Template:FMB964 Accessories

Bw nb.png Please order accessories separately as they are not included into device package.
Accessory and its description Accessory connection schematic
Alarm buttons, door sensors etc. Panic button connection to FMB9YX
Alarm buttons, door sensors, ignition, etc. have two output states: high or low. FMB9YX Digital inputs are used to detect these states.
Sch fmb1yx panic.png
Relays Inverting relay connection to FMB9YX
In cases when sensor output signal is negative, an additional relay has to be installed to convert negative signal to positive.
Sch fmb1yx inv relay.png
Immobilizer relay Immobilizer relay connection to FMB9YX output
When connected as shown on the right hand side, FMB9YX disables engine starter when output is ON.
Sch fmb1yx imb relay.png
Automotive relay Automotive relay pinout
An ordinary automotive relay is used to invert input signal or to immobilize engine starter. Note that relays can be 12 V or 24 V capable.
Pic relay.png
Sch ord relay.png