan
+
| style="text-align: left; background: white;" |Suggested implementation plan
| style="text-align: left; background: white;" colspan="2"| No implementation plan needed
+
| colspan="2" style="text-align: left; background: white;" |No implementation plan needed
 
|-
 
|-
 
|}
 
|}
Line 58: Line 540:
 
{| class="wikitable"
 
{| class="wikitable"
 
|+
 
|+
! style="width: 1141px; text-align: left; background: white;" colspan="3" | Acknowledgement of PCN receipt
+
! colspan="3" style="width: 1141px; text-align: left; background: white;" |Acknowledgement of PCN receipt
 
|-
 
|-
| style="text-align: left; background: white;" colspan="3"| If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
+
| colspan="3" style="text-align: left; background: white;" |If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
 
|-
 
|-
 
|}
 
|}
  
To download the pdf version of this notification, [[Media:PCN_FMB920_20191008_EN.pdf|click here]].
+
To download the pdf version of this notification, [[Media:PCN FMB920 20191008 EN.pdf|click here]].
  
 
==2019.08.14:  Top Tampography Changes==
 
==2019.08.14:  Top Tampography Changes==
  
We would like to inform you, that tampography of FMB920 device was updated in factory on the 5th of August.  
+
We would like to inform you, that tampography of the FMB920 device was updated in the factory on the 5th of August.  
  
 
{| class="wikitable"
 
{| class="wikitable"
 
|+
 
|+
! style="text-align: left; background: white;" colspan="3" | Change description
+
! colspan="3" style="text-align: left; background: white;" |Change description
 
|-
 
|-
| style="text-align: left; background: white;" | Change type
+
| style="text-align: left; background: white;" |Change type
| style="text-align: left; background: white;" colspan="2" | External/visual
+
| colspan="2" style="text-align: left; background: white;" |External/visual
 
|-
 
|-
| style="width: 221px; text-align: left; background: white;" rowspan="2" | Detailed description
+
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
| style="width: 908px; text-align: left; background: white;" colspan="2" | Top tampography design changed  
+
| colspan="2" style="width: 908px; text-align: left; background: white;" |Top tampography design changed
 
|-
 
|-
| style="text-align: left; background: white;" | Old Version: <br>  [[File:FMB920 new.png|center|400px]]
+
| style="text-align: left; background: white;" |Old Version: <br>  [[File:FMB920 new.png|center|400px]]
| style="text-align: left; background: white;" | New Version: <br>  [[File:FMB920 new2.png|center|400px]]
+
| style="text-align: left; background: white;" |New Version: <br>  [[File:FMB920 new2.png|center|400px]]
 
|-
 
|-
| style="text-align: left; background: white;" | Change reasons
+
| style="text-align: left; background: white;" |Change reasons
| style="text-align: left; background: white;" colspan="2" | 1. Updated Emark certificate number.
+
| colspan="2" style="text-align: left; background: white;" |1. Updated Emark certificate number.
 
|-
 
|-
 
|-
 
|-
| style="text-align: left; background: white;" | Product release date
+
| style="text-align: left; background: white;" |Product release date
| style="text-align: left; background: white;" colspan="2" | Updated tampographs will be used from the time when the stock will be sold all leftovers. Planned date: 35 week
+
| colspan="2" style="text-align: left; background: white;" |Updated tampographs will be used from the time when the stock will be sold all leftovers. Planned date: 35 week
 
|-
 
|-
 
|}
 
|}
 
{| class="wikitable"
 
{| class="wikitable"
 
|+
 
|+
! style="text-align: left; background: white;" colspan="3" | Affected products
+
! colspan="3" style="text-align: left; background: white;" |Affected products
 
|-
 
|-
| style="width: 221px; text-align: left; background: white;" | Model
+
| style="width: 221px; text-align: left; background: white;" |Model
| style="width: 448px; text-align: left; background: white;" | Affected order codes
+
| style="width: 448px; text-align: left; background: white;" |Affected order codes
| style="width: 448px; text-align: left; background: white;" | Order code changes
+
| style="width: 448px; text-align: left; background: white;" |Order code changes
 
|-
 
|-
| style="text-align: left; background: white;" | FMB920
+
| style="text-align: left; background: white;" |FMB920
| style="text-align: left; background: white;" | FMB920*******
+
| style="text-align: left; background: white;" |FMB920*******
| style="text-align: left; background: white;" | No changes
+
| style="text-align: left; background: white;" |No changes
 
|-
 
|-
 
|}
 
|}
Line 107: Line 589:
 
{| class="wikitable"
 
{| class="wikitable"
 
|+
 
|+
! style="text-align: left; background: white;" colspan="3" | Change impact
+
! colspan="3" style="text-align: left; background: white;" |Change impact
 
|-
 
|-
| style="width: 221px; text-align: left; background: white;" | Risk assessment
+
| style="width: 221px; text-align: left; background: white;" |Risk assessment
| style="width: 908px; text-align: left; background: white;" colspan="2"| No risk factors encountered with this change
+
| colspan="2" style="width: 908px; text-align: left; background: white;" |No risk factors encountered with this change
 
|-
 
|-
| style="text-align: left; background: white;" | Suggested implementation plan
+
| style="text-align: left; background: white;" |Suggested implementation plan
| style="text-align: left; background: white;" colspan="2"| Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process
+
| colspan="2" style="text-align: left; background: white;" |Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process
 
|-
 
|-
 
|}
 
|}
Line 119: Line 601:
 
{| class="wikitable"
 
{| class="wikitable"
 
|+
 
|+
! style="width: 1141px; text-align: left; background: white;" colspan="3" | Acknowledgement of PCN receipt
+
! colspan="3" style="width: 1141px; text-align: left; background: white;" |Acknowledgement of PCN receipt
 
|-
 
|-
| style="text-align: left; background: white;" colspan="3"| If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
+
| colspan="3" style="text-align: left; background: white;" |If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
 
|-
 
|-
 
|}
 
|}
  
To download the pdf version of this notification, [[Media:PCN_FMB920_20190805_EN.pdf|click here]].
+
To download the pdf version of this notification, [[Media:PCN FMB920 20190805 EN.pdf|click here]].
  
 
==2019.07.22: new no brand Eco friendly boxes==
 
==2019.07.22: new no brand Eco friendly boxes==
  
Effective September 2019, FMB920 trackers with no brand packaging will be shipped with a '''new no brand eco friendly box'''.
+
Effective September 2019, FMB920 trackers with no brand packaging will be shipped with a '''new no brand eco-friendly box'''.
  
 
{| class="wikitable"
 
{| class="wikitable"
 
|+
 
|+
! style="text-align: left; background: white;" colspan="3" | Change description
+
! colspan="3" style="text-align: left; background: white;" |Change description
 
|-
 
|-
| style="text-align: left; background: white;" | Change type
+
| style="text-align: left; background: white;" |Change type
| style="text-align: left; background: white;" colspan="2" | Packaging
+
| colspan="2" style="text-align: left; background: white;" |Packaging
 
|-
 
|-
| style="width: 221px; text-align: left; background: white;" rowspan="3" | Detailed description
+
| rowspan="3" style="width: 221px; text-align: left; background: white;" |Detailed description
| style="width: 908px; text-align: left; background: white;" colspan="2" | Improved and more environmentally friendly packaging box  
+
| colspan="2" style="width: 908px; text-align: left; background: white;" |Improved and more environmentally friendly packaging box
 
|-
 
|-
 
| style="text-align: left; background: white;" |Old single packaging version: <br><br> [[File:Small-white-cut.png|left|365px]] <br> <strong>Dimensions:</strong> 165 (W) x 145 (D) x 35 (H)
 
| style="text-align: left; background: white;" |Old single packaging version: <br><br> [[File:Small-white-cut.png|left|365px]] <br> <strong>Dimensions:</strong> 165 (W) x 145 (D) x 35 (H)
| style="text-align: left; background: white;" | New single packaging version: <br> [[File:Small-eco-cut.png|center|400px]] <br> <strong>Dimensions:</strong> 175 (W) x 150 (D) x 35 (H)
+
| style="text-align: left; background: white;" |New single packaging version: <br> [[File:Small-eco-cut.png|center|400px]] <br> <strong>Dimensions:</strong> 175 (W) x 150 (D) x 35 (H)
 
|-
 
|-
| style="text-align: left; background: white;" | Old group packaging version: <br><br> [[File:Large-white-cut.png|left|400px]] <br> <strong>Dimensions:</strong> 355 (W) x 175 (D) x 60 (H)
+
| style="text-align: left; background: white;" |Old group packaging version: <br><br> [[File:Large-white-cut.png|left|400px]] <br> <strong>Dimensions:</strong> 355 (W) x 175 (D) x 60 (H)
| style="text-align: left; background: white;" | New group packaging version: <br> [[File:Large-eco-cut.png|center|400px]] <br> <strong>Dimensions:</strong> 355 (W) x 175 (D) x 60 (H)
+
| style="text-align: left; background: white;" |New group packaging version: <br> [[File:Large-eco-cut.png|center|400px]] <br> <strong>Dimensions:</strong> 355 (W) x 175 (D) x 60 (H)
 
|-
 
|-
| style="text-align: left; background: white;" | Change reasons
+
| style="text-align: left; background: white;" |Change reasons
| style="text-align: left; background: white;" colspan="2" | The new box is better for the environment
+
| colspan="2" style="text-align: left; background: white;" |The new box is better for the environment
 
|-
 
|-
| style="text-align: left; background: white;" | Product release date
+
| style="text-align: left; background: white;" |Product release date
| style="text-align: left; background: white;" colspan="2" | Devices with new packaging will be released in manufacturing from september with 2 months of transition period. Over this period devices with white packaging can be delivered as well as devices with the new eco boxes.
+
| colspan="2" style="text-align: left; background: white;" |Devices with new packaging will be released in manufacturing from September with 2 months of transition period. Over this period devices with white packaging can be delivered as well as devices with the new eco boxes.
 
|-
 
|-
 
|}
 
|}
Line 157: Line 639:
 
{| class="wikitable"
 
{| class="wikitable"
 
|+
 
|+
! style="text-align: left; background: white;" colspan="3" | Affected products
+
! colspan="3" style="text-align: left; background: white;" |Affected products
 
|-
 
|-
| style="width: 221px; text-align: left; background: white;" | Model
+
| style="width: 221px; text-align: left; background: white;" |Model
| style="width: 448px; text-align: left; background: white;" | Affected order codes
+
| style="width: 448px; text-align: left; background: white;" |Affected order codes
| style="width: 448px; text-align: left; background: white;" | Order code changes
+
| style="width: 448px; text-align: left; background: white;" |Order code changes
 
|-
 
|-
| style="text-align: left; background: white;" | FMB001, FMB010, FMB100, FMB110, FMB120, FMB122, FMB125, FMB202, FMB204, FMB900, FMB920, FMB964, FMT100, FMB130, MTB100.
+
| style="text-align: left; background: white;" |FMB001, FMB010, FMB100, FMB110, FMB120, FMB122, FMB125, FMB202, FMB204, FMB900, FMB920, FMB964, FMT100, FMB130, MTB100.
| style="text-align: left; background: white;" | FMB001******, FMB010******, FMB100******, FMB110******, FMB120******, FMB122******, FMB125******, FMB202******, FMB204******, FMB900******, FMB920******, FMB964******, FMT100******, FMB130******, MTB100******.
+
| style="text-align: left; background: white;" |FMB001******, FMB010******, FMB100******, FMB110******, FMB120******, FMB122******, FMB125******, FMB202******, FMB204******, FMB900******, FMB920******, FMB964******, FMT100******, FMB130******, MTB100******.
| style="text-align: left; background: white;" | No changes
+
| style="text-align: left; background: white;" |No changes
 
|-
 
|-
 
|}
 
|}
Line 171: Line 653:
 
{| class="wikitable"
 
{| class="wikitable"
 
|+
 
|+
! style="text-align: left; background: white;" colspan="3" | Change impact
+
! colspan="3" style="text-align: left; background: white;" |Change impact
 
|-
 
|-
| style="width: 221px; text-align: left; background: white;" | Risk assessment
+
| style="width: 221px; text-align: left; background: white;" |Risk assessment
| style="width: 908px; text-align: left; background: white;" colspan="2"| No risk factors encountered with this change
+
| colspan="2" style="width: 908px; text-align: left; background: white;" |No risk factors encountered with this change
 
|-
 
|-
| style="text-align: left; background: white;" | Suggested implementation plan
+
| style="text-align: left; background: white;" |Suggested implementation plan
| style="text-align: left; background: white;" colspan="2"| Due to the new look of boxes we strongly recommend to update your marketing materials. Because of the new color of the packaging box, if necessary, update your branding materials (stickers, logo layouts).
+
| colspan="2" style="text-align: left; background: white;" |Due to the new look of boxes we strongly recommend to update your marketing materials. Because of the new color of the packaging box, if necessary, update your branding materials (stickers, logo layouts).
 
|-
 
|-
 
|}
 
|}
Line 183: Line 665:
 
{| class="wikitable"
 
{| class="wikitable"
 
|+
 
|+
! style="width: 1141px; text-align: left; background: white;" colspan="3" | Acknowledgement of PCN receipt
+
! colspan="3" style="width: 1141px; text-align: left; background: white;" |Acknowledgement of PCN receipt
 
|-
 
|-
| style="text-align: left; background: white;" colspan="3"| If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
+
| colspan="3" style="text-align: left; background: white;" |If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
 
|-
 
|-
 
|}
 
|}
Line 191: Line 673:
 
==2019.06.14: Device module information display changes==
 
==2019.06.14: Device module information display changes==
  
We would like to inform you, that information display on device module TM2500 will be updated in factory from july 2019.  
+
We would like to inform you, that the information display on device module TM2500 will be updated in the factory from July 2019.  
  
 
{| class="wikitable"
 
{| class="wikitable"
 
|+
 
|+
! style="text-align: left; background: white;" colspan="3" | Change description
+
! colspan="3" style="text-align: left; background: white;" |Change description
 
|-
 
|-
| style="text-align: left; background: white;" | Change type
+
| style="text-align: left; background: white;" |Change type
| style="text-align: left; background: white;" colspan="2" | External/visual
+
| colspan="2" style="text-align: left; background: white;" |External/visual
 
|-
 
|-
| style="width: 221px; text-align: left; background: white;" rowspan="2" | Detailed description
+
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
| style="width: 908px; text-align: left; background: white;" colspan="2" | Information display on TM2500 module will change from sticker to laser print. Information provided on module will remain the same.  
+
| colspan="2" style="width: 908px; text-align: left; background: white;" |Information display on TM2500 module will change from sticker to laser print. Information provided on module will remain the same.
 
|-
 
|-
| style="text-align: left; background: white;" | Old Version: <br>  [[File: TM2500_sticker_v1.png|left|400px]]
+
| style="text-align: left; background: white;" |Old Version: <br>  [[File: TM2500_sticker_v1.png|left|400px]]
| style="text-align: left; background: white;" | New Version: <br>  [[File: TM2500_laser_v1.png|left|400px]]
+
| style="text-align: left; background: white;" |New Version: <br>  [[File: TM2500_laser_v1.png|left|400px]]
 
|-
 
|-
| style="text-align: left; background: white;" | Change reasons
+
| style="text-align: left; background: white;" |Change reasons
| style="text-align: left; background: white;" colspan="2" | Laser printing will increase reliability, speed, and will reduce paper waste.
+
| colspan="2" style="text-align: left; background: white;" |Laser printing will increase reliability, speed, and will reduce paper waste.
 
|-
 
|-
| style="text-align: left; background: white;" | Product release date
+
| style="text-align: left; background: white;" |Product release date
| style="text-align: left; background: white;" colspan="2" | Devices with new module marking will be released in manufacturing from july with 2 months of transition period. Over this period devices with sticker can be delivered as well as devices with laser print.
+
| colspan="2" style="text-align: left; background: white;" |Devices with new module marking will be released in manufacturing from July with 2 months of transition period. Over this period devices with stickers can be delivered as well as devices with laser print.
 
|-
 
|-
 
|}
 
|}
 
{| class="wikitable"
 
{| class="wikitable"
 
|+
 
|+
! style="text-align: left; background: white;" colspan="3" | Affected products
+
! colspan="3" style="text-align: left; background: white;" |Affected products
 
|-
 
|-
| style="width: 448px; text-align: left; background: white;" | Model
+
| style="width: 448px; text-align: left; background: white;" |Model
| style="width: 448px; text-align: left; background: white;" | Affected order codes
+
| style="width: 448px; text-align: left; background: white;" |Affected order codes
| style="width: 221px; text-align: left; background: white;" | Order code changes
+
| style="width: 221px; text-align: left; background: white;" |Order code changes
 
|-
 
|-
| style="text-align: left; background: white;" | FMB001, FMB010, FMB100, FMB110, FMB120, FMB122, FMB125, FMB202, FMB204, FMB900, FMB920, FMB964, FMT100, FMB640, FMB130, MTB100, TMT250, GH5200.
+
| style="text-align: left; background: white;" |FMB001, FMB010, FMB100, FMB110, FMB120, FMB122, FMB125, FMB202, FMB204, FMB900, FMB920, FMB964, FMT100, FMB640, FMB130, MTB100, TMT250, GH5200.
| style="text-align: left; background: white;" | FMB001******, FMB010******, FMB100******, FMB110******, FMB120******, FMB122******, FMB125******, FMB202******, FMB204******, FMB900******, FMB920******, FMB964******, FMT100******, FMB640******, TMT250******, FMB130******, MTB100******, GH5200******.
+
| style="text-align: left; background: white;" |FMB001******, FMB010******, FMB100******, FMB110******, FMB120******, FMB122******, FMB125******, FMB202******, FMB204******, FMB900******, FMB920******, FMB964******, FMT100******, FMB640******, TMT250******, FMB130******, MTB100******, GH5200******.
| style="text-align: left; background: white;" | No changes
+
| style="text-align: left; background: white;" |No changes
 
|-
 
|-
 
|}
 
|}
Line 229: Line 711:
 
{| class="wikitable"
 
{| class="wikitable"
 
|+
 
|+
! style="text-align: left; background: white;" colspan="3" | Change impact
+
! colspan="3" style="text-align: left; background: white;" |Change impact
 
|-
 
|-
| style="width: 221px; text-align: left; background: white;" | Risk assessment
+
| style="width: 221px; text-align: left; background: white;" |Risk assessment
| style="width: 908px; text-align: left; background: white;" colspan="2"| The change will not affect clients. All the module characteristics will remain unchanged. The only sticker on module will be changed to laser print. The displayed information will remain the same.
+
| colspan="2" style="width: 908px; text-align: left; background: white;" |The change will not affect clients. All the module characteristics will remain unchanged. The only sticker on module will be changed to laser print. The displayed information will remain the same.
 
   
 
   
 
|-
 
|-
| style="text-align: left; background: white;" | Suggested implementation plan.
+
| style="text-align: left; background: white;" |Suggested implementation plan.
| style="text-align: left; background: white;" colspan="2"| Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in the customs clearance process.
+
| colspan="2" style="text-align: left; background: white;" |Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in the customs clearance process.
 
|-
 
|-
 
|}
 
|}
Line 242: Line 724:
 
{| class="wikitable"
 
{| class="wikitable"
 
|+
 
|+
! style="width: 1141px; text-align: left; background: white;" colspan="3" | Acknowledgement of PCN receipt
+
! colspan="3" style="width: 1141px; text-align: left; background: white;" |Acknowledgement of PCN receipt
 
|-
 
|-
| style="text-align: left; background: white;" colspan="3"| If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
+
| colspan="3" style="text-align: left; background: white;" |If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
 
|-
 
|-
 
|}
 
|}
  
To download the pdf version of this notification, [[Media: PCN_TM2500_20190614_EN.pdf|click here]].
+
To download the pdf version of this notification, [[Media:PCN TM2500 20190614 EN.pdf|click here]].
  
 
==2019.05.02: new eco friendly box==
 
==2019.05.02: new eco friendly box==
  
Effective May 2019 week 20, FMB920 trackers will be packed with a '''new eco friendly box'''.
+
Effective May 2019 week 20, FMB920 trackers will be packed with a '''new eco-friendly box'''.
  
 
{| class="wikitable"
 
{| class="wikitable"
 
|+
 
|+
! style="text-align: left; background: white;" colspan="3" | Change description
+
! colspan="3" style="text-align: left; background: white;" |Change description
 
|-
 
|-
| style="text-align: left; background: white;" | Change type
+
| style="text-align: left; background: white;" |Change type
| style="text-align: left; background: white;" colspan="2" | Packaging
+
| colspan="2" style="text-align: left; background: white;" |Packaging
 
|-
 
|-
| style="width: 221px; text-align: left; background: white;" rowspan="2" | Detailed description
+
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
| style="width: 908px; text-align: left; background: white;" colspan="2" | Improved and more environmentally friendly packaging box  
+
| colspan="2" style="width: 908px; text-align: left; background: white;" |Improved and more environmentally friendly packaging box
 
|-
 
|-
| style="text-align: left; background: white;" | Old version: <br> [[File:Small white box.png|left|400px]]
+
| style="text-align: left; background: white;" |Old version: <br> [[File:Small white box.png|left|400px]]
| style="text-align: left; background: white;" | New version: <br> [[File:Small-box FM3001.png|left|500px]]
+
| style="text-align: left; background: white;" |New version: <br> [[File:Small-box FM3001.png|left|500px]]
 
|-
 
|-
| style="text-align: left; background: white;" | Change reasons
+
| style="text-align: left; background: white;" |Change reasons
| style="text-align: left; background: white;" colspan="2" | The new box is better for the environment
+
| colspan="2" style="text-align: left; background: white;" |The new box is better for the environment
 
|-
 
|-
| style="text-align: left; background: white;" | Product release date
+
| style="text-align: left; background: white;" |Product release date
| style="text-align: left; background: white;" colspan="2" | May 2019, week 20
+
| colspan="2" style="text-align: left; background: white;" |May 2019, week 20
 
|-
 
|-
 
|}
 
|}
Line 277: Line 759:
 
==2019.04.10: IMEI/SN display on device Changes==
 
==2019.04.10: IMEI/SN display on device Changes==
  
We would like to inform you, that IMEI/SN info display on FMB920 device will be updated in factory from june 2019.  
+
We would like to inform you, that IMEI/SN info display on the FMB920 device will be updated in the factory from June 2019.  
  
 
{| class="wikitable"
 
{| class="wikitable"
 
|+
 
|+
! style="text-align: left; background: white;" colspan="3" | Change description
+
! colspan="3" style="text-align: left; background: white;" |Change description
 
|-
 
|-
| style="text-align: left; background: white;" | Change type
+
| style="text-align: left; background: white;" |Change type
| style="text-align: left; background: white;" colspan="2" | External/visual
+
| colspan="2" style="text-align: left; background: white;" |External/visual
 
|-
 
|-
| style="width: 221px; text-align: left; background: white;" rowspan="3" | Detailed description
+
| rowspan="3" style="width: 221px; text-align: left; background: white;" |Detailed description
| style="width: 908px; text-align: left; background: white;" colspan="2" | IMEI/SN info on device display change  from barcode to QR
+
| colspan="2" style="width: 908px; text-align: left; background: white;" |IMEI/SN info on device display change  from barcode to QR
 
|-
 
|-
| style="text-align: left; background: white;" | Old Version: <br>  [[File:IMEI_SN_Barcode_10x25mm.png|left|400px]]
+
| style="text-align: left; background: white;" |Old Version: <br>  [[File:IMEI_SN_Barcode_10x25mm.png|left|400px]]
| style="text-align: left; background: white;" | New Version: <br>  [[File:IMEI_SN_QR_10x25mm.png|left|400px]]
+
| style="text-align: left; background: white;" |New Version: <br>  [[File:IMEI_SN_QR_10x25mm.png|left|400px]]
 
|-
 
|-
| style="text-align: left; background: white;" colspan="2" | This change will not affect device packing and logistic lists. It will remain as barcode. <br>  [[File:Packing_and_list.png|left|800px]]
+
| colspan="2" style="text-align: left; background: white;" |This change will not affect device packing and logistic lists. It will remain as barcode. <br>  [[File:Packing_and_list.png|left|800px]]
 
|-
 
|-
| style="text-align: left; background: white;" | Change reasons
+
| style="text-align: left; background: white;" |Change reasons
| style="text-align: left; background: white;" colspan="2" | QR format will increase reliability and minimize error rate, because of the error correction feature and improved reading in low contrast.
+
| colspan="2" style="text-align: left; background: white;" |QR format will increase reliability and minimize error rate, because of the error correction feature and improved reading in low contrast.
 
|-
 
|-
 
|-
 
|-
| style="text-align: left; background: white;" | Product release date
+
| style="text-align: left; background: white;" |Product release date
| style="text-align: left; background: white;" colspan="2" | Devices with new QR Code format will be released in manufacturing from June with 2 months of transition period. Over this period devices with barcode can be delivered as well as devices with QR code.  
+
| colspan="2" style="text-align: left; background: white;" |Devices with new QR Code format will be released in manufacturing from June with 2 months of transition period. Over this period devices with barcodes can be delivered as well as devices with QR codes.
 
|-
 
|-
 
|}
 
|}
 
{| class="wikitable"
 
{| class="wikitable"
 
|+
 
|+
! style="text-align: left; background: white;" colspan="3" | Affected products
+
! colspan="3" style="text-align: left; background: white;" |Affected products
 
|-
 
|-
| style="width: 221px; text-align: left; background: white;" | Model
+
| style="width: 221px; text-align: left; background: white;" |Model
| style="width: 448px; text-align: left; background: white;" | Affected order codes
+
| style="width: 448px; text-align: left; background: white;" |Affected order codes
| style="width: 448px; text-align: left; background: white;" | Order code changes
+
| style="width: 448px; text-align: left; background: white;" |Order code changes
 
|-
 
|-
| style="text-align: left; background: white;" | FMB920
+
| style="text-align: left; background: white;" |FMB920
| style="text-align: left; background: white;" | FMB920******
+
| style="text-align: left; background: white;" |FMB920******
| style="text-align: left; background: white;" | No changes
+
| style="text-align: left; background: white;" |No changes
 
|-
 
|-
 
|}
 
|}
Line 318: Line 800:
 
{| class="wikitable"
 
{| class="wikitable"
 
|+
 
|+
! style="text-align: left; background: white;" colspan="3" | Change impact
+
! colspan="3" style="text-align: left; background: white;" |Change impact
 
|-
 
|-
| style="width: 221px; text-align: left; background: white;" | Risk assessment
+
| style="width: 221px; text-align: left; background: white;" |Risk assessment
| style="width: 908px; text-align: left; background: white;" colspan="2"| Risk assessment for devices management required  
+
| colspan="2" style="width: 908px; text-align: left; background: white;" |Risk assessment for devices management required
 
|-
 
|-
| style="text-align: left; background: white;" | Suggested implementation plan
+
| style="text-align: left; background: white;" |Suggested implementation plan
| style="text-align: left; background: white;" colspan="2"| Due to changes in device information display we strongly recommend to check, and prepare your tools to read QR codes.
+
| colspan="2" style="text-align: left; background: white;" |Due to changes in device information display we strongly recommend to check, and prepare your tools to read QR codes.
 
|-
 
|-
 
|}
 
|}
Line 330: Line 812:
 
{| class="wikitable"
 
{| class="wikitable"
 
|+
 
|+
! style="width: 1141px; text-align: left; background: white;" colspan="3" | Acknowledgement of PCN receipt
+
! colspan="3" style="width: 1141px; text-align: left; background: white;" |Acknowledgement of PCN receipt
 
|-
 
|-
| style="text-align: left; background: white;" colspan="3"| If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
+
| colspan="3" style="text-align: left; background: white;" |If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
 
|-
 
|-
 
|}
 
|}
  
To download the pdf version of this notification, [[Media:PCN_FMB920_20190218_EN.pdf|click here]].
+
To download the pdf version of this notification, [[Media:PCN FMB920 20190218 EN.pdf|click here]].
  
 
==2019.03.01: new eco friendly box==
 
==2019.03.01: new eco friendly box==
  
Effective March 2019, FMB920 trackers will be shipped with a '''new eco friendly box'''.
+
Effective March 2019, FMB920 trackers will be shipped with a '''new eco-friendly box'''.
  
 
{| class="wikitable"
 
{| class="wikitable"
 
|+
 
|+
! style="text-align: left; background: white;" colspan="3" | Change description
+
! colspan="3" style="text-align: left; background: white;" |Change description
 
|-
 
|-
| style="text-align: left; background: white;" | Change type
+
| style="text-align: left; background: white;" |Change type
| style="text-align: left; background: white;" colspan="2" | Packaging
+
| colspan="2" style="text-align: left; background: white;" |Packaging
 
|-
 
|-
| style="width: 221px; text-align: left; background: white;" rowspan="2" | Detailed description
+
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
| style="width: 908px; text-align: left; background: white;" colspan="2" | Improved and more environmentally friendly packaging box  
+
| colspan="2" style="width: 908px; text-align: left; background: white;" |Improved and more environmentally friendly packaging box
 
|-
 
|-
| style="text-align: left; background: white;" | Old version: <br> [[File:FMBYX long box blue 1 .png|left|400px]]
+
| style="text-align: left; background: white;" |Old version: <br> [[File:FMBYX long box blue 1 .png|left|400px]]
| style="text-align: left; background: white;" | New version: <br> [[File:FMBYX long box eco.png|center|400px]]
+
| style="text-align: left; background: white;" |New version: <br> [[File:FMBYX long box eco.png|center|400px]]
 
|-
 
|-
| style="text-align: left; background: white;" | Change reasons
+
| style="text-align: left; background: white;" |Change reasons
| style="text-align: left; background: white;" colspan="2" | The new box is better for the environment
+
| colspan="2" style="text-align: left; background: white;" |The new box is better for the environment
 
|-
 
|-
| style="text-align: left; background: white;" | Product release date
+
| style="text-align: left; background: white;" |Product release date
| style="text-align: left; background: white;" colspan="2" | March 2019
+
| colspan="2" style="text-align: left; background: white;" |March 2019
 
|-
 
|-
 
|}
 
|}
Line 365: Line 847:
 
{| class="wikitable"
 
{| class="wikitable"
 
|+
 
|+
! style="text-align: left; background: white;" colspan="3" | Affected products
+
! colspan="3" style="text-align: left; background: white;" |Affected products
 
|-
 
|-
| style="width: 221px; text-align: left; background: white;" | Model
+
| style="width: 221px; text-align: left; background: white;" |Model
| style="width: 448px; text-align: left; background: white;" | Affected order codes
+
| style="width: 448px; text-align: left; background: white;" |Affected order codes
| style="width: 448px; text-align: left; background: white;" | Order code changes
+
| style="width: 448px; text-align: left; background: white;" |Order code changes
 
|-
 
|-
| style="text-align: left; background: white;" | FMB920
+
| style="text-align: left; background: white;" |FMB920
| style="text-align: left; background: white;" | FMB920*******
+
| style="text-align: left; background: white;" |FMB920*******
| style="text-align: left; background: white;" | No changes
+
| style="text-align: left; background: white;" |No changes
 
|-
 
|-
 
|}
 
|}
Line 379: Line 861:
 
{| class="wikitable"
 
{| class="wikitable"
 
|+
 
|+
! style="text-align: left; background: white;" colspan="3" | Change impact
+
! colspan="3" style="text-align: left; background: white;" |Change impact
 
|-
 
|-
| style="width: 221px; text-align: left; background: white;" | Risk assessment
+
| style="width: 221px; text-align: left; background: white;" |Risk assessment
| style="width: 908px; text-align: left; background: white;" colspan="2"| No risk factors encountered with this change
+
| colspan="2" style="width: 908px; text-align: left; background: white;" |No risk factors encountered with this change
 
|-
 
|-
| style="text-align: left; background: white;" | Suggested implementation plan
+
| style="text-align: left; background: white;" |Suggested implementation plan
| style="text-align: left; background: white;" colspan="2"| Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process
+
| colspan="2" style="text-align: left; background: white;" |Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process
 
|-
 
|-
 
|}
 
|}
Line 391: Line 873:
 
{| class="wikitable"
 
{| class="wikitable"
 
|+
 
|+
! style="width: 1141px; text-align: left; background: white;" colspan="3" | Acknowledgement of PCN receipt
+
! colspan="3" style="width: 1141px; text-align: left; background: white;" |Acknowledgement of PCN receipt
 
|-
 
|-
| style="text-align: left; background: white;" colspan="3"| If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
+
| colspan="3" style="text-align: left; background: white;" |If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
 
|-
 
|-
 
|}
 
|}
Line 399: Line 881:
 
==2019.02.20: Top Tampography Changes==
 
==2019.02.20: Top Tampography Changes==
  
We would like to inform you, that tampography of FMB920 device was updated in factory on the 20th of February.  
+
We would like to inform you, that tampography of the FMB920 device was updated in the factory on the 20th of February.  
  
 
{| class="wikitable"
 
{| class="wikitable"
 
|+
 
|+
! style="text-align: left; background: white;" colspan="3" | Change description
+
! colspan="3" style="text-align: left; background: white;" |Change description
 
|-
 
|-
| style="text-align: left; background: white;" | Change type
+
| style="text-align: left; background: white;" |Change type
| style="text-align: left; background: white;" colspan="2" | External/visual
+
| colspan="2" style="text-align: left; background: white;" |External/visual
 
|-
 
|-
| style="width: 221px; text-align: left; background: white;" rowspan="2" | Detailed description
+
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
| style="width: 908px; text-align: left; background: white;" colspan="2" | Top tampography design changed  
+
| colspan="2" style="width: 908px; text-align: left; background: white;" |Top tampography design changed
 
|-
 
|-
| style="text-align: left; background: white;" | Old Version: <br>  [[File:FMB920 black old .png|center|400px]]
+
| style="text-align: left; background: white;" |Old Version: <br>  [[File:FMB920 black old .png|center|400px]]
| style="text-align: left; background: white;" | New Version: <br>  [[File:FMB920 new.png|center|400px]]
+
| style="text-align: left; background: white;" |New Version: <br>  [[File:FMB920 new.png|center|400px]]
 
|-
 
|-
| style="text-align: left; background: white;" | Change reasons
+
| style="text-align: left; background: white;" |Change reasons
| style="text-align: left; background: white;" colspan="2" | 1. Updated Teltonika address to Saltoniskiu st. 9B-1 <br> 2. Added WEEE label. (WEEE - Waste from Electrical and Electronic Equipment)
+
| colspan="2" style="text-align: left; background: white;" |1. Updated Teltonika address to Saltoniskiu st. 9B-1 <br> 2. Added WEEE label. (WEEE - Waste from Electrical and Electronic Equipment)
 
|-
 
|-
 
|-
 
|-
| style="text-align: left; background: white;" | Product release date
+
| style="text-align: left; background: white;" |Product release date
| style="text-align: left; background: white;" colspan="2" | Updated tampographs will be used from the time when the stock will be sold all leftovers. Planned date: week 10
+
| colspan="2" style="text-align: left; background: white;" |Updated tampographs will be used from the time when the stock will be sold all leftovers. Planned date: week 10
 
|-
 
|-
 
|}
 
|}
 
{| class="wikitable"
 
{| class="wikitable"
 
|+
 
|+
! style="text-align: left; background: white;" colspan="3" | Affected products
+
! colspan="3" style="text-align: left; background: white;" |Affected products
 
|-
 
|-
| style="width: 221px; text-align: left; background: white;" | Model
+
| style="width: 221px; text-align: left; background: white;" |Model
| style="width: 448px; text-align: left; background: white;" | Affected order codes
+
| style="width: 448px; text-align: left; background: white;" |Affected order codes
| style="width: 448px; text-align: left; background: white;" | Order code changes
+
| style="width: 448px; text-align: left; background: white;" |Order code changes
 
|-
 
|-
| style="text-align: left; background: white;" | FMB920
+
| style="text-align: left; background: white;" |FMB920
| style="text-align: left; background: white;" | FMB920*******
+
| style="text-align: left; background: white;" |FMB920*******
| style="text-align: left; background: white;" | No changes
+
| style="text-align: left; background: white;" |No changes
 
|-
 
|-
 
|}
 
|}
Line 438: Line 920:
 
{| class="wikitable"
 
{| class="wikitable"
 
|+
 
|+
! style="text-align: left; background: white;" colspan="3" | Change impact
+
! colspan="3" style="text-align: left; background: white;" |Change impact
 
|-
 
|-
| style="width: 221px; text-align: left; background: white;" | Risk assessment
+
| style="width: 221px; text-align: left; background: white;" |Risk assessment
| style="width: 908px; text-align: left; background: white;" colspan="2"| No risk factors encountered with this change
+
| colspan="2" style="width: 908px; text-align: left; background: white;" |No risk factors encountered with this change
 
|-
 
|-
| style="text-align: left; background: white;" | Suggested implementation plan
+
| style="text-align: left; background: white;" |Suggested implementation plan
| style="text-align: left; background: white;" colspan="2"| Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process
+
| colspan="2" style="text-align: left; background: white;" |Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process
 
|-
 
|-
 
|}
 
|}
Line 450: Line 932:
 
{| class="wikitable"
 
{| class="wikitable"
 
|+
 
|+
! style="width: 1141px; text-align: left; background: white;" colspan="3" | Acknowledgement of PCN receipt
+
! colspan="3" style="width: 1141px; text-align: left; background: white;" |Acknowledgement of PCN receipt
 
|-
 
|-
| style="text-align: left; background: white;" colspan="3"| If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
+
| colspan="3" style="text-align: left; background: white;" |If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
 
|-
 
|-
 
|}
 
|}
To download the pdf version of this notification, [[Media:PCN_FMB920_20190205_EN.pdf|click here]].
+
To download the pdf version of this notification, [[Media:PCN FMB920 20190205 EN.pdf|click here]].
  
 
[[Category:FMB920]]
 
[[Category:FMB920]]

Latest revision as of 14:07, 24 January 2024

Main Page > Basic Trackers > FMB920 > FMB920 Product Change Notifications

Product change notifications (PCN) is the way of informing customers of upcoming changes related to Teltonika products. This includes outward appearance adjustments, hardware improvements, firmware changes, changes to package contents, etc. This page stores information regarding changes to the FMB920 tracking device. Below you will find a list of both upcoming and already implemented changes sorted from newest to oldest (top to bottom).

2023.03.08: TOP and BOT casing changes

We would like to inform you, TOP and BOT casing part is updated for FMB920, FMB900, FMC920, FMM920 projects starting from 2023 March.

Change description
Change type Internal/visual
Detailed description TOP and BOT casing parts inner design updated
TOP part:
FMx920 Top.png
BOT part:
FMx920 Bot.png
Changes TOP casing part

1. Unused legacy holes for holes for screws removed to reduce plastic and complexity
2. PCB end support features optimized to reduce plastic and lower the risk of cosmetic defects on the outside
3. Part number and material type (polycarbonate) now shown on the inside of the casing
4. PCB side support design optimized to improve easy of assembly

BOT casing part

1. Unused legacy holes for holes for screws removed to reduce plastic and complexity
2. PCB end support features optimized to reduce plastic and lower the risk of cosmetic defects on the outside
3. Part number and material type (polycarbonate) now shown on the inside of the casing
4. PCB side support design optimized to improve easy of assembly

Product release date March 2023
Affected products
Models Affected order codes Order code changes
FMB920, FMB900, FMC920, FMM920 All order codes No changes for the order codes
Change impact
Risk assessment During the transition period clients might receive devices with old type casing.
Suggested implementation plan No implementation plan needed
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika Telematics may accept that this change has been tacitly accepted and can implement the change as indicated above

2022.12.21: Base firmware update and new accelerometer component support

We would like to inform you about the base firmware update for FMB920 starting from December 21st, 2022. New production firmware version will be 03.27.14.Rev.00

Change description
Change type Firmware update
Detailed description Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMB920_firmware_errata
Old version:
FMB920 03.27.13.Rev.03
New version:
FMB920 03.27.14.Rev.00
Change reasons Assembly optimization to prevent accelerometer compontent shortage in order to ensure stable supply.

Together with assembly update new firmware released to support new accelerometer component.

Product release date 2022 - December Firmware Update with new accelerometer component support
Affected products
Model Affected order codes Order code changes
FMB920 FMB920******* order codes with base Firmware Update firmware
Change impact
Risk assessment During the transition period clients might receive devices with previous Firmware version used in manufacture.
Suggested implementation plan For further assistance, please contact your Teltonika Telematics sales manager or fill query on HelpDesk.

2022.08.01: Base firmware update

We would like to inform you about the base firmware update for FMB920 starting from August 1st, 2022. New production firmware version will be 03.27.13.Rev.03

Change description
Change type Firmware update
Detailed description Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMB920_firmware_errata
Old version:
FMB920 03.27.07.Rev.00
New version:
FMB920 03.27.13.Rev.03
Change reasons FMB920 base firmware version update
Product release date 2022 August
Affected products
Model Affected order codes Order code changes
FMB920 FMB920******* order codes with base Firmware Update firmware

2021.08.13: Base firmware update

We would like to inform you about the base firmware update for FMB920 starting from August 13th, 2021. New production firmware version will be 03.27.07.Rev.00

Change description
Change type Firmware update
Detailed description Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMB920_firmware_errata
Old version:
FMB920 03.25.18.Rev.08
New version:
FMB920 03.27.07.Rev.00
Change reasons FMB920 base firmware version update
Product release date 2021 August
Affected products
Model Affected order codes Order code changes
FMB920 FMB920******* order codes with base Firmware Update firmware
Change impact
Risk assessment Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture.
Suggested implementation plan If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager.

2021.05.17: Base firmware update

We would like to inform you about the base firmware update for FMB920 starting from May 17th, 2021. New production firmware version will be 03.25.18.Rev.08.

Change description
Change type Firmware update
Detailed description Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMB920_firmware_errata
Old version:
03.25.18.Rev.05
New version:
03.25.18.Rev.08
Change reasons FMB920 base firmware version update
Product release date 2021 May.
Affected products
Model Affected order codes Order code changes
FMB920 FMB920******* order codes with base Firmware Update firmware
Change impact
Risk assessment Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically
Suggested implementation plan If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager.


2021.03.02: Base firmware update

We would like to inform you about the base firmware update for FMB920starting from March 03th, 2021. New production firmware version will be 03.25.18.Rev.05.

Change description
Change type Firmware update
Detailed description Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMB920_firmware_errata
Old version:
03.25.15.Rev.32
New version:
03.25.18.Rev.05
Change reasons FMB920 base firmware version update
Product release date 2021 March.
Affected products
Model Affected order codes Order code changes
FMB920 FMB920******* order codes with base Firmware Update firmware
Change impact
Risk assessment Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically
Suggested implementation plan If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager.

2020.11.01: Top Laser Printing Changes

We would like to inform you, that laser printing of the FMB920 device was updated in the factory in November 2020.

Change description
Change type External/visual
Detailed description Top laser printing design changed
Old version:
FMB920 Top laser printing design v1.3.png
New version:
FMB920 Top laser printing design v1.5.png
Change reasons 1. Updated Emark certificate number.
2. Added UKCA label.
3. Updated Teltonika brand to Teltonika Telematics.
Product release date November 2020
Affected products
Model Affected order codes Order code changes
FMB920 FMB920******* New casing
Change impact
Risk assessment No risk factors encountered with this change
Suggested implementation plan Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above

2020.01.22: Base firmware update

We would like to inform you about the base firmware update for FMB920 starting from January 22th, 2020. New production firmware version will be 03.25.15.Rev.01.

Change description
Change type Firmware update
Detailed description Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMB920_firmware_errata
Old version:
FMB920 03.25.05.Rev.00
New version:
FMB920 03.25.15.Rev.01
Change reasons FMB920 base firmware version update
Product release date 2020 January 22th.
Affected products
Model Affected order codes Order code changes
FMB920 FMB920******* order codes with base Firmware Update firmware
Change impact
Risk assessment Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically
Suggested implementation plan If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager.

2019.12.02: new FMB920 case design

Effective December 2019, FMB920 trackers will be shipped with new case design.

Change description
Change type External/visual
Detailed description New design of laser printing. Information provided on module will remain the same
Old version:
FMB920 eng.png
New version:



FMB920 4000x4000.png



Change reasons Uniffication of all Teltonika devices markings
Product release date December 2019
Affected products
Model Affected order codes Order code changes
FMB920 FMB920******* New casing
Change impact
Risk assessment No risk factors encountered with this change
Suggested implementation plan Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above

2019.10.09: Top Device Marking Changes

We would like to inform you, that tampography of the FMB920 device was updated to engraving in the factory on the 8th of October.

Change description
Change type External/visual
Detailed description Device marking changed from tampography to laser printing. Information provided on module will remain the same
Old Version:
FMB920 600x600 PNG 1.png
New Version:
FMB920 eng.png
Change reasons To improve manufacturing speed, efficiency and reliability

To increase quality, precision and durability of marking.

Product release date Planned date: 2019 October
Affected products
Model Affected order codes Order code changes
FMB920 FMB920******* No changes
Change impact
Risk assessment No risk factors encountered with this change
Suggested implementation plan No implementation plan needed
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above

To download the pdf version of this notification, click here.

2019.08.14: Top Tampography Changes

We would like to inform you, that tampography of the FMB920 device was updated in the factory on the 5th of August.

Change description
Change type External/visual
Detailed description Top tampography design changed
Old Version:
FMB920 new.png
New Version:
FMB920 new2.png
Change reasons 1. Updated Emark certificate number.
Product release date Updated tampographs will be used from the time when the stock will be sold all leftovers. Planned date: 35 week
Affected products
Model Affected order codes Order code changes
FMB920 FMB920******* No changes
Change impact
Risk assessment No risk factors encountered with this change
Suggested implementation plan Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above

To download the pdf version of this notification, click here.

2019.07.22: new no brand Eco friendly boxes

Effective September 2019, FMB920 trackers with no brand packaging will be shipped with a new no brand eco-friendly box.

Change description
Change type Packaging
Detailed description Improved and more environmentally friendly packaging box
Old single packaging version:

Small-white-cut.png

Dimensions: 165 (W) x 145 (D) x 35 (H)
New single packaging version:
Small-eco-cut.png

Dimensions: 175 (W) x 150 (D) x 35 (H)
Old group packaging version:

Large-white-cut.png

Dimensions: 355 (W) x 175 (D) x 60 (H)
New group packaging version:
Large-eco-cut.png

Dimensions: 355 (W) x 175 (D) x 60 (H)
Change reasons The new box is better for the environment
Product release date Devices with new packaging will be released in manufacturing from September with 2 months of transition period. Over this period devices with white packaging can be delivered as well as devices with the new eco boxes.
Affected products
Model Affected order codes Order code changes
FMB001, FMB010, FMB100, FMB110, FMB120, FMB122, FMB125, FMB202, FMB204, FMB900, FMB920, FMB964, FMT100, FMB130, MTB100. FMB001******, FMB010******, FMB100******, FMB110******, FMB120******, FMB122******, FMB125******, FMB202******, FMB204******, FMB900******, FMB920******, FMB964******, FMT100******, FMB130******, MTB100******. No changes
Change impact
Risk assessment No risk factors encountered with this change
Suggested implementation plan Due to the new look of boxes we strongly recommend to update your marketing materials. Because of the new color of the packaging box, if necessary, update your branding materials (stickers, logo layouts).
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above

2019.06.14: Device module information display changes

We would like to inform you, that the information display on device module TM2500 will be updated in the factory from July 2019.

Change description
Change type External/visual
Detailed description Information display on TM2500 module will change from sticker to laser print. Information provided on module will remain the same.
Old Version:
TM2500 sticker v1.png
New Version:
TM2500 laser v1.png
Change reasons Laser printing will increase reliability, speed, and will reduce paper waste.
Product release date Devices with new module marking will be released in manufacturing from July with 2 months of transition period. Over this period devices with stickers can be delivered as well as devices with laser print.
Affected products
Model Affected order codes Order code changes
FMB001, FMB010, FMB100, FMB110, FMB120, FMB122, FMB125, FMB202, FMB204, FMB900, FMB920, FMB964, FMT100, FMB640, FMB130, MTB100, TMT250, GH5200. FMB001******, FMB010******, FMB100******, FMB110******, FMB120******, FMB122******, FMB125******, FMB202******, FMB204******, FMB900******, FMB920******, FMB964******, FMT100******, FMB640******, TMT250******, FMB130******, MTB100******, GH5200******. No changes
Change impact
Risk assessment The change will not affect clients. All the module characteristics will remain unchanged. The only sticker on module will be changed to laser print. The displayed information will remain the same.
Suggested implementation plan. Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in the customs clearance process.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above

To download the pdf version of this notification, click here.

2019.05.02: new eco friendly box

Effective May 2019 week 20, FMB920 trackers will be packed with a new eco-friendly box.

Change description
Change type Packaging
Detailed description Improved and more environmentally friendly packaging box
Old version:
Small white box.png
New version:
Small-box FM3001.png
Change reasons The new box is better for the environment
Product release date May 2019, week 20

2019.04.10: IMEI/SN display on device Changes

We would like to inform you, that IMEI/SN info display on the FMB920 device will be updated in the factory from June 2019.

Change description
Change type External/visual
Detailed description IMEI/SN info on device display change from barcode to QR
Old Version:
IMEI SN Barcode 10x25mm.png
New Version:
IMEI SN QR 10x25mm.png
This change will not affect device packing and logistic lists. It will remain as barcode.
Packing and list.png
Change reasons QR format will increase reliability and minimize error rate, because of the error correction feature and improved reading in low contrast.
Product release date Devices with new QR Code format will be released in manufacturing from June with 2 months of transition period. Over this period devices with barcodes can be delivered as well as devices with QR codes.
Affected products
Model Affected order codes Order code changes
FMB920 FMB920****** No changes
Change impact
Risk assessment Risk assessment for devices management required
Suggested implementation plan Due to changes in device information display we strongly recommend to check, and prepare your tools to read QR codes.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above

To download the pdf version of this notification, click here.

2019.03.01: new eco friendly box

Effective March 2019, FMB920 trackers will be shipped with a new eco-friendly box.

Change description
Change type Packaging
Detailed description Improved and more environmentally friendly packaging box
Old version:
FMBYX long box blue 1 .png
New version:
FMBYX long box eco.png
Change reasons The new box is better for the environment
Product release date March 2019
Affected products
Model Affected order codes Order code changes
FMB920 FMB920******* No changes
Change impact
Risk assessment No risk factors encountered with this change
Suggested implementation plan Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above

2019.02.20: Top Tampography Changes

We would like to inform you, that tampography of the FMB920 device was updated in the factory on the 20th of February.

Change description
Change type External/visual
Detailed description Top tampography design changed
Old Version:
FMB920 black old .png
New Version:
FMB920 new.png
Change reasons 1. Updated Teltonika address to Saltoniskiu st. 9B-1
2. Added WEEE label. (WEEE - Waste from Electrical and Electronic Equipment)
Product release date Updated tampographs will be used from the time when the stock will be sold all leftovers. Planned date: week 10
Affected products
Model Affected order codes Order code changes
FMB920 FMB920******* No changes
Change impact
Risk assessment No risk factors encountered with this change
Suggested implementation plan Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above

To download the pdf version of this notification, click here.