Difference between revisions of "Template:FMM640 CAN adapters"

From Wiki Knowledge Base | Teltonika GPS
Line 22: Line 22:
 
|-
 
|-
 
|}
 
|}
 
==SIMPLE-CAN - contactless CAN-BUS reader==
 
 
[[Image:FMB640_simplecan.png|300px|right]]
 
SIMPLE-CAN is a contactless adapter used to read vehicle CAN data with LV-CAN200 or ALL-CAN300. If LV-CAN200 or ALL-CAN300 connection requires two CAN lines to get all data, then two SIMPLE-CAN readers are required.
 
 
<font size="+1">Technical details</font>
 
* Power supply voltage +9..+63 V.
 
* Power supply current: standby 1.6 mA, active 8.3 mA @ 12 V; standby 0.91 mA, active 4.3 mA @ 24 V.
 
* CAN-BUS speeds from 33.33 to 500 kb/s.
 
* Automatically sets CAN Low, CAN High polarity.
 
* Automatically adjusts signal level and speed.<br/><br/>
 
 
SIMPLE-CAN works in the '''listening mode only''', so that not all the data available on the CAN-BUS may be received using this solution. '''The device automatically sets CAN L/H polarity''', but the calibration has to be always performed during installation process. Connection of previously calibrated unit to another car needs new calibration because the reader '''automatically adjusts signal level and speed''' to different CAN buses. The device also '''automatically adapts''' to the found '''noise level'''.
 
 
[[Image:FMB640_simplecan_pinout.png|800px|none]]
 
 
When power supply is connected, the LED shines continuously. It means that device is waiting for calibration. '''Calibration process''' has to be carried out when CAN-BUS twisted pair is tightened on SIMPLE-CAN and when ignition is ON. Please press the switch briefly and wait for the LED to start blinking every second. Automatic calibration process takes up to 10 seconds depending on the vehicle's model. Correct calibration process is confirmed by LED starting to blink every 2 seconds (when the CAN-BUS is active). When the CAN-BUS enters sleep mode, SIMPLE-CAN device also enters sleep mode and takes 1.6mA @ 12V. In the sleep mode LED does not shine. If after calibration process LED shines continuously, it means that device is not calibrated yet, CAN-BUS transmission has failed or ignition during calibration was not ON.
 
 
==LV-CAN200 and ALL-CAN300 program number selection==
 
LV-CAN200 or ALL-CAN300 must be set to program number which depends on the vehicle model. '''Needed program number is always written on LV-CAN200 or ALL-CAN300 mounting scheme.''' Please contact Teltonika sales manager to get the latest supported vehicle list and mounting scheme for your vehicle providing information about car manufacturer, model and year.
 
 
===LV-CAN200 and ALL-CAN300 program number configuration via SMS command===
 
----
 
LV-CAN200 and ALL-CAN300 program number can be set remotely, using SMS command, where X is new program number value:<br/>''"lvcansetprog X"''<br/>
 
 
===Selecting LV-CAN200 and ALL-CAN300 program number manually===
 
----
 
 
[[Image:FMB640_adapter_led.png|300px|right]]
 
Steps to set program number:
 
* Hold SWITCH down until LED stars blinking.
 
* Release the SWITCH.
 
* Then LED starts blinking and counting first digit of program number (one blink means digit 1, two blinks mean digit 2 etc).
 
* To stop counter push SWITCH.
 
* Release the SWITCH, then LED starts blinking and counting second digit of program number.
 
* To stop counter push SWITCH.
 
* Release the SWITCH, then LED starts blinking and counting third digit on program number.
 
* To stop counter push SWITCH.
 
* Release SWITCH, if programming is successful LED will blink 10 times.
 

Revision as of 08:53, 26 August 2019

Purpose of CAN adapters LV-CAN200 and ALL-CAN300

FMB640 can connx diagram.png

LV-CAN200 is used to read data from light vehicles, while ALL-CAN300 is used to read data from any type of transport: light vehicles, trucks, buses, agriculture transport and other special transport. Using these adapters FMB640 device is able to collect and send vehicle data.

Parameter Value
Supply voltage +9..+50 V
Power supply current Average 10 mA. Max (peak) 100 mA
Working temperature -40..+85 ºC
Max working humidity 60 % (non condensate).