Changes

no edit summary
Line 167: Line 167:  
If ''DOUT Control'' is disabled, the scenario will only generate events without digital output activation. If ''DOUT Control'' is enabled {{{text_dout|DOUT1/DOUT2}}} turns ON if ignition turns ON (''Ignition Source'' is configured to 1). After any iButton ID (or RFID card) is attached, {{{text_dout|DOUT1/DOUT2}}} turns OFF. After iButton identification configured ''Ignition Source'' can be turned OFF (''Ignition Source'' is configured to 0) for no longer than 30 seconds, otherwise, the immobilizer must be repeated. If the ''iButton List Check'' parameter is enabled, the authorization will be successful only if the attached iButton is specified in the iButton list.<br/>
 
If ''DOUT Control'' is disabled, the scenario will only generate events without digital output activation. If ''DOUT Control'' is enabled {{{text_dout|DOUT1/DOUT2}}} turns ON if ignition turns ON (''Ignition Source'' is configured to 1). After any iButton ID (or RFID card) is attached, {{{text_dout|DOUT1/DOUT2}}} turns OFF. After iButton identification configured ''Ignition Source'' can be turned OFF (''Ignition Source'' is configured to 0) for no longer than 30 seconds, otherwise, the immobilizer must be repeated. If the ''iButton List Check'' parameter is enabled, the authorization will be successful only if the attached iButton is specified in the iButton list.<br/>
 
<br/><br/>
 
<br/><br/>
The ignition off timeout parameter is used to set the duration after which authorization is activated when the ignition is turned off. For example, if the Ignition off timeout is set to 30 seconds when the driver turns the ignition off, he has 30 seconds until the immobilizer security check turns on again. In other words, if the driver turns off the ignition and turns it back on in less than 30 seconds, then he will not have to attach the iButton to the reader again.
  −
      
From the firmware version '''[https://wiki.teltonika-gps.com/view/{{{model|FMB1YX}}}_firmware_errata 03.25.14]''' iBeacon authentication was introduced. iBeacon authentication works in the same way as iButton authentication. To use authorized iBeacons, the iBeacon list should be filled in the device configurator. Instructions how to list iBeacons in FMB devices can be found '''[https://wiki.teltonika-gps.com/view/{{{model|FMB1YX}}}_Beacon_List here]'''.
 
From the firmware version '''[https://wiki.teltonika-gps.com/view/{{{model|FMB1YX}}}_firmware_errata 03.25.14]''' iBeacon authentication was introduced. iBeacon authentication works in the same way as iButton authentication. To use authorized iBeacons, the iBeacon list should be filled in the device configurator. Instructions how to list iBeacons in FMB devices can be found '''[https://wiki.teltonika-gps.com/view/{{{model|FMB1YX}}}_Beacon_List here]'''.
Line 174: Line 172:  
By using iBeacon authorization, the immobilizer feature can be used with devices that don't have a 1-wire data connection available.
 
By using iBeacon authorization, the immobilizer feature can be used with devices that don't have a 1-wire data connection available.
 
<br/><br/><youtube>gjuiJjAejWU</youtube>}}}
 
<br/><br/><youtube>gjuiJjAejWU</youtube>}}}
 +
 +
The "Ignition Off Timeout" parameter is used to set the duration after which authorization is activated when the ignition is turned off. For example, if the Ignition off timeout is set to 30 seconds when the driver turns the ignition off, he has 30 seconds until the immobilizer security check turns on again. In other words, if the driver turns off the ignition and turns it back on in less than 30 seconds, then he will not have to attach the iButton to the reader again.
 +
 +
The "No Authentification Timeout" is used as a backup option in order to turn on the vehicle. For example if you set the "No Authentification Timeout" to 60 seconds, then you need to turn on the ignition and keep it active for 60 seconds, then the authorization will be successful (it will bypass the iBeacon or iButton authorization) and user will be able to turn on the vehicle on.
 +
 +
{{{seco_feature|==SECO==
 +
[[Image:SECO.png|right]]
 +
The solution, introduced in firmware version 03.28.02, is designed to stop a stolen vehicle without causing accidents. It accomplishes this by pulsing digital output to disable the fuel pump at intervals until the vehicle slows down to a configured speed, at which point the pump is fully disabled.<br />Parameters used with ''SECO'' functionality are given in a table below.
 +
 +
<table class="nd-othertables" style="width: 80%;">
 +
<tr>
 +
        <th style="width: 20%; text-align:left; vertical-align:middle; color:black">Parameter name</th>
 +
        <th style="width: 71%; text-align:center; vertical-align:middle; color:black">Description</th>
 +
        <th style="width: 9%; text-align:center; vertical-align:center; color:black">Parameter ID</th>
 +
    </tr>
 +
<tr>
 +
        <td style="width: 8%; text-align:left;">Scenario Settings</td>
 +
        <td style="width: 8%; text-align:left">Enable/Disable SECO functionality</td>
 +
        <td style="width: 8%; text-align:center">12250</td>
 +
    </tr>
 +
<tr>
 +
        <td style="width: 8%; text-align:left;">Eventual Records</td>
 +
        <td style="width: 8%; text-align:left">If disabled - scenario status value will be appended in each AVL record</td>
 +
        <td style="width: 8%; text-align:center">12251</td>
 +
    </tr>
 +
<tr>
 +
        <td style="width: 8%; text-align:left">Output Control</td>
 +
        <td style="width: 8%; text-align:left">Available scenario settings for module Digital output activation/deactivation</td>
 +
        <td style="width: 8%; text-align:center">12252</td> 
 +
    </tr>
 +
<tr>
 +
        <td style="width: 8%; text-align:left">Speed</td>
 +
        <td style="width: 8%; text-align:left">Digital output will be activated if vehicle speed consistently lower than configured during "Speed check period"</td>
 +
        <td style="width: 8%; text-align:center">12254</td>
 +
    </tr>
 +
<tr>
 +
        <td style="width: 8%; text-align:left">Speed Pulse scenario</td>
 +
        <td style="width: 8%; text-align:left">Valid if "Output Pulse" feature enabled. Scenario will be activated if vehicle speed consistently lower than configured during "Speed check period". After activation digital output will be activated and disabled continuously until speed will be lower then configured in "Speed" field and longer then "Speed check period"</td>
 +
        <td style="width: 8%; text-align:center">12259</td>
 +
    </tr>
 +
<tr>
 +
        <td style="width: 8%; text-align:left">Speed check period</td>
 +
        <td style="width: 8%; text-align:left">Time span during which vehicle speed must be lower than configured for output to activate.</td>
 +
        <td style="width: 8%; text-align:center">12255</td>
 +
    </tr>
 +
<tr>
 +
        <td style="width: 8%; text-align:left">Momevemt timeout</td>
 +
        <td style="width: 8%; text-align:left">Accelerometer's instant movement timeout after which output will be activated (GNSS OFF)</td>
 +
        <td style="width: 8%; text-align:center">12256</td>
 +
    </tr>
 +
<tr>
 +
        <td style="width: 8%; text-align:left">Output pulse</td>
 +
        <td style="width: 8%; text-align:left">Pulse scenario adds additional output control which helps to slow down vehicle before fully disabling fuel pump.</td>
 +
        <td style="width: 8%; text-align:center">12253</td>
 +
    </tr>
 +
<tr>
 +
        <td style="width: 8%; text-align:left">DOUT ON duration</td>
 +
        <td style="width: 8%; text-align:left">A value in milliseconds, for how long DOUT should be active</td>
 +
        <td style="width: 8%; text-align:center">12257</td>
 +
    </tr>
 +
<tr>
 +
        <td style="width: 8%; text-align:left">DOUT OFF duration</td>
 +
        <td style="width: 8%; text-align:left">A value in milliseconds, for how long DOUT should be inactive</td>
 +
        <td style="width: 8%; text-align:center">12258</td>
 +
    </tr>
 +
</table>
 +
 +
===SECO SMS Commands===
 +
 +
Secure engine cut-off (SECO) functionality is available for device with at least one DOUT.  For SECO functionality to work, DOUT must to be selected. SECO has DOUT control priority higher than immobilizer scenario.<br>
 +
SECO scenario can only be enabled or disabled by SMS commands:<br>
 +
*"secoon" - to activate SECO functionality.
 +
 +
*"secooff" - to disable SECO functionality.
 +
The structure of sending SMS commands: [[FMB130 SMS/GPRS Commands]]
 +
 +
==== 1. SMS responses====
 +
 +
To SMS command „secooff“ device will give response: „Seco off received. DOUTX off“.
 +
 +
To SMS command „secoon“ response:
 +
 +
1. „Seco on received. Waiting for conditions“.
 +
 +
2. „Seco on received. DOUTX pulsing“.
 +
 +
3. „Seco on received. DOUTX on“.
 +
 +
When response is not 3 all later SMS will be received. Example: SMS 1 received and pulse configured, then SMS 2 will be received when speed is lower than configured and SMS 3 will be received when speed reaches 0 km/h. <br>
 +
'''Note:'''
 +
Sending commands to the device without DOUT will give response "SECO not available for this device". When DOUT is not selected in configuration response will be: "Error. no DOUT configured". This secure vehicle disabling solution is supported by any Teltonika FMB series tracker (excluding FMX640 series trackers), also SIM card is in order to get data to your server.
 +
 +
For more information about SECO configuring please see [https://wiki.teltonika-gps.com/view/Secure_vehicle_disabling '''here''']
 +
 +
}}}
    
{{{ibutton_feature|==iButton Read Notification==
 
{{{ibutton_feature|==iButton Read Notification==
Line 192: Line 285:  
*iButton List checking - parameter configures that device reads the iButton ID from list or not.
 
*iButton List checking - parameter configures that device reads the iButton ID from list or not.
 
*Depend on Ignition - Output will be triggered only if ignition is off
 
*Depend on Ignition - Output will be triggered only if ignition is off
<br/><br/>}}}
+
}}}
    
{{{gnss_fuel|
 