Changes

no edit summary
Line 1: Line 1: −
<font size="+3"><span style=color:#104996>'''Mounting recommendations'''</span></font>
+
<font size="+2"><span style=color:#104996>'''Mounting recommendations'''</span></font>
 +
 
 +
<font size="+1"><span style=color:#F49E21> 1. </span> Connecting wires </font>
   −
<font size="+2"><span style=color:#F49E21> 1. </span> Connecting wires </font>
  −
<font size="+1">
   
* Wires should be connected while the module is not plugged in.
 
* Wires should be connected while the module is not plugged in.
 
* Wires should be fastened to stable wires or other non-moving parts. Any heat emitting and/or moving objects should be kept away from the wires.
 
* Wires should be fastened to stable wires or other non-moving parts. Any heat emitting and/or moving objects should be kept away from the wires.
Line 8: Line 8:  
* If the wires are placed in the exterior or in places where they can be damaged or exposed to heat, humidity, dirt, etc., additional isolation should be applied and the wires should not be loose.
 
* If the wires are placed in the exterior or in places where they can be damaged or exposed to heat, humidity, dirt, etc., additional isolation should be applied and the wires should not be loose.
 
* Wires cannot be connected to the board computers or control units.
 
* Wires cannot be connected to the board computers or control units.
</font>
+
<font size="+1"><span style=color:#F49E21> 2. </span> Connecting power source. </font>
<font size="+2"><span style=color:#F49E21> 2. </span> Connecting power source. </font>
  −
<font size="+1">
   
* Be sure that after the car computer goes to sleep mode, power might be still available on the power wires. Depending on the car model, this may happen in 5 to 30 minutes period.
 
* Be sure that after the car computer goes to sleep mode, power might be still available on the power wires. Depending on the car model, this may happen in 5 to 30 minutes period.
 
* When the module is connected, measure the voltage again to make sure it did not decrease.
 
* When the module is connected, measure the voltage again to make sure it did not decrease.
 
* It is recommended to connect to the main power cable in the fuse box.
 
* It is recommended to connect to the main power cable in the fuse box.
 
* 3 A, 125 V external fuse shall be used.
 
* 3 A, 125 V external fuse shall be used.
</font>
+
<font size="+1"><span style=color:#F49E21> 3. </span> Connecting ignition wire. </font>
<font size="+2"><span style=color:#F49E21> 3. </span> Connecting ignition wire. </font>
  −
<font size="+1">
   
* Be sure to check if it is a real ignition wire i. e. power does not disappear after starting the engine.
 
* Be sure to check if it is a real ignition wire i. e. power does not disappear after starting the engine.
 
* Check if this is not an ACC wire (when key is in the first position, most of the vehicle electronics are available).
 
* Check if this is not an ACC wire (when key is in the first position, most of the vehicle electronics are available).
 
* Check if power is still available when you turn off any of vehicles devices.
 
* Check if power is still available when you turn off any of vehicles devices.
 
* Ignition is connected to the ignition relay output. As alternative, any other relay, which has power output when ignition is on, may be chosen.
 
* Ignition is connected to the ignition relay output. As alternative, any other relay, which has power output when ignition is on, may be chosen.
</font>
+
<font size="+1"><span style=color:#F49E21> 4. </span> Connecting ground wire. </font>
<font size="+2"><span style=color:#F49E21> 4. </span> Connecting ground wire. </font>
  −
<font size="+1">
   
* Ground wire is connected to the vehicle frame or metal parts that are fixed to the frame.
 
* Ground wire is connected to the vehicle frame or metal parts that are fixed to the frame.
 
* If the wire is fixed with the bolt, the loop must be connected to the end of the wire.
 
* If the wire is fixed with the bolt, the loop must be connected to the end of the wire.
 
* For better contact scrub paint from the spot where loop is going to be connected.
 
* For better contact scrub paint from the spot where loop is going to be connected.
</font><br />
+
<br />
   −
<font size="+3"><span style=color:#104996>'''{{{model|FMB2YX}}} installation instruction'''</span></font><br>
+
<font size="+1"><span style=color:#104996>'''{{{model|FMB2YX}}} installation instruction'''</span></font><br>
   −
<font size="+1">
   
{{
 
{{
 
Template:FMB2YX_Installation_instruction
 
Template:FMB2YX_Installation_instruction
 
|model={{{model|FMB2YX}}}
 
|model={{{model|FMB2YX}}}
 
}}
 
}}
</font><br />
+
<br />
      Line 56: Line 49:  
<br /><br />
 
<br /><br />
   −
<font size="+3"><span style=color:#FF0000>'''Safety information'''</span></font><br/>
+
<font size="+1"><span style=color:#FF0000>'''Safety information'''</span></font><br/>
<font size="+2">
+
<font size="+1">
 
This message contains information on how to operate {{{model|FMB20X}}} safely. By following these requirements and recommendations, you will avoid dangerous situations. You must read these instructions carefully and follow them strictly before operating the device!<br/>
 
This message contains information on how to operate {{{model|FMB20X}}} safely. By following these requirements and recommendations, you will avoid dangerous situations. You must read these instructions carefully and follow them strictly before operating the device!<br/>
 
The device uses SELV limited power source. The device uses a 6 V...30 V DC power supply.
 
The device uses SELV limited power source. The device uses a 6 V...30 V DC power supply.
Line 65: Line 58:  
Before dismounting the device from the vehicle, the connection cables must be disconnected.<br/>
 
Before dismounting the device from the vehicle, the connection cables must be disconnected.<br/>
 
The device is designed to be mounted in a zone of limited access, which is inaccessible to the operator. All related devices must meet the requirements of EN 60950-1 standard.<br/>
 
The device is designed to be mounted in a zone of limited access, which is inaccessible to the operator. All related devices must meet the requirements of EN 60950-1 standard.<br/>
The device {{{model|FMB20X}}} is not designed as a navigational device for boats.<br/>
+
The device {{{model|FMB20X}}} is not designed as a navigational device for boats.<br/></font>
</font>
+
 
      −
<font size="+3"><span style=color:#104996>'''Precautions'''</span></font>
+
<font size="+1"><span style=color:#104996>'''Precautions'''</span></font>
<font size="+2">
   
{| class="wikitable" style="border-style: solid; border-width: 0px"
 
{| class="wikitable" style="border-style: solid; border-width: 0px"
 
|+  
 
|+  
Line 95: Line 87:  
| style="text-align: left; background: #F6F6FB;"        | Installation and/or handling during a lightning storm is prohibited.
 
| style="text-align: left; background: #F6F6FB;"        | Installation and/or handling during a lightning storm is prohibited.
 
|}
 
|}
</font>
 

Navigation menu