===Connecting Iridium device to {{{device|}}}===
 
===Connecting Iridium device to {{{device|}}}===
 +
In order to properly connect Iridium device to {{{device|}}}, Iridium has to be connect via RS-232 COM1 or COM2. Also PIN6 - power control (reference in image below) has to be connected to one of the {{{device|}}} DOUTs, in order to allow device to power ON/OFF Iridium device on demand.
    +
 +
 +
 +
{| class="wikitable"
 +
|- style="font-weight:bold; text-align:center;"
 +
! <br />Pin. No
 +
! <br />Signal name
 +
! <br />Signal  direction (with respect to Iridium Edge)
 +
! <br />Description
 +
|-
 +
| <br />1
 +
| <br />Spare
 +
| <br />-
 +
| <br />Unused
 +
|-
 +
| <br />2
 +
| <br />Ground
 +
| <br />Input
 +
| <br />Signal and power GND
 +
|-
 +
| <br />3
 +
| <br />RS232_RX
 +
| <br />Input
 +
| <br />RS232 input
 +
|-
 +
| <br />4
 +
| <br />RS232_TX
 +
| <br />Output
 +
| <br />RS232 output
 +
|-
 +
| <br />5
 +
| <br />Power
 +
| <br />Input
 +
| <br />9-32 V positive terminal
 +
|-
 +
| <br />6
 +
| <br />ON/OFF
 +
| <br />Input
 +
| <br />Optional line to power down Iridium edge
 +
|-
 +
| <br />7
 +
| <br />Network available
 +
| <br />Output
 +
| <br />
 +
|-
 +
| <br />8
 +
| <br />Power detectection
 +
| <br />Output
 +
| <br />Active high then Iridium Edge is powered
 +
|}
    