Template:FM36 Features Parameters

From Wiki Knowledge Base | Teltonika GPS

Green Drivind scenario

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
ID U8 default min max 0 – value = 0 Name
1 – value = 1
ID U8 default min max Value Name
1600 U8 0 0 3 0 – disable Green Driving scenario
1 – Dout not control scenario
2 – Dout1 controls scenario
3 – Dout2 controls scenario
1602 Float 0.25 0.25 0.85 G Max Acceleration Force
1603 Float 0.25 0.35 0.85 G Max Braking Force
1604 U16 0.3 0.1 1.0 rad/second Max Cornering Force

Over Speeding

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1601 U8 0 0 3 0 – disable OverSpeeding scenario
1 – Dout not control scenario
2 – Dout1 controls scenario
3 – Dout2 controls scenario
1605 U16 0 0 260 km/h Max Cornering Force

Jamming

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1606 U8 0 0 3 0 – disable Jamming detection scenario
1 – Dout not control scenario
2 – Dout1 controls scenario
3 – Dout2 controls scenario

Immobilizer

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1607 U8 0 0 3 0 – disable Immobilizer scenario
1 – Dout not control scenario
2 – Dout1 controls scenario
3 – Dout2 controls scenario
1609 U8 30 5 65535 seconds Immobilizer ignition timeout
1608 U8 0 0 1 0 – disable iButton list checking scenario
1 – enabled