Changes

m
Protected "Template:FM36M1 Accessories" ([Edit=Allow only administrators] (indefinite) [Move=Allow only administrators] (indefinite))
Line 18: Line 18:  
|-
 
|-
 
| style="text-align: left; vertical-align: top;" | A fuel tank level sensor exists in most cars, which shows the approximate fuel level in the driver’s indicator panel. It is possible to connect Analog input to {{{model|FM36YX}}} (if sensor returns analogue signal proportional to fuel level). Figure 10 shows the connection scheme to the {{{model|FM36YX}}} and fuel tank sensor through Analog input 1. After the connection to the tank fuel level sensor, calibration is needed. Calibration is needed because most fuel tank sensors are not linear. Calibration is performed by measuring voltage dependence on volume of fuel in tank.
 
| style="text-align: left; vertical-align: top;" | A fuel tank level sensor exists in most cars, which shows the approximate fuel level in the driver’s indicator panel. It is possible to connect Analog input to {{{model|FM36YX}}} (if sensor returns analogue signal proportional to fuel level). Figure 10 shows the connection scheme to the {{{model|FM36YX}}} and fuel tank sensor through Analog input 1. After the connection to the tank fuel level sensor, calibration is needed. Calibration is needed because most fuel tank sensors are not linear. Calibration is performed by measuring voltage dependence on volume of fuel in tank.
| style="text-align: left; vertical-align: top;" | [[Image:Sch_fmb1yx_lls.png|250px|center]]
+
| style="text-align: left; vertical-align: top;" | [[Image:fuel sensor for FM36M1.png|250px|center]]
 
|-
 
|-
 
! style="text-align: left; vertical-align: top;" | Alarm buttons, door sensors etc.
 
! style="text-align: left; vertical-align: top;" | Alarm buttons, door sensors etc.
Line 24: Line 24:  
|-
 
|-
 
| style="text-align: left; vertical-align: top;" | Alarm buttons, door sensors, ignition, etc. have two output states: high or low. {{{model|FM36YX}}} Digital inputs are used to detect these states.
 
| style="text-align: left; vertical-align: top;" | Alarm buttons, door sensors, ignition, etc. have two output states: high or low. {{{model|FM36YX}}} Digital inputs are used to detect these states.
| style="text-align: left; vertical-align: top;" | [[Image:Sch_fmb1yx_panic.png|400px|center]]
+
| style="text-align: left; vertical-align: top;" | [[Image:FM36M1_panic_buttont_connection.png|400px|center]]
 
|-
 
|-
 
! style="text-align: left; vertical-align: top;" | Relays
 
! style="text-align: left; vertical-align: top;" | Relays
Line 30: Line 30:  
|-
 
|-
 
| style="text-align: left; vertical-align: top;" | In cases when sensor output signal is negative, an additional relay has to be installed to convert negative signal to positive.
 
| style="text-align: left; vertical-align: top;" | In cases when sensor output signal is negative, an additional relay has to be installed to convert negative signal to positive.
| style="text-align: left; vertical-align: top;" | [[Image:Sch_fmb1yx_inv_relay.png|400px|center]]  
+
| style="text-align: left; vertical-align: top;" | [[Image:inverting_relay_FM36.png|400px|center]]  
 
|-
 
|-
 
! style="text-align: left; vertical-align: top;" | Immobilizer relay
 
! style="text-align: left; vertical-align: top;" | Immobilizer relay
Line 49: Line 49:  
|-
 
|-
 
| style="text-align: left; vertical-align: top;" rowspan=5 | {{{oneWire|One of the implemented features on {{{model|FM36YX}}} is 1-Wire® data protocol, which enables connection to devices such as thermometer (DS1820, DS18S20 and DS18B20) and I-Button DS1990A. }}}
 
| style="text-align: left; vertical-align: top;" rowspan=5 | {{{oneWire|One of the implemented features on {{{model|FM36YX}}} is 1-Wire® data protocol, which enables connection to devices such as thermometer (DS1820, DS18S20 and DS18B20) and I-Button DS1990A. }}}
| style="text-align: left; vertical-align: top;" | {{{oneWire| {{{pic_ds1820|[[Image:Sch_fmb120_ds1820.png|400px|center]]}}} }}}
+
| style="text-align: left; vertical-align: top;" | {{{oneWire| {{{pic_ds1820|[[Image:DS1820_FM36M1.png|400px|center]]}}} }}}
 
|-  
 
|-  
 
| style="text-align: left; vertical-align: top;" | {{{oneWire| TTJ sensor pinout }}}
 
| style="text-align: left; vertical-align: top;" | {{{oneWire| TTJ sensor pinout }}}
 
|-
 
|-
| style="text-align: left; vertical-align: top;" | {{{oneWire| [[Image:Ttj_pinout.png|400px|center]] }}}
+
| style="text-align: left; vertical-align: top;" | {{{oneWire| [[Image:Ttj_pinout_FM36.png|400px|center]] }}}
 
|-
 
|-
 
! style="text-align: left; vertical-align: top;" | {{{oneWire| I-Button DS1990A connection to {{{model|FM36YX}}} }}}
 
! style="text-align: left; vertical-align: top;" | {{{oneWire| I-Button DS1990A connection to {{{model|FM36YX}}} }}}
 
|-
 
|-
| style="text-align: left; vertical-align: top;" | {{{oneWire| [[Image:Sch_fmb1yx_ibutton.png|400px|center]] }}}
+
| style="text-align: left; vertical-align: top;" | {{{oneWire| [[Image:Ibutton_FM36M1.png|400px|center]] }}}
 
|-
 
|-
 
|}
 
|}