| style="text-align: left; vertical-align: top;" | {{{oneWire| {{{pic_ds1820|[[Image:Sch_fmb20x_ds1820.png|400px|center]]}}} }}}
 
| style="text-align: left; vertical-align: top;" | {{{oneWire| {{{pic_ds1820|[[Image:Sch_fmb20x_ds1820.png|400px|center]]}}} }}}
 
|-  
 
|-  
| style="text-align: left; vertical-align: top;" | {{{oneWire| TTJ sensor pinout }}}
+
| style="text-align: left; vertical-align: top;" | {{{oneWire| '''TTJ sensor pinout''' }}}
 
|-
 
|-
 
| style="text-align: left; vertical-align: top;" | {{{oneWire| [[Image:Ttj_fmb20x_pinout.png|400px|center]] }}}
 
| style="text-align: left; vertical-align: top;" | {{{oneWire| [[Image:Ttj_fmb20x_pinout.png|400px|center]] }}}

Revision as of 09:46, 29 May 2018

Bw nb.png Please order accessories separately as they are not included into device package.


Accessory and its description Accessory connection schematic
Fuel tank sensors Fuel sensor connection to FMB20X
A fuel tank level sensor which indicates the approximate fuel level on the driver's indicator panel exists in most cars. If the sensor returns analogue signal proportional to fuel level it can be connected to FMB20X Analog input. After connection to the tank fuel level sensor a calibration is needed because most fuel tank sensors are not linear. Calibration is performed by measuring voltage values resulting from the volume of fuel in tank.
Sch fmb20x lls.png
Alarm buttons, door sensors etc. Panic button connection to FMB20X
Alarm buttons, door sensors, ignition, etc. have two output states: high or low. FMB20X Digital inputs are used to detect these states.
Sch fmb20x panic.png
Relays Inverting relay connection to FMB20X
In cases when sensor output signal is negative, an additional relay has to be installed to convert negative signal to positive.
Sch fmb20x inv relay.png
Immobilizer relay Immobilizer relay connection to FMB20X output
When connected as shown on the right hand side, FMB20X disables engine starter when output is ON.
Sch fmb1yx imb relay.png
Automotive relay Automotive relay pinout
An ordinary automotive relay is used to invert input signal or to immobilize engine starter. Note that relays can be 12 V or 24 V capable.
Pic relay.png
Sch ord relay.png
1-Wire devices Digital thermometer DS1820 and TTJ100 connection to FMB20X
One of the implemented features on FMB20X is 1-Wire® data protocol, which enables connection to devices such as thermometer (DS1820, DS18S20 and DS18B20) and I-Button DS1990A.
Sch fmb20x ds1820.png
TTJ sensor pinout
Ttj fmb20x pinout.png
I-Button DS1990A connection to FMB20X
Sch fmb20x ibutton.png