Difference between revisions of "Template:FM36 I/O parameters Parameters"

From Wiki Knowledge Base | Teltonika GPS
Line 83: Line 83:
 
! style="text-align: center; vertical-align: center;" |Digital Input 2
 
! style="text-align: center; vertical-align: center;" |Digital Input 2
 
| style="text-align: center; vertical-align: center;" |2010-2014
 
| style="text-align: center; vertical-align: center;" |2010-2014
 +
|-
 +
! style="text-align: center; vertical-align: center;" |
 +
| style="text-align: center; vertical-align: center;" |
 
|-
 
|-
 
|}
 
|}

Revision as of 10:22, 4 June 2018

I/O properties are additional data sources which are recorded along with usual GPS data.

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
2000 S8 1 0 3 0 – Disabled I/O#1 Priority
1 – Low
2 – High
3 – Panic
2001 S32 0 -2147483647 2147483647 I/O#1 High level
2002 S32 0 -2147483647 2147483647 I/O#1 Low level
2003 S8 3 0 5 0 – On Exit I/O#1 event generation type
1 – On Entrance
2 – On Both
3 – Monitoring
4 – Hysteresis
5 – On Change
2004 S32 10 0 2592000 I/O#1 Low level

Other I/O property elements can be configured in same logic. All I/O element parameters are listed in the next table.

I/O Element Number I/O element parameters
Digital Input 1 2000-2004
Digital Input 2 2010-2014