Template:FM36 I/O parameters Parameters

From Wiki Knowledge Base | Teltonika GPS

I/O properties are additional data sources which are recorded along with usual GPS data.

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
2000 S8 1 0 3 0 – Disabled I/O#1 Priority
1 – Low
2 – High
3 – Panic
2001 S32 0 -2147483647 2147483647 I/O#1 High level
2002 S32 0 -2147483647 2147483647 I/O#1 Low level
2003 S8 3 0 5 0 – On Exit I/O#1 event generation type
1 – On Entrance
2 – On Both
3 – Monitoring
4 – Hysteresis
5 – On Change
2004 S32 10 0 2592000 I/O#1 Low level

Other I/O property elements can be configured in same logic. All I/O element parameters are listed in the next table.

I/O Element Number I/O element parameters
Digital Input 1 2000-2004
Digital Input 2 2010-2014
Digital Input 3 2020-2024
Digital Input 4 2030-2034
Analog Input 1 2040-2044
Digital Output 1 2050-2054
Digital Output 2 2060-2064
GNSS PDOP 2070-2074
GNSS HDOP 2080-2084
External Voltage 2090-2094
GNSS Power 2100-2104
Movement Sensor 2110-2114
Odometer Value 2120-2124