Line 187: Line 187:
 
         <td style="width: 8%; text-align:left"></td>
 
         <td style="width: 8%; text-align:left"></td>
 
         <td style="width: 8%; text-align:left; vertical-align:middle">mA</td>
 
         <td style="width: 8%; text-align:left; vertical-align:middle">mA</td>
 +
</tr>
 +
<tr>
 +
        <td colspan="5" style="vertical-align:middle">RS232/RS485 Input Voltage:</td>
 +
</tr>
 +
<tr>
 +
        <td style="text-align:left">RS232 input voltage range (common-mode voltage)</td>
 +
        <td style="width: 8%; text-align:left">-15</td>
 +
        <td style="width: 8%; text-align:left; vertical-align:middle"></td>
 +
        <td style="width: 8%; text-align:left">+15</td>
 +
        <td style="width: 8%; text-align:left; vertical-align:middle">V</td>
 +
</tr>
 +
<tr>
 +
        <td style="text-align:left">RS485 input voltage range on A or B pin (common-mode voltage)</td>
 +
        <td style="width: 8%; text-align:left">-7</td>
 +
        <td style="width: 8%; text-align:left; vertical-align:middle"></td>
 +
        <td style="width: 8%; text-align:left">+12</td>
 +
        <td style="width: 8%; text-align:left; vertical-align:middle">V</td>
 
</tr>
 
</tr>
 
</table>
 
</table>

Revision as of 16:11, 2 March 2022

Electrical characteristics


Characteristic description Value
Min. Typ. Max. Unit
Supply Voltage:
Supply Voltage
(Recommended Operating Conditions)
+10 +30 V
Digital Output (Open Drain grade):
Drain current (Digital Output OFF) 120 µA
Drain current
(Digital Output ON, Recommended Operating Conditions)
0.1 0.5 A
Static Drain-Source resistance
(Digital Output ON)
400 600
Digital Input:
Input resistance (DIN1) 47
Input voltage
(Recommended Operating Conditions)
0 Supply voltage V
Input Voltage threshold (DIN1) 7.5 V
Analog Input:
Input voltage
(Recommended Operating Conditions), Range 1
0 +10 V
Input resistance, Range 1 150
Measurement error on 12V, Range 1 3 %
Additional error on 12 V, Range 1 360 mV
Measurement error on 30 V, Range 1 3 %
Additional error on 30 V, Range 1 900 mV
Input Voltage
(Recommended Operating Conditions), Range 2
0 +30 V
Input resistance, Range 2 150
Measurement error on 12V, Range 2 3 %
Additional error on 12 V, Range 2 360 mV
Measurement error on 30 V, Range 2 3 %
Additional error on 30 V, Range 2 900 mV
Output Supply Voltage 1-Wire:
Supply voltage +4.5 +4.7 V
Output inner resistance 7 Ω
Output current (Uout > 3.0 V) 30 mA
Short circuit current (Uout = 0) 75 mA
RS232/RS485 Input Voltage:
RS232 input voltage range (common-mode voltage) -15 +15 V
RS485 input voltage range on A or B pin (common-mode voltage) -7 +12 V


Alert.png
Analog Input error margin can increase if temperature varies.

Absolute maximum ratings

Characteristic description Value
Min. Typ. Max. Unit
Supply Voltage
(Absolute Maximum Ratings)
-32 +32 V
Drain-Source clamp threshold voltage
(Absolute Maximum Ratings), (Idrain = 2 mA)
+36 V
Digital Input Voltage
(Absolute Maximum Ratings)
-32 +32 V
Analog Input Voltage
(Absolute Maximum Ratings)
-32 +32 V