Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
2000 S8 1 0 3 0 – Disabled I/O#1 Priority
1 – Low
2 – High
3 – Panic
2001 S32 0 -2147483647 2147483647 I/O#1 High level
2002 S32 0 -2147483647 2147483647 I/O#1 Low level
2003 S8 3 0 5 0 – On Exit I/O#1 event generation type
1 – On Entrance
2 – On Both
3 – Monitoring
4 – Hysteresis
5 – On Change
2004 S32 10 0 2592000 I/O#1 Low level
I/O Element Number I/O element parameters
Digital Input 1 2000-2004