Changes

Line 2: Line 2:  
| product_name  = FMM230 tracking device
 
| product_name  = FMM230 tracking device
 
}}
 
}}
 +
 +
 +
==2024.01.22: Modified battery placement within the casing==
 +
We would like to inform you that starting from January 2024, there will be a small change in the FMM230 devices casing. We have adjusted the battery placement and increased PCB guide height within casing. This modification was essential to enhance our manufacturing process.
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change description
 +
|-
 +
| style="text-align: left; background: white;" |Change type
 +
| colspan="2" style="text-align: left; background: white;" |Optimizing robotic battery placement process within casing
 +
|-
 +
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |The modifications will not impact the place of the battery or PCB within the FMM230 device.
 +
|-
 +
| style="text-align: left; background: white;" |Old Version: [[File:FMX - OLD.jpg|center|250px]]                                                     
 +
| style="text-align: left; background: white;" |New Version: [[File:FMX - NEW.jpg|center|250px]] [[File:FMX - NEW 2.jpg|center|250px]]                                                                                   
 +
|-
 +
| style="text-align: left; background: white;" |Change reasons
 +
| colspan="2" style="text-align: left; background: white;" |
 +
# Modified battery placement within the casing.
 +
# PCB guide height increased for easier assembly.
 +
# Improved manufacturing process.
 +
|-
 +
| style="text-align: left; background: white;" |Product release date
 +
| colspan="2" style="text-align: left; background: white;" |January, 2024
 +
|-
 +
|}
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Affected products
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Model
 +
| style="width: 448px; text-align: left; background: white;" |Affected order codes
 +
| style="width: 448px; text-align: left; background: white;" |Order code changes
 +
|-
 +
| style="text-align: left; background: white;" |FMM230
 +
| style="text-align: left; background: white;" |FMM230 all codes
 +
| style="text-align: left; background: white;" | Modified battery placement and PCB guide height within the casing.
 +
|-
 +
|}
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change impact
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Risk assessment
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |During transition period clients might receive devices with previous casing design. The transition period can last from January to February inclusive.
 +
|-
 +
| style="text-align: left; background: white;" |Suggested implementation plan
 +
| colspan="2" style="text-align: left; background: white;" |No implementation plan is needed.
 +
|-
 +
|}
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="width: 1141px; text-align: left; background: white;" |Acknowledgement of PCN receipt
 +
|-
 +
| colspan="3" style="text-align: left; background: white;" |If no feedback is received within two weeks after the issue date of this notification – Teltonika may accept that this change has tactically accepted and can implement the change as indicated above.
 +
|}
 +
 +
==2024.01.26: Base firmware update==
 +
We would like to inform you about the base firmware update for FMM230 starting from January 26th, 2024. New production firmware version will be '''03.29.00.Rev.14'''
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change description
 +
|-
 +
| style="text-align: left; background: white;" |Change type
 +
| colspan="2" style="text-align: left; background: white;" |Firmware update
 +
|-
 +
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |Key improvements from last production firmware are listed in errata: [[FMM230_firmware_errata]]
 +
|-
 +
| style="text-align: left; background: white;" |Old version:
 +
FMM230 03.27.13.Rev.03
 +
| style="text-align: left; background: white;" |New version:
 +
FMM230 03.29.00.Rev.14
 +
|-
 +
| style="text-align: left; background: white;" |Change reasons
 +
| colspan="2" style="text-align: left; background: white;" |FMM230 base firmware version update
 +
|-
 +
| style="text-align: left; background: white;" |Product release date
 +
| colspan="2" style="text-align: left; background: white;" |2024 January
 +
|-
 +
|}
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Affected products
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Model
 +
| style="width: 448px; text-align: left; background: white;" |Affected order codes
 +
| style="width: 448px; text-align: left; background: white;" |Order code changes
 +
|-
 +
| style="text-align: left; background: white;" |FMM230
 +
| style="text-align: left; background: white;" |FMM230******* order codes with base Firmware
 +
| style="text-align: left; background: white;" |Update firmware
 +
|-
 +
|}
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change impact
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Risk assessment
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture.
 +
|-
 +
| style="text-align: left; background: white;" |Suggested implementation plan
 +
| colspan="2" style="text-align: left; background: white;" |If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager.
 +
|-
 +
|}
 +
{| class="wikitable"
 +
! colspan="3" style="text-align: left; background: white;" |Acknowledgement of PCN receipt
 +
| colspan="1" style="width: 908px; text-align: left; background: white;" |If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
 +
|-
 +
|}
 +
 
==2023.12.13: Certification Engraving Update==
 
==2023.12.13: Certification Engraving Update==
   Line 12: Line 127:  
|-
 
|-
 
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
 
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
| colspan="2" style="width: 908px; text-align: left; background: white;" |The specifications of laser engraving devices have undergone modifications subsequent to their certification by Anatel and Bluetooth SIG, ensuring compliance with rigorous standards. These changes affect FMM230-Q3IB0 and FMM230-Q3IB0 devices.
+
| colspan="2" style="width: 908px; text-align: left; background: white;" |The specifications of laser engraving devices have undergone modifications subsequent to their certification by Anatel and Bluetooth® SIG, ensuring compliance with rigorous standards. These changes affect FMM130-QG5 and FMM230-Q3IB0 devices.
 
|-
 
|-
| style="text-align: left; background: white;" |Old laser engraving: <br>  [[OLD]]
+
| style="text-align: left; background: white;" |Old laser engraving: <br>  [[File:FMM230 OLD OLD.png]]  
| style="text-align: left; background: white;" |New laser engraving: <br>  [[NEW]]
+
| style="text-align: left; background: white;" |New laser engraving: <br>  [[File:FMM230 NEW BT.png]]
 
|-
 
|-
 
| style="text-align: left; background: white;" |Change reasons
 
| style="text-align: left; background: white;" |Change reasons
| colspan="2" style="text-align: left; background: white;" |The devices have received approval from both Anatel certification and compliance with the Bluetooth SIG standard. These changes affect FMM130-QG5 and FMM230-Q3IB0 devices.
+
| colspan="2" style="text-align: left; background: white;" |The devices have received approval from both Anatel certification and compliance with the Bluetooth® SIG standard. These changes affect FMM130-QG5 and FMM230-Q3IB0 devices.
 
|-
 
|-
 
| style="text-align: left; background: white;" |Release date
 
| style="text-align: left; background: white;" |Release date
Line 58: Line 173:  
|-
 
|-
 
|}
 
|}
  −
  −
      
==2022.09.19: Base firmware update==
 
==2022.09.19: Base firmware update==