'''Note:''' when activated RS-485 driver chip draws a constant 30 mA current when entering Sleep or Deep sleep RS-485 will be powered off.
 
'''Note:''' when activated RS-485 driver chip draws a constant 30 mA current when entering Sleep or Deep sleep RS-485 will be powered off.
   −
==RS-485 modes==
+
===RS-485 modes===
 +
------------------
 
====RS-485 receive (FMB silent) mode====
 
====RS-485 receive (FMB silent) mode====
----------------------------------------
   
RS485 Works in receive mode. Support debug and testing commands. When the command is received answer is sent after that it back up to Receive mode.<br/>
 
RS485 Works in receive mode. Support debug and testing commands. When the command is received answer is sent after that it back up to Receive mode.<br/>
    
====RS-485 transmit (FMB log) mode====
 
====RS-485 transmit (FMB log) mode====
--------------------------------------
   
RS-485 prints the FMB device log and does not respond to commands.<br/>
 
RS-485 prints the FMB device log and does not respond to commands.<br/>
    
====RS-485 transmit (NMEA) mode====
 
====RS-485 transmit (NMEA) mode====
-----------------------------------
   
RS-485 prints GNSS NMEA log and does not respond to commands.<br/>
 
RS-485 prints GNSS NMEA log and does not respond to commands.<br/>
    
====RS-485 receive (LLS) mode====
 
====RS-485 receive (LLS) mode====
---------------------------------
   
This mode supports up to five [[{{{model|FMB640}}}_RS-232_and_RS-485#LLS_Sensor|LLS fuel level sensors]] each of which has a receiver ID.<br/>
 
This mode supports up to five [[{{{model|FMB640}}}_RS-232_and_RS-485#LLS_Sensor|LLS fuel level sensors]] each of which has a receiver ID.<br/>
    
====RS-485 TCP receive (ASCII/Binary) modes====
 
====RS-485 TCP receive (ASCII/Binary) modes====
-----------------------------------------------
   
In TCP ASCII/Binary mode a link with an external device using text messages can be established. Buffered modes save the information until a link with the server is established and records are sent.
 
In TCP ASCII/Binary mode a link with an external device using text messages can be established. Buffered modes save the information until a link with the server is established and records are sent.
    
====RS-485 receive (TCP ASCII/Binary Buffered) mode====
 
====RS-485 receive (TCP ASCII/Binary Buffered) mode====
-------------------------------------------------------
   
RS485 works in receive mode. When data received from server RS485 is switched to transmit mode. If the data server is not available, data will be saved in the buffer.
 
RS485 works in receive mode. When data received from server RS485 is switched to transmit mode. If the data server is not available, data will be saved in the buffer.
   Line 34: Line 29:  
[[image:FMX640 and RS232 illustration v1.2.png|800px|center]]
 
[[image:FMX640 and RS232 illustration v1.2.png|800px|center]]
   −
==RS-232 modes==
+
===RS-232 modes===
 +
------------------
 
Silent, Log mode, NMEA, LLS, TCP ASCII, and TCP Binary modes, TCP ASCII/Binary Buffered modes are identical to those of [[{{{model|FMB640}}}]] RS-232 and RS-485 modes.<br/>
 
Silent, Log mode, NMEA, LLS, TCP ASCII, and TCP Binary modes, TCP ASCII/Binary Buffered modes are identical to those of [[{{{model|FMB640}}}]] RS-232 and RS-485 modes.<br/>
 
'''Note:''' In RS-232 LLS mode only one LLS fuel level sensor can be connected.
 