Essential fields in ‘SMS’ part are ‘Login’ and ‘Password’. The login and password are used
+
Essential fields in ‘SMS’ part are ‘Login’ and ‘Password’. The login and password are used with every SMS sent to FM3612. If login and password are not set, in every SMS sent to FM3612 device two spaces before command have to be used (<space><space><command>). Command structure with set login and password: <login><space><password><space><command>, example: “opa opa getgps” Phone numbers have to be written in international standard, without using “+” or “00” signs in prefix. If no numbers are entered, configuration and sending commands over SMS are allowed from all GSM numbers. SMS data sending settings – enable or disable periodic data and event SMS usage. This setting does not affect replies to SMS request messages – answers are always sent back to sender telephone number. FM3612 can send binary SMS with 24-coordinates-in-one-SMS. It is used in areas where no GPRS coverage is available. Module collects data and sends to server binary SMS containing information about last 24 collected points. SMS sending schedule is set in SMS Week Time tab and used Time zone is set in SMS Time Zone. 24-Coordinates SMS decoding is described in device protocols documentation. Please contact Teltonika sale manager to find out more about protocols documentation purchase
with every SMS sent to FM3612. If login and password are not set, in every SMS sent to FM3612
 
device two spaces before command have to be used (<space><space><command>).
 
Command structure with set login and password:
 
<login><space><password><space><command>, example: “opa opa getgps”
 
Phone numbers have to be written in international standard, without using “+” or “00”
 
signs in prefix. If no numbers are entered, configuration and sending commands over SMS are
 
allowed from all GSM numbers.
 
SMS data sending settings – enable or disable periodic data and event SMS usage. This
 
setting does not affect replies to SMS request messages – answers are always sent back to
 
sender telephone number.
 
FM3612 can send binary SMS with 24-coordinates-in-one-SMS. It is used in areas where no
 
GPRS coverage is available. Module collects data and sends to server binary SMS containing
 
information about last 24 collected points. SMS sending schedule is set in SMS Week Time tab
 
and used Time zone is set in SMS Time Zone. 24-Coordinates SMS decoding is described in device
 
protocols documentation. Please contact Teltonika sale manager to find out more about
 
protocols documentation purchase
 
 
<br><br>
 
<br><br>
 
'''FIGURE'''
 
'''FIGURE'''
 +
[[Image:FM36YX_SMS_configration.png]]
 +
<br><br>
 
'''Table'''
 
'''Table'''
 +
 +
<font size="+1">
 +
{| class="wikitable" style="border-style: solid; border-width: 0px"
 +
|+
 +
|-
 +
| style="text-align: left; background: #F6F6FB;"        | [[Image:Bw_nb.png|50px]]
 +
| style="text-align: left; background: #F6F6FB;"        | Note: A mobile phone will not understand SMS with binary code, so sending it to a mobile phone is useless. When sending a binary SMS to a phone number, which is a server phone number, the server can interpret and understand binary code, so the data can be read and you can view it on the server.
 +
|-
 +
| style="text-align: left; background: #F6F6FB;"        | [[Image:Bw_nb.png|50px]]
 +
| style="text-align: left; background: #F6F6FB;"        | SMS login and password and authorized number list are used to protect FM3612 module from unauthorized access. Module accepts messages only from a list of authorized numbers and with proper module login and password. Numbers must be without “+” or “00” prefix. If no authorized numbers are entered, module accepts messages from all numbers.
 +
 +
|}
 +
</font>

Revision as of 14:09, 31 May 2018

Essential fields in ‘SMS’ part are ‘Login’ and ‘Password’. The login and password are used with every SMS sent to FM3612. If login and password are not set, in every SMS sent to FM3612 device two spaces before command have to be used (<space><space><command>). Command structure with set login and password: <login><space><password><space><command>, example: “opa opa getgps” Phone numbers have to be written in international standard, without using “+” or “00” signs in prefix. If no numbers are entered, configuration and sending commands over SMS are allowed from all GSM numbers. SMS data sending settings – enable or disable periodic data and event SMS usage. This setting does not affect replies to SMS request messages – answers are always sent back to sender telephone number. FM3612 can send binary SMS with 24-coordinates-in-one-SMS. It is used in areas where no GPRS coverage is available. Module collects data and sends to server binary SMS containing information about last 24 collected points. SMS sending schedule is set in SMS Week Time tab and used Time zone is set in SMS Time Zone. 24-Coordinates SMS decoding is described in device protocols documentation. Please contact Teltonika sale manager to find out more about protocols documentation purchase

FIGURE FM36YX SMS configration.png

Table

Bw nb.png Note: A mobile phone will not understand SMS with binary code, so sending it to a mobile phone is useless. When sending a binary SMS to a phone number, which is a server phone number, the server can interpret and understand binary code, so the data can be read and you can view it on the server.
Bw nb.png SMS login and password and authorized number list are used to protect FM3612 module from unauthorized access. Module accepts messages only from a list of authorized numbers and with proper module login and password. Numbers must be without “+” or “00” prefix. If no authorized numbers are entered, module accepts messages from all numbers.